Adamczewski offers industrial users an extensive product range, which reaches from isolation amplifiers to processor controlled frequency measuring converters. Experience over decades in measuring and automation technology, co-operation with users in the area of research, supply of water, electricity and gas, as well as production and house technology, determine optimal product architecture and innovative system technology.
stands for customer specific solutions and branch know-how in the area of frequency and impulse technology as well as measuring value amplifiers and numerous special devices. Advice and support for the technically as well as the economically adequate system, and the knowledge, training level, creativity and motivation of employees are the best preconditions for a successful dialogue
Adamczewski Measuring products
Excerpt out of our productprogramm:
Manufacturer :Adamczewski
Product : Isolation Amplifier
Limit-Monitor, Limit-Switch, Voltage-Monitor,
Phase-Monitoring, Load-Monitoring
signalling and controlling of limits
Limit-Switch
|
input
|
output
|
power supply
|
AD-MK 330 GS
Standard-Limit-Switch
function free selectable
|
0...20mA, 4...20mA, 0...10V
free selectable
|
2x changeover contact
operating principle adjustable
|
broad range
20..253VDC,
50..253VAC
|
AD-MK 340 GVD
Standard-Limit-Switch
function free selectable
|
0...20mA, 4...20mA, 0...10V
free selectable
|
2x changeover contact
operating principle adjustable
|
broad range
20..253VDC,
50..253VAC
|
AD-MK 350 GVD
VarioControl/-Connect compatible
AD-Studio configurable
|
0...20mA, 4...20mA (max. ±50mA)
0...10V (max. ±100VDC)
transmitter supply
RTD: Pt, Ni
|
2x changeover contact
freely configurable
|
broad range
20...253VDC,
50...253VAC
|
AD-SMK 330 GS
Feeder-Measuring-Contact
with integr. transmitter supply
|
4...20mA with
2-/3-wire- transmitter supply
|
2x changeover contact
operating principle adjustable
|
broad range
20..253VDC,
50..253VAC
|
AD-SMK 340 GVD
Feeder-Measuring-Contact
with integr. transmitter supply
|
4...20mA with
2-/3-wire- transmitter supply
|
2x changeover contact
operating principle adjustable
|
broad range
20..253VDC,
50..253VAC
|
|
Voltage-, Phase-, Load-
Montoring
|
input
|
output
|
power-supply
|
AD-UW 60 GT
3-phase voltage monitor
|
80...253VAC
|
1x changeover contact
|
via input
|
AD-LW 110 GS
load-monotoring for
low-voltage and cos(phi)
|
L1/L2/L3 to N
1x max 5AAC (L1)
3x 230VAC
|
1x NO contact for low-voltage
1x NO contact for cos(phi)
|
broad-range
20...253VDC,
50...253VAC
|
|
Multifunction
|
input
|
output
|
power-supply
|
AD-VC1GVD-R2
VarioControl/-Connect compatible
AD-Studio configurable
|
- max. ±24mA, 12V, ±250mV
- ransmitter supply
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- potentiometer (3-wire)
|
2 outputs (analog)
max. 20mA, 10V (also bipolar)
2 outputs (digital)
relay contacts (change-over)
|
broad range
20...253VDC,
50...253VAC
|
Manufacturer :Adamczewski
Product :Supply Isolation Amplifier
Supply Isolation Amplifier
type
|
input
|
output
|
power supply
|
AD-STV 2 GX
6,2mm
Supply Isolation Amplifier
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
1:1 to input
|
18...30VDC also via
DIN rail connector
|
AD-STV 24 GVB
Supply Isolation Amplifier
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
1:1 to input
|
11...30VDC
|
AD-STV 24 GL
Supply Isolation Amplifier
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
1:1 to input
|
11...30VDC
|
AD-STV 22 GVB
Supply Isolation Amplifier
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
1:1 to input
|
broad-range
20...253VDC,
50...253VAC
|
AD-STV 22 GL
Supply Isolation Amplifier
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
1:1 to input
|
broad-range
20...253VDC,
50...253VAC
|
AD-STV 40 GVC
Supply Isolation Amplifier
standard-signals selectable
AD-Studio configurable
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
0...20mA, 4...20mA, 0...10V
(freely selectable)
|
broad-range
20...253VDC,
50...253VAC
|
AD-STH 40 GVC
HART-Supply Isolation Amplifier
with frequenz shift keying
(like HART-Protocol)
AD-Studio configurable
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
0...20mA, 4...20mA, 0...10V
(freely selectable)
|
broad-range
20...253VDC,
50...253VAC
|
AD-TV 400 GVD
VarioControl/-Connect compatible
AD-Studio configurable
|
2-/3-wire-transmitters
max. ±50mA
max. ±100VDC
|
1x max. ±20mA or ±10V
1x current sink max. 20mA
|
broad range
20...253VDC,
50...253VAC
|
AD-TV 420 GVD
VarioControl/-Connect compatible
AD-Studio configurable
|
2-/3-wire-transmitters
max. ±50mA
max. ±100VDC
|
2x max. ±20mA or ±10V
|
broad range
20...253VDC,
50...253VAC
|
AD-STV 300 GS
Universal
Supply Isolation Amplifier
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
0...20mA, 4...20mA, 0...10VC
(free selectable)
|
broad-range
20...253VDC,
50...253VAC
|
AD-TV 320 GS
Setpoint-Isolation-Amplifier
with remote activation,
call back, contact and
transmitter supply
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
0...20mA, 4...20mA, 0...10V
(1:1 to input or as setpoint)
|
broad-range
20...253VDC,
50...253VAC
|
AD-STV 810 GS
Supply Isolation Amplifier
up to max. 20 kHz (-3dB)
|
2-/3-wire-transmitters
0...20mA, 4...20mA
|
+/-20mA or +/-10V
to specify by order
|
broad-range
20...253VDC,
50...253VAC
|
Manufacturer :Adamczewski
Product :Ex-Components
Ex-Components
type
|
input
|
output
|
power supply
|
Ex-Supply Isolation Amplifier
AD-STVEX 710 GVD
II (1)G [Ex ia Ga] IIC
II (1)D [Ex ia Da] IIIC
AD-Studio configurable
|
2-wire-transmitter or activ
0...20mA, 4...20mA or 0...10V
with Ex-input terminal below
(ordering option S-488)
|
0...20mA, 4...20mA, 0...10V
freely programmable (max. 20mA/10V)
|
broad range
20-120VDC,
50-250VAC
|
Ex-Contact-Amplifier
AD-KVEX 100 GVD (1-channel)
AD-KVEX 200 GVD (2-channel)
II (1)G [Ex ia Ga] IIC
II (1)D [Ex ia Da] IIIC
|
contact / NAMUR-sensor
with Ex-input terminal below
(ordering option S-488)
|
relay contact
or optional also as
semi-conductor relay
|
broad range
20-120VDC,
50-250VAC
|
Manufacturer :Adamczewski
Product :AC Isolation Amplifier
AC-Isolation Amplifier
electrically isolation, transform, amplify
type
|
input
|
output
|
power supply
|
AD-SWT 50
AD-SWT 100
AD-SWT 200
Current-Transformer-Transmitter
|
50AAC
100AAC
200AAC
clamp-on transformer technology
|
4...20mA
2-wire transmitter
|
transmitter supply
10...30VDC
(on output side)
|
AD-SWT 50 TRMS
AD-SWT 100 TRMS
AD-SWT 200 TRMS
Current-Transformer-Transmitter
true RMS-measurement
|
50AAC
100AAC
200AAC
clamp-on transformer technology
|
4...20mA
2-wire transmitter
true-rms-measurement
|
transmitter supply
10...30VDC
(on output side)
|
AD-TV 515 GS (analogue)
AC-Isolation Amplifier
|
0...1AAC, 0...5AAC
selectable over terminal
|
0...20mA, 4...20mA, 0...10V
(acc. to order specifications)
|
broad range
20...253VDC,
50...253VAC
|
AD-TV 561 GS (analogue)
AC-Isolation Amplifier
|
max. 0...600VAC
(acc. to order specifications)
|
0...20mA, 4...20mA, 0...10V
(acc. to order specifications)
|
broad range
20...253VDC,
50...253VAC
|
AD-TV 581 GS (digital)
Vario AC-Isolation Amplifier
|
0...1AAC, 0...5AAC
selectable over terminal
|
0...20mA, 4...20mA, 0...10V
true-rms-measurement
|
broad range
20...253VDC,
50...253VAC
|
AD-TV 591 GS (digital)
Vario AC-Isolation Amplifier
|
0...250VAC, 0...450VAC
selectable over terminal
|
0...20mA, 4...20mA, 0...10V
true-rms-measurement
|
broad range
20...253VDC,
50...253VAC
|
AD-TV 588 GVD (digital)
AC-Isolation Amplifier
VarioControl/-Connect compatible
AD-Studio configurable
|
from split core transformer
up to 600 A (AD-KSW)
or directly connected
0...1AAC, 0...5AAC
|
0...20mA, 4... 20mA, 0...10V,
relay (N/O) for limit values
|
broad range
20...253VDC,
50...253VAC
|
AD-SW 3 GL
Current-Transformer
|
3x alternating currents up
to max.10AAC
(bushing transformer principle)
|
3x 0...10VAC
|
broad range
20...253VDC,
50...253VAC
|
AD-SWK 3
Current-Transformer
in folding technique
|
3x alternating currents up
to max.10AAC
(bushing transformer principle)
|
3x 0...10VAC
|
broad range
20...253VDC,
50...253VAC
|
Manufacturer :Adamczewski
Product :Isolation Converter
DC-Isolation Converter
electrically isolated and convert without power-supply
type
|
input
|
output
|
power supply
|
AD-TW 41 GM
AD-TW 41 ST
(1-channel)
Isolation Converter
|
0...20mA, 4...20mA
|
1:1 to input
|
not necessary
|
AD-TW 42 GS
(2-channel)
Isolation Converter
|
0...20mA, 4...20mA
|
1:1 to input
|
not necessary
|
AD-TW 201 GS
AD-TW 201 ST
ADTW 201 MO
(1-channel)
Isolation Converter
|
0...20mA, 4...20mA
|
1:1 to input
(only 500 Ohm)
|
not necessary
|
AD-TW 202 GS
(2-channel)
Isolation Converter
|
0...20mA, 4...20mA
|
1:1 to input
(only 500 Ohm)
|
not necessary
|
AD-TWH 41 GM
AD-TWH 41 ST
(1-channel)
Isolation Converter with HART
|
0...20mA, 4...20mA
|
1:1 to input
|
not necessary
|
Manufacturer :Adamczewski
Product :AC Isolation Converter
AC-Isolation-Converter
electrically isolated and convert without power-supply
type
|
input
|
output
|
power supply
|
AD-SWT 50
AD-SWT 100
AD-SWT 200
current-transformer-transmitter
|
50AAC
100AAC
200AAC
clamp-on transformer
|
2-wire transmitter
4...20mA (current sink)
|
10...30VDC
(on output side)
|
AD-SWT 50 TRMS
AD-SWT 100 TRMS
AD-SWT 200 TRMS
current-transformer-transmitter
true-RMS-measurment
|
50AAC
100AAC
200AAC
clamp-on transformer
|
2-wire transmitter
4...20mA (current sink)
true-RMS-measurment
|
10...30VDC
(on output side)
|
AD-TW 21 GVD (1-channel)
AC-Isolation-Converter
|
0...1A (50Hz, sine)
|
0...20mA
|
not necessary
|
AD-TW 25 GVD (1-channel)
AC-Isolation-Converter
|
0...5A (50Hz, sine)
|
0...20mA
|
not necessary
|
Manufacturer :Adamczewski
Product :"VarioControl" compatible devices
programmable signal converter with detachable LCD display
VarioControl, VarioConnect compatible device overview
VarioControl register of all current compatible devices
indicating & operating
|
feature
|
AD-VarioControl
|
- LCD for display of different operating modes, lit in several colours (R/Y/B)
- to configure the device parameters
- also for backup and restoration of device parameters
- pluggable or removable even during operation (hot-plugged)
|
AD-VarioConnect
(with integrated RS485-interface)
|
like VarioControl, but additionally with integrated RS485 interface
(protocol: Modbus RTU)
|
|
isolation amplifier
|
input
|
output
|
power-supply
|
AD-TV 400 GVD
AD-Studio configurable
|
max. ±50 mA
max. ±100VDC
|
1x max. ±20mA or ±10V
1x current sink max. 20 mA
both outputs freely configurable
|
broad range
20...253VDC,
50...253VAC
|
AD-TV 420 GVD
AD-Studio configurable
|
max. ±50 mA
max. ±100VDC
|
2x max. ±20mA or ±10V
both outputs freely configurable
|
broad range
20...253VDC,
50...253VAC
|
|
AC-isolation amplifier
|
input
|
output
|
power-supply
|
AD-TV 588 GVD
AD-Studio configurable
|
Split-Core Transformer
up to 600 A (AD-KSW)
or directly connected
0...1 AAC, 0...5 AAC
|
0...20 mA, 4... 20mA, 0...10 V,
relay (N/O) for limit values
|
broad range
20...253 VDC,
50...253 VAC
|
|
temperture-converter
|
input
|
output
|
power-supply
|
AD-MV 550 GVD
AD-Studio configurable
|
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- 144 mV
|
- max. ±20mA or ±10V
- current-sink max. 20 mA
|
broad range
20...253VDC,
50...253VAC
|
|
limit-switch
|
input
|
output
|
power-supply
|
AD-MK 350 GVD
AD-Studio configurable
|
- max. ±50 mA
- max. ±100VDC
- transmitter supply
- RTD: Pt, Ni
|
- 2x relay contacts (C/O)
|
broad range
20...253VDC,
50...253VAC
|
|
multifunction
|
input
|
output
|
power-supply
|
AD-VC1GVD-R0
AD-Studio configurable
|
- max. ±24mA, 12V, ±250mV
- ransmitter supply
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- potentiometer (3-wire)
|
2 outputs (analog)
max. ±20mA, ±10V
|
broad range
20...253VDC,
50...253VAC
|
AD-VC1GVD-R2
AD-Studio configurable
|
- max. ±24mA, 12V, ±250mV
- ransmitter supply
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- potentiometer (3-wire)
|
2 outputs (analog)
max. ±20mA, ±10V
2 outputs (digital)
relay contacts (C/O)
|
broad range
20...253VDC,
50...253VAC
|
|
frequency-converter
|
input
|
output
|
power-supply
|
AD-FM 255 GVD
AD-Studio configurable
|
0...0,01Hz to 0...10kHz
NAMUR, contact, open-
collector, 24V-activ i.a.
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
Output 3: contact (C/O)
(optionally also as semiconductor)
|
broad range
20...253VDC,
50...253VAC
|
|
power-meter
|
input
|
output
|
power-supply
|
AD-LU 320 GVD (1-phase)
AD-Studio configurable
|
1x 1/5A (253VAC)
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 325 GVD (1-phase)
AD-Studio configurable
|
1x max. 600A / 253VAC
via external push-through
current transformer
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 620 GVD (3-phase)
AD-Studio configurable
|
3x 1/5A (253VAC)
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
Output 3: contact (N/O)
Output 4: semiconductor
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 625 GVD (3-phase)
AD-Studio configurable
|
3x max. 600A / 253VAC
via external push-through
current transformer
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
Output 3: contact (N/O)
Output 4: semiconductor
|
broad-range
20...253VDC,
50...253VAC
|
Manufacturer :Adamczewski
Product :Transmitter, Isolation Transmitter
Isolation-Transmitter
electrically isolated and convert without power-supply
transmitter
|
input
|
output
|
power supply
|
AD-MWT 21 ST (2-wire-passiv)
value-transmitter active
|
0...10VDC
|
2-wire transmitter
4...20mA (current sink)
|
8...32VDC
(on output side)
|
AD-MWT 22 ST (2-wire-passiv)
value-transmitter active
|
0...20mA
|
2-wire transmitter
4...20mA (current sink)
|
8...32VDC
(on output side)
|
AD-MWT 24 ST (2-wire-passiv)
value-transmitter active
|
4...20mA
|
2-wire transmitter
4...20mA (current sink)
|
8...32VDC
(on output side)
|
AD-MWT 50 ST
Pt-100 value-transmitter
|
Pt-100 (3-wire)
range acc. to user data
|
2-wire transmitter
4...20mA (current sink)
|
8...32VDC
(on output side)
|
|
isolation transmitter
|
input
|
output
|
power supply
|
AD-SWT 50
AD-SWT 100
AD-SWT 200
current-transformer-transmitter
|
50AAC
100AAC
200AAC
push-through transformer
|
2-wire transmitter
4...20mA (current sink)
|
10...30VDC
(on output side)
|
AD-SWT 50 TRMS
AD-SWT 100 TRMS
AD-SWT 200 TRMS
current-transformer-transmitter
true-RMS-measurment
|
50AAC
100AAC
200AAC
push-through transformer
|
2-wire transmitter
4...20mA (current sink)
true-RMS-measurment
|
10...30VDC
(on output side)
|
AD-TWT 24 GM
Isolation-Transmitter
|
4...20mA
|
2-wire transmitter
4...20mA (current sink)
|
8...32VDC
(on output side)
|
Manufacturer :Adamczewski
Product :Measuring Converter and VarioCheck
for temperature (Pt100 / 1000, thermocouples etc.), potentiometers
Measuring Transducer, Converter - VarioCheck
for Potentiometer, levels, Temperature
VarioControl devices
|
input
|
output
|
power-supply
|
AD-MV 550 GVD
VarioControl/-Connect compatible
AD-Studio configurable
|
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- 144 mV
|
- max. ±20mA or ±10V
- current-sink max. 20mA
|
broad range
20...253VDC,
50...253VAC
|
AD-VC1GVD-R0 (0 contact output)
AD-VC1GVD-R2 (2 contact output)
VarioControl/-Connect compatible
AD-Studio configurable
|
- max. ±24mA, 12V, ±250mV
- ransmitter supply
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- potentiometer (3-wire)
|
2 outputs (analog)
max. ±20mA, ±10V
2 outputs (digital)
relay contacts (change-over)
|
broad range
20...253VDC,
50...253VAC
|
|
VarioCheck for DIN-rail
|
input
|
output
|
power supply
|
VarioCheck 3
AD-VC3GF-R0 (0 contact output)
AD-VC3GF-R2 (2 contact output)
AD-VC3GF-R4 (4 contact output)
AD-Studio configurable
|
- current max.20mA
- voltage max.10V
- potentiometer
- 2/3-wire transmitter
|
2 parallel output:
- current (max.20mA)
- voltage (max.10V)
contact output: max. 4 relay (C/O)
|
broad range
20..253VDC,
50..253VAC
|
VarioCheck 3
AD-VC3GVF-R0 (0 contact output)
AD-VC3GVF-R2 (2 contact output)
AD-VC3GVF-R4 (4 contact output)
AD-Studio configurable
|
- current max.20mA
- voltage max.10V
- potentiometer
- 2/3-wire transmitter
|
2 parallel output:
- current (max.20mA)
- voltage (max.10V)
contact output: max. 4 relay (C/O)
|
broad range
20..253VDC,
50..253VAC
|
VarioCheck 3
AD-VC3B GVF-R0 (0 contact output)
AD-VC3B GVF-R2 (2 contact output)
AD-VC3B GVF-R4 (4 contact output)
AD-Studio configurable
|
Device design as previously, but without display and configuration keys.
Programming only via optional AD-Studio software
|
VarioCheck for DIN-rail
|
input
|
output
|
power supply
|
VarioCheck 5
AD-VC5GVF-R0 (0 contact output)
AD-VC5GVF-R2 (2 contact output)
AD-VC5GVF-R4 (4 contact output)
AD-Studio configurable
|
- resistance thermometer
Pt100, 500, 1000
Ni100, 500, 1000
- thermocouples
type: J,T,K,E,N,S,R,B
|
2 parallel output:
- current (max.20mA)
- voltage (max. 10V)
contact output: max. 4 relay (C/O)
|
broad range
20..253VDC,
50..253VAC
|
VarioCheck 5
AD-VC5B GVF-R0 (0 contact output)
AD-VC5B GVF-R2 (2 contact output)
AD-VC5B GVF-R4 (4 contact output)
AD-Studio configurable
|
Device design as previously, but without display and configuration keys.
Programming only via optional AD-Studio software
|
VarioCheck
for front-panel mounting
|
input
|
output
|
power supply
|
VarioCheck 4
AD-VC4S R0 (0 contact output)
AD-VC4S R2 (2 contact output)
AD-VC4S R4 (4 contact output)
AD-Studio configurable
|
- current (max.20mA)
- voltage (max.10V)
- potentiometer
- 2/3-wire transmitter
|
2 parallel output:
- current (max.20mA)
- voltage (max.10V)*
contact output: max. 4 relay (C/O)
(*only version R2 and R4)
|
broad range
20..253VDC,
50..253VAC
|
type
|
input
|
output
|
power supply
|
AD-MV 110 GS
measuring transducer
for potentiometer
|
0-100 to 0-100kOhm
|
0...20mA, 4...20mA, 0...10V
(to specify by order)
|
broad range
20..253VDC,
50..253VAC
|
AD-MV 50 GX
2/3-wire Pt-100 converter
|
Pt-100
(range acc. to user data)
|
0...20mA, 4...20mA, 0...10V
(to specify by order)
|
18...30VDC opt.
also via DIN rail
connector
|
AD-MV 54 GX
4-wire Pt-100 converter
|
Pt-100
(range acc. to user data)
|
0...20mA, 4...20mA, 0...10V
(to specify by order)
|
18-30VDC opt.
also via DIN rail
connector
|
AD-MV 50 GL
2/3-wire Pt-100 converter
|
Pt-100
(range acc. to user data)
|
0...20mA, 4...20mA, 0...10V
(to specify by order)
|
broad range
20..253VDC,
50..253VAC
|
AD-MV 54 GL
4-wire Pt-100 converter
|
Pt-100
(range acc. to user data)
|
0...20mA, 4...20mA, 0...10V
(to specify by order)
|
broad range
20..253VDC,
50..253VAC
|
AD-MV 55 GX
RS485-Converter
(1 temperature signal input)
AD-Studio configurable
|
temperature signal
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- 144 mV
|
RS485 (modbus-RTU)
connector compatible
|
18..30VDC
connector compatible
|
AD-MV 500 GL
electr. isolated
2/3/4-wire Pt-100 converter
|
Pt-100
(range acc. to user data)
|
0...20mA, 4...20mA, 0...10V
(to specify by order)
|
broad range
20..253VDC,
50..253VAC
|
AD-MW 200 ST
measuring transducer
not electrically isolated
|
0...20mA, 4...20mA, 0...10V
(to specify by order)
|
0...20mA, 4...20mA, 0...10V
(to specify by order)
|
20...30VDC
|
Manufacturer :Adamczewski
Product :Limit Switch, Limit Monitor and Monitoring
Limit-Monitor, Limit-Switch, Voltage-Monitor,
Phase-Monitoring, Load-Monitoring
signalling and controlling of limits
Limit-Switch
|
input
|
output
|
power supply
|
AD-MK 330 GS
Standard-Limit-Switch
function free selectable
|
0...20mA, 4...20mA, 0...10V
free selectable
|
2x changeover contact
operating principle adjustable
|
broad range
20..253VDC,
50..253VAC
|
AD-MK 340 GVD
Standard-Limit-Switch
function free selectable
|
0...20mA, 4...20mA, 0...10V
free selectable
|
2x changeover contact
operating principle adjustable
|
broad range
20..253VDC,
50..253VAC
|
AD-MK 350 GVD
VarioControl/-Connect compatible
AD-Studio configurable
|
0...20mA, 4...20mA (max. ±50mA)
0...10V (max. ±100VDC)
transmitter supply
RTD: Pt, Ni
|
2x changeover contact
freely configurable
|
broad range
20...253VDC,
50...253VAC
|
AD-SMK 330 GS
Feeder-Measuring-Contact
with integr. transmitter supply
|
4...20mA with
2-/3-wire- transmitter supply
|
2x changeover contact
operating principle adjustable
|
broad range
20..253VDC,
50..253VAC
|
AD-SMK 340 GVD
Feeder-Measuring-Contact
with integr. transmitter supply
|
4...20mA with
2-/3-wire- transmitter supply
|
2x changeover contact
operating principle adjustable
|
broad range
20..253VDC,
50..253VAC
|
|
Voltage-, Phase-, Load-
Montoring
|
input
|
output
|
power-supply
|
AD-UW 60 GT
3-phase voltage monitor
|
80...253VAC
|
1x changeover contact
|
via input
|
AD-LW 110 GS
load-monotoring for
low-voltage and cos(phi)
|
L1/L2/L3 to N
1x max 5AAC (L1)
3x 230VAC
|
1x NO contact for low-voltage
1x NO contact for cos(phi)
|
broad-range
20...253VDC,
50...253VAC
|
|
Multifunction
|
input
|
output
|
power-supply
|
AD-VC1GVD-R2
VarioControl/-Connect compatible
AD-Studio configurable
|
- max. ±24mA, 12V, ±250mV
- ransmitter supply
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- potentiometer (3-wire)
|
2 outputs (analog)
max. 20mA, 10V (also bipolar)
2 outputs (digital)
relay contacts (change-over)
|
broad range
20...253VDC,
50...253VAC
|
Manufacturer :Adamczewski
Product :Indicating & Operating (VarioShow, VarioLog, VarioControl etc.)
display, operate, configure or log data
"VarioShow" Indicators and "VarioLog" data logger
panel-mount-case (48x96mm), programmable, interface, LCD-Display
indicator
|
input
|
output
|
power supply
|
VarioShow AD-VS8 indicator
AD-Studio configurable
|
current (max.20mA),
voltage (max.10V)
|
1-channel (type AD-VS8A1)
4-channel (type AD-VS8A4)
8-channel (type AD-VS8A8)
|
broad range
20..253VDC,
50..253VAC
|
VarioShow AD-VS8A4-G indicator
with galvanic isolated current input
AD-Studio configurable
|
current (max.20mA),
voltage (max.10V)
|
only 4-channel
|
broad range
20..253VDC,
50..253VAC
|
VarioShow AD-VS8A4-S indicator
with intergrated transmitter supply
AD-Studio configurable
|
current (max.20mA),
voltage (max.10V)
|
only 4-channel
|
broad range
20..253VDC,
50..253VAC
|
|
indicator & data logging
|
input
|
output
|
power supply
|
VarioLog AD-VL8 indicator
with data-logging on memory card
AD-Studio configurable
|
current (max.20mA),
voltage (max.10V)
|
1-channel (type AD-VL8A1)
4-channel (type AD-VL8A4)
8-channel (type AD-VL8A8)
|
broad range
20..253VDC,
50..253VAC
|
VarioLog AD-VL8A4-G indicator
with data-logging and galvanic
isolated current input
AD-Studio configurable
|
current (max.20mA),
voltage (max.10V)
|
only 4-channel
|
broad range
20..253VDC,
50..253VAC
|
VarioLog AD-VL8A4-S indicator
with data-logging and integrated
transmitter supply
AD-Studio configurable
|
current (max.20mA),
voltage (max.10V)
|
only 4-channel
|
broad range
20..253VDC,
50..253VAC
|
|
indicator
|
interface
|
display
|
power supply
|
AD-MM 400 monitor modul
96x96 mm
|
RS-485
(Modbus-RTU)
|
3,5" TFT (320x240 pixel)
|
broad-range
20...253VDC
|
|
indicating & operating module
|
feature
|
AD-VarioControl
|
- LCD for display of different operating modes, lit in several colours (R/Y/B)
- to configure the device parameters
- also for backup and restoration of device parameters
- removeable (hot-plugged)
|
|
Accessories für VarioShow and VarioLog devices
|
AD-Studio & VarioPass configuration software & connection adapter set
|
VarioLog SD-memory card 1GB (Item-no: ADVL8SPEICHER2)
industrial grade product with extended operating temperature range and guaranteed read and write cycles
|
|
Mounting accessories
|
DIN RAIL bracket for panel-mount-case devices (Item-no: AD-FEAUFHUT)
allows the mounting of 96x48mm switch panel mounting devices on DIN RAIL
|
Reduction-Adapter-Plate 96 (Item-no. AD-REDUZIERBL96)
Solves the veneering problem of stamped sheet metal differences in the exchange of the front chassis units of size 96x96 mm
with holes of size 96x48 mm
|
Reduction-Adapter-Plate 144 (Item-no: AD-REDUZIERBL144)
Solves the veneering problem of stamped sheet metal differences in the exchange of the front chassis units of size 144x144 mm
with holes of size 96x48 mm
|
Manufacturer :Adamczewski
Product :Indicator lights/Fault Indicator
Indicator lights/Fault Indicator
Informs about errors or operation conditions via LED signal transmitter
type
|
construction
|
LED
|
power supply
|
AD-LM 6
LED fault indicator
for 6 messages
|
72x72 mm panel mounting
|
exchangeable acc. to order data
signalling input: 10...30VDC
|
20...30VDC only for
lamp test operation
|
AD-LM 8
LED fault indicator
for 8 messages
|
96x96 mm panel mounting
|
exchangeable acc. to order data
signalling input: 10...30VDC
|
20...30VDC only for
lamp test operation
|
AD-LM 12
LED fault indicator
for 6 messages
|
72x144 mm panel mounting
|
exchangeable acc. to order data
signalling input: 10...30VDC
|
20...30VDC only for
lamp test operation
|
AD-LM 16
LED fault indicator
for 16 messages
|
96x96 mm panel mounting
|
exchangeable acc. to order data
signalling input: 10...30VDC
|
20...30VDC only for
lamp test operation
|
Manufacturer :Adamczewski
Product :Power-Meter, Voltage-, Phase, Load-Monitoring
Measures all values of a one- and three-phase system (active-, reactive-, apparent-power, voltage, currents, harmonics, phase angle, power factor etc.)
Power Measurement
active-power, reactive-power, cos.-phi.
multifunctional
programmable
|
input
|
output / interface
|
power supply
|
AD-LU 10 GT (3-phase)
power meter analog output
AD-Studio configurable
|
1x max. 20A/253VAC via front
mounted push-through current
transformer
|
1x analog (max. 20mA)
1x opto couplers
|
via measuring
input L1
|
AD-LU 20 GT (3-phase)
power meter with
ethernet-interface
|
3x max. 20A/253VAC via front
mounted push-through current
transformer
|
1x Ethernet (modbus-TCP)
1x RS485 (modbus-RTU)
|
via measuring
input L1
|
AD-LU 25 GT (3-phase)
power meter with
ethernet-interface
|
3x max. 600A/253VAC via external
push-through current transformer
|
1x Ethernet (modbus-TCP)
1x RS485 (modbus-RTU)
|
via measuring
input L1
|
AD-LU 30 GT (3-phase)
power meter with
BUS-interface
AD-Studio configurable
|
3x max. 20A/253VAC via front
mounted push-through current
transformer
|
RS485 (modbus-RTU)
|
via measuring
input L1
|
AD-LU 35 GT (3-phase)
power meter with
BUS-interface
AD-Studio configurable
|
3x max. 600A/253VAC via external
push-through current transformer
|
RS485 (modbus-RTU)
|
via measuring
input L1
|
AD-LU 40 GT-PB
AD-LU 40 GT-PN
3-phase power meter
with BUS-interface
AD-Studio configurable
|
3x max. 20A/253VAC via front
mounted push-through current
transformer
|
-PB incl. PROFIBUS
-PN incl. PROFINET
-RS485 (modbus-RTU)
|
via measuring
input L1
|
AD-LU 45 GT-PB
AD-LU 45 GT-PN
3-phase power meter
with BUS-interface
AD-Studio configurable
|
3x max. 600A/253VAC via external
push-through current transformer
|
-PB incl. PROFIBUS
-PN incl. PROFINET
-RS485 (modbus-RTU)
|
via measuring
input L1
|
AD-LU 50 GT (3-phase)
power meter analog output
AD-Studio configurable
|
3x max. 20A/253VAC via front
mounted push-through current
transformer
|
2x analog (max.20mA/10V)
|
via measuring
input L1
|
AD-LU 55 GT (3-phase)
power meter analog output
AD-Studio configurable
|
3x max. 600A/253VAC via external
push-through current transformer
|
2x analog (max.20mA/10V)
|
via measuring
input L1
|
AD-LU 60 FE (3-phase)
power meter front mounting
AD-Studio configurable
ordering options:
AD-LU 60 FE-B
AD-LU 60 FE-D
AD-LU 60 FE-BD
|
3x max. 20A/253VAC via push-through
transformer mounted on the rear
|
pure indicating device
|
via measuring
input L1
|
incl. BUS interface RS485 (modbus RTU)
incl. 2 digital output (open collector)
incl. BUS interface RS485 (modbus RTU) and digital output 2x open collector
|
AD-LU 70 FE-PB
AD-LU 70 FE-PN
power meter front mounting
with BUS-interface
AD-Studio configurable
|
3x max. 20A/253VAC via push-through
transformer mounted on the rear
|
-PB incl. PROFIBUS
-PN incl. PROFINET
-2 digital outputs (open-collector)
|
via measuring
input L1
|
AD-LU 320 GVD (1-phase)
power meter
VarioControl/-Connect compatible
AD-Studio configurable
|
1x 1/5A (253VAC)
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 325 GVD (1-phase)
power meter
VarioControl/-Connect compatible
AD-Studio configurable
|
1x max. 600A/253VAC via external
push-through current transformer
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 620 GVF (3-phase)
power meter
VarioControl/-Connect compatible
AD-Studio configurable
|
3x 1/5A (253VAC)
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
Output 3: contact (N/O)
Output 4: semiconductor
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 625 GVF (3-phase)
power meter
VarioControl/-Connect compatible
AD-Studio configurable
|
3x max. 600A/253VAC via external
push-through current transformer
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
Output 3: contact (N/O)
Output 4: semiconductor
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 610 GT (3-phase)
power meter
AD-Studio configurable
|
3x max. 20A/253VAC via front
mounted push-through current
transformer
|
2x analog (max.20mA/10V)
1x contact (max.250VAC/2A)
optional opto couplers
1x RS485 (modbus-RTU)
|
via measuring
input L1
|
AD-LU 650 GA (3-phase)
power meter
AD-Studio configurable
|
3x 1/5A (300VAC)
|
4x analog (max.20mA/10V)
2x contact (max.250VAC/2A)
optional opto couplers
1x RS485 (modbus-RTU)
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 680 GA (3-phase)
power meter
AD-Studio configurable
|
3x max. 600A/300VAC via external
push-through current transformer
|
4x analog (max.20mA/10V)
2x contact (max.250VAC/2A)
optional opto couplers
1x RS485 (modbus-RTU)
|
broad-range
20...253VDC,
50...253VAC
|
|
ACCESORIES
|
indicator
|
interface
|
display
|
power supply
|
AD-MM 400 monitor modul
96x96 mm
|
RS-485 (modbus-RTU)
|
3,5" TFT (320x240 pixel)
|
broad-range
20...253VDC
|
|
incl. factory pre-set
according to customer data
|
input
|
output
|
power supply
|
AD-LU 110 GA (1-phase)
active-power-converter
|
1x 1/5A (253VAC)
|
0...20mA, 4...20mA, 0...10V
also bipolar
|
broad-range
20...253VDC,
50...253VAC
|
AD-LU 410 GA (3-phase)
active-power-converter
|
3x 1/5A (400VAC)
|
0...20mA, 4...20mA, 0...10V
also bipolar
|
broad-range
20...253VDC,
50...253VAC
|
|
Voltage-, Phase, Load-Montoring
|
input
|
output
|
power-supply
|
AD-UW 60 GT
3-phase voltage monitor
|
80...253VAC
|
1x changeover contact
|
via input
|
AD-LW 110 GS
load-monotoring for
low-voltage and cos(phi)
|
L1/L2/L3 to N
1x max 5AAC (L1)
3x 230VAC
|
1x NO contact for low-voltage
1x NO contact for cos(phi)
|
broad-range
20...253VDC,
50...253VAC
|
Manufacturer :Adamczewski
Product :Device Communication
Tools for device communication and configuration
Device communication and configuration
Tools for device communication and -configuration
Type
|
Device Configuration
|
Configuration software
AD-Studio
|
The AD-Studio enables a configuration of all parameter via PC.
The parameter can be read, written, printed and saved.
Note: the USB adapter set AD-VarioPass is necessary as interface from device to PC!
|
USB Adapter Set
for photovoltaic devices
AD-VarioPass3
|
consisting of:
AD-VarioPass3 USB-adapter, AD-UART+ ribbon cabel, AD-UART link cabel, USB-cabel,
RS485 plug-in terminal [S], CD-ROM configuration software AD-Studio
|
Display and operating
AD-VarioControl
|
- for displaying measured values with integrated illuminated LCD display
- for configuration of the device parameters
- backup and restore of device parameters
- attachable or removable even during operation (hot-plugged)
|
|
Type
|
Device Communication
|
RS485-Interface
AD-VarioConnect
|
- for displaying measured values with integrated illuminated LCD display
- for configuration of the device parameters
- backup and restore of device parameters
- attachable or removable even during operation (hot-plugged)
- with integraded RS485-inferface (Modbus-RTU)
|
Interface Converter
AD-NetGw100GT
|
Interfaces: LAN (10/100 Mbit), RS-485, AD-UART
Protocol conversion: modbus TCP/RTU
Power-supply: broad range 20...253VDC / 50...253VAC (50...60Hz)
AD-Studio configurable
|
Mounting Accessories
|
Interface Adapter Cable
AD-NetGw-connect
|
AD-UART+ ribbon as interface-adapter-cable (6-pole/1m)
for a connection between Adamczewski devices (AD-UART interface) and interface converter AD-NetGw100GT
|
Manufacturer :Adamczewski
Product :Fieldbus Devices
for analog-, temperature-signal inputs and contacts provided and controlled via an RS485 (ModbusRTU) interface.
Fieldbus Devices
with analog-, temperature-signal inputs and bus interface
Bus Converter
|
input / interface
|
output / interface
|
power supply
|
AD-AEB 20 GX
Analog Input-Bus-Converter
AD-Studio configurable
|
2x analog signals
0...20mA, 0...10V, 0...30V
|
RS485 (modbus-RTU)
connector compatible
|
18..30VDC
connector compatible
|
AD-AEB 40 GT
Analog Input-Bus-Converter
AD-Studio configurable
|
4x analog signals
0...20mA, 0...10V
|
RS485 (modbus-RTU)
|
20...253VDC,
50...253VAC
broad range
|
AD-AAB 20 GX
Analog Output-Bus-Converter
AD-Studio configurable
|
RS485 (modbus-RTU)
connector compatible
|
2x analog signals
0...20mA, 0...10V
|
18..30VDC
connector compatible
|
AD-KEB 20 GX
Digital Input-Bus-Converter
AD-Studio configurable
|
2x digital signals
contact or active 24V
|
RS485 (modbus-RTU)
connector compatible
|
18..30VDC
connector compatible
|
AD-KAB 10 GX
Relay Output-Bus-Converter
AD-Studio configurable
|
RS485 (modbus-RTU)
connector compatible
|
1x potential-free
change-over contact
|
18..30VDC
connector compatible
|
AD-KAB 40 GT
Relay Output-Bus-Converter
AD-Studio configurable
|
RS485 (modbus-RTU)
|
4x potential-free
NO contacts
|
20...253VDC,
50...253VAC
broad range
|
AD-KAB 80 GT
Relay Output-Bus-Converter
AD-Studio configurable
|
RS485 (modbus-RTU)
|
8x potential-free
NO contacts
|
20...253VDC,
50...253VAC
broad range
|
AD-MV 55 GX
Temperature Input-Bus-Converter
AD-Studio configurable
|
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- 144 mV
|
RS485 (modbus-RTU)
connector compatible
|
18..30VDC
connector compatible
|
AD-MV 554 GT
Temperature Input-Bus-Converter
AD-Studio configurable
|
- RTD: Pt, Ni
- TC: J,T,K,E,N,S,R,B,C
- 144 mV
|
RS485 (modbus-RTU)
|
20...253VDC,
50...253VAC
broad range
|
|
indicator
|
interface
|
display
|
power supply
|
AD-MM 400 monitor modul
96x96 mm
|
RS-485
(Modbus-RTU)
|
3,5" TFT (320x240 pixel)
|
broad-range
20...253VDC
|
|
ACCESORIES
|
Interface Converter
|
Function
|
AD-NetGw100GT
Modbus RTU/TCP Converter
AD-Studio configurable
|
Network interface converter allows connection to Adamczewski
Fieldbus devices over IP-based networks LAN (10/100 Mbit)
Protocol conversion: Etherne (modbus-TCP) <=> RS485 (modbus-RTU)
|
Manufacturer :Adamczewski
Product :Frequency Converter
Frequency Converter
analogue/digital resp. digital/analogue transformation
type
|
input
|
output
|
power supply
|
AD-AI 200 GVC
Analogue-Pulse-Converter
AD-Studio configurable
|
0...20mA, 4...20mA,
0...10V
|
quantity impulses via
relay or opto couplers
e.g. 0...120Imp/m³
|
broad range
20..253VDC,
50..253VAC
|
AD-FM 255 GVD
VarioControl/-Connect and
AD-Studio configurable
|
0...0,01Hz to 0...10kHz
NAMUR, contact, open-
collector, 24V-activ i.a
|
Output 1: current (max.20mA)
Output 2: voltage (max.10V)
Output 3: contact (changeover contact)
(optional semiconductor)
|
broad range
20...253VDC,
50...253VAC>
|
AD-FM 250 GVC
Analogue-Frequency-Converter
AD-Studio configurable
|
0...0,01Hz to 0...10 kHz
NAMUR, contact, open-
collector, 24V-activ i.a
|
current (max.20mA)
voltage (max.10V)
|
broad range
20..253VDC,
50..253VAC
|
AD-FM 210 GS
Analogue-Frequency-Converter
|
0...100Hz to 50kHz
NAMUR, contact, open-
collector, 24V-activ i.a
|
0...20mA, 4...20mA, 0...10V
to specify by order
|
broad range
20..253VDC,
50..253VAC
|
AD-FM 300 FE (1-channel)
AD-FM 600 GA (1-channel)
Frequency-Converter
AD-Studio configurable
|
0...0,01Hz to 0...10kHz
NAMUR, contact, open-
collector, 24V-activ i.a
|
analog (each channel):
1x current (max.20mA)
1x voltage (max.10V)
digital (each channel):
2x relay (changeover)
optional opto couplers
|
broad range
20..253VDC,
50..253VAC
|
AD-FM 600 FE (2-channel)
AD-FM 600 GA (2-channel)
Frequency-Converter
AD-Studio configurable
|
0...0,01Hz to 0...10kHz
NAMUR, contact, open-
collector, 24V-activ i.a
|
analog (each channel):
1x current (max.20mA)
1x voltage (max.10V)
digital (each channel):
2x relay (changeover)
optional opto couplers
|
broad range
20..253VDC,
50..253VAC
|
Manufacturer :Adamczewski
Product :Impulse Converter
Impulse Converter
add, divide, contact protection
impulse converter
|
input
|
output
|
power supply
|
AD-IS 102 GVC (2 inputs)
Pulse Summator
AD-Studio configurable
|
2x
pulse inputs
|
changeover contact
optional opto couplers
|
broad range
20..253VDC,
50..253VAC
|
AD-IS 106 GVF (6 inputs)
Pulse Summator
AD-Studio configurable
|
6x
pulse inputs
|
changeover contact
optional opto couplers
|
broad range
20..253VDC,
50..253VAC
|
AD-IU 214 GVC
Pulse-Divider
AD-Studio configurable
|
1x
pulse input
|
changeover contact
optional opto couplers
2:1 to 9999:1
|
broad range
20..253VDC,
50..253VAC
|
|
impulse converter
|
input
|
output
|
power supply
|
AD-AI 200 GVC
Analogue-Pulse-Converter
AD-Studio configurable
|
0...20mA,
4...20mA,
0...10V
|
quantity impulses via
relay or opto couplers
e.g. 0...120 Imp/m³
|
broad range
20..253VDC,
50..253VAC
|
|
contact protection
|
input
|
output
|
power supply
|
AD-KI 10 GX
Contact-Protection-Relay
|
pulse input
|
1x normally-open contact
|
18...30VDC
|
AD-KI 100 GS
Contact-Protection-Relay
|
pulse input
|
2x changeover contact
|
broad range
20..253VDC,
50..253VAC
|
AD-KI 100 GSo opto couplers
Contact-Protection
|
pulse input
|
2x opto couplers
|
broad range
20..253VDC,
50..253VAC
|
AD-KV 100 GS
Contact-Amplifier
|
pulse input
|
2x changeover contact
output/input = 1:1
|
broad range
20..253VDC,
50..253VAC
|
AD-KV 100 GSo opto couplers
Contact-Amplifier
|
pulse input
|
2x opto couplers
output/input = 1:1
|
broad range
20..253VDC,
50..253VAC
|
|
coupling relay
|
input
|
output
|
power supply
|
AD-KR 11 GX
Coupling Relay (1-channel)
|
20...30VDC
|
1 changeover contact
|
18...30VDC also
via DIN rail connector
|
AD-KR 12 GX
Coupling Relay (1-channel)
|
20...30VDC
|
2 normally-open contact
|
18...30VDC also
via DIN rail connector
|
AD-KR 22 GX
Coupling Relay (2-channel)
|
20...30VDC
|
1 normally-open contact
per channel
|
18...30VDC also
via DIN rail connector
|
Manufacturer :Adamczewski
Product :Overvoltage Protection, Surge Protection
Surge Protection
type
|
input
|
output
|
power supply
|
AD-BS 1
high-voltage-protection
|
90V
|
for 2 lines
|
|
AD-BS 2
combined high-voltage protector
and fine-protection module
|
24V, 33V, 50V
others on request
|
for 2 lines
|
|
AD-BS 3
combined high-voltage protector
and fine-protection module
|
24V, 33V, 50V
others on request
|
for 2 lines
|
transverse- voltage-limiting
|
AD-NS 230
mains protection
|
230VAC
|
for 2 lines
|
breakdown indication
|
AD-ÜSE 2/2-xx
combined high-voltage protector and
fine-protection module for outdoor installation
|
24V, 33V, 50V
others on request
|
for 2 lines
|
|
AD-ÜSE 2/3-xx
combined high-voltage protector and
fine-protection module for outdoor installation
|
24V, 33V, 50V
others on request
|
for 3 lines
|
|
AD-ÜSE 2/4-xx
combined high-voltage protector and fine-
protection module for outdoor installation
|
24V, 33V, 50V
others on request
|
for 4 lines
|
|
AD-ÜSE 3/2-xx
combined high-voltage protector and fine-
protection module for outdoor installation
|
24V, 33V, 50V
others on request
|
for 2 lines
|
transverse- voltage-limiting
|
AD-ÜSE 3/3-xx
combined high-voltage protector and fine-
protection module for outdoor installation
|
24V, 33V, 50V
others on request
|
for 3 lines
|
transverse- voltage-limiting
|
AD-ÜSE 3/4-xx
combined high-voltage protector and fine-
protection module for outdoor installation
|
24V, 33V, 50V
others on request
|
for 4 lines
|
transverse- voltage-limiting
|
Manufacturer :Adamczewski
Product :Contact Protection Relays and Coupling Relays
Contact-Protection-Relays and Coupling Relay
contact protection
|
input
|
output
|
power supply
|
AD-KI 10 GX
Contact-Protection-Relay
|
1 normally-open contact
(NAMUR, contact, 24V)
|
1x normally-open contact
|
18...30VDC
|
AD-KI 100 GS
Contact-Protection-Relay
|
1x normally-open contact
|
2x changeover contact
|
broad range
20..253VDC, 50..253VAC
|
AD-KI 100 GSo open-collector
Contact-Protection
|
1x normally-open contact
|
2x open-collector
|
broad range
20..253VDC, 50..253VAC
|
AD-KV 100 GS
Contact-Amplifier
|
1x normally-open contact
|
2x changeover contact
output/input = 1:1
|
broad range
20..253VDC, 50..253VAC
|
AD-KV 100 GS
Contact-Amplifier
|
1x normally-open contact
|
2x open-collector
output/input = 1:1
|
broad range
20..253VDC, 50..253VAC
|
|
coupling relay
|
input
|
output
|
power supply
|
AD-KR 11 GX
Coupling Relay (1-channel)
|
20...30VDC
|
1 changeover contact
|
18...30VDC
|
AD-KR 12 GX
Coupling Relay (1-channel)
|
20...30VDC
|
2 normally open contact
|
18...30VDC
|
AD-KR 22 GX
Coupling Relay (2-channel)
|
20...30VDC
|
1 normally open contact per channel
|
18...30VDC
|
Manufacturer :Adamczewski
Product :Special Functions
Special Function
compute, multiplier, memorise , regularise, nominal-values
type
|
input
|
output
|
power supply
|
AD-SWG 211 GS
Nominal-Value-Generator 0...99%
|
-
|
0...20mA, 4...20mA, 0...10V
|
230VAC or
20...30VDC
|
AD-TV 32 GL
Vario-Isolation Amplifier
all standard-signals selectable
and with nominal value selector
|
0...20mA, 4...20mA, 0...10V
|
0...20mA, 4...20mA, 0...10V
and nominal value selector
|
broad range
20..253VDC,
50..253VAC
|
AD-TV 320 GS
Setpoint-Isolation-Amplifier with
remote activation, call back contact
and transmitter supply
|
0...20mA, 4...20mA, 0...10V
with optional transmitter
supply of 4-20mA
|
0...20mA, 4...20mA, 0...10V
(1:1 to input or as setpoint)
|
broad-range
20...253VDC,
50...253VAC
|
AD-SMV 400 GVC
Sum-Data-Amplifier
AD-Studio configurable
|
max. 20mA/10V
4 inputs (freely configurable)
|
0...20mA, 4...20mA, 0...10V
(freely configurable)
|
broad-range
20...253VDC,
50...253VAC
|
AD-MU 400 GVC
Analogue Calculator
AD-Studio configurable
|
max. 20mA/10V
2 inputs (freely configurable)
|
0...20mA, 4...20mA, 0...10V
(freely configurable)
|
broad-range
20...253VDC,
50...253VAC
|
AD-AS 320 GS
Analogue Memory
|
0...20mA, 4...20mA; 0...10V
|
0...20mA, 4...20mA, 0...10V
|
broad-range
20...253VDC,
50...253VAC
|
AD-RA 300 GVF
Redundancy Evaluator
AD-Studio configurable
|
3x max. 20mA
|
max. 20mA, 10V
3 changeover contact
(as fault indication)
|
broad-range
20...253VDC,
50...253VAC
|
AD-ER 01 GS
Electrode Relays
|
3 electrodes
|
1 changeover contact
|
broad-range
20...253VDC,
50...253VAC
|
AD-ISW 100 GS
Incremental Nominal
Value Generator
|
potential-free contact
or DC-voltage 5...30V
|
0...20mA, 4...20mA, 0...10V
by user request
|
broad-range
20...253VDC,
50...253VAC
|
AD-MMA 400 GVC
Maximum-/Minimum Value Evaluator
AD-Studio configurable
|
up to 4 input
current max. 20mA
voltage max. 10V
|
max. or min. input value 1:1
|
broad-range
20...253VDC,
50...253VAC
|
AD-BV 20 GVC
Burden Amplifier
|
0...20mA, 4...20mA; 0...10V
|
1:1 input/output
(output burden 1,3kOhm)
|
broad-range
20...253VDC,
50...253VAC
|
AD-SV 20 GS
Voltage Supply
|
-
|
24VDC, max. 50mA
|
broad-range
20...253VDC,
50...253VAC
|
AD-SV 40 GS (2 channel)
Voltage Supply
|
-
|
2x 24VDC, max. 50mA
|
broad-range
20...253VDC,
50...253VAC
|
AD-SV 1224 GL
Power Converter
|
-
|
20...30VDC
|
11...15VDC
|
Manufacturer :Adamczewski
Product :Photovoltaics
For optimising, distribution and monitoring the self-generated energy at photovoltaic units
Photovoltaics
For optimising, distribution and monitoring the self-generated energy at photovoltaic units
Photovoltaic-Optimizer
|
type
|
input
|
output
|
AD-PVO 2000
VarioPass 3 configurable
|
3x 230VAC
3x 0...100AAC via
external push-through current tansformer
(incl. in the set)
|
Load-relay: 1 normally open
Error-relay: 1 change-over contact
|
AD-PVO 3000
VarioPass 3 configurable
|
3x 230VAC
3x 0...100AAC via
external push-through current tansformer
(incl. in the set)
|
Anlog output: 0/4...20mA; 0/2...10V
Error-relay: 1 change-over contact
(att. to region regulations)
|
AD-PVO 4000
VarioPass 3 configurable
|
3x 230VAC
3x 0...100AAC via
external push-through current tansformer
(incl. in the set)
|
Ethernet interface for connection of the
heating element AC ELWA-E (my-PV GmbH)
integrated web server
|
AD-PVO 6000
VarioPass 3 configurable
|
3x 230VAC
3x 0...100AAC via
external push-through current tansformerr
(incl. in the set)
|
Load-relay: 3 normally open
Error-relay: 1 change-over contact
|
Description:
The Photovoltaic-Optimizer AD-PVO 2000 and AD-PVO 6000 monitors the supply of solar energy to the main connection of a building. If the supply
output exceeds a limiting value set by the customer via a PC, one or several internal output relay is triggered. With this switching relays, electric
consumers (i.e. electric heating rod in the process water tank of the heating, air-conditioning device or heat pump) can now be triggered. The
device is compatible with most heat pumps with SG-Ready logo. The AD-PVO 3000 has an analog output, which can be controlled by the most
common thyristor switches. Thus resistive loads (eg electric heaters) can be adjusted continuously. In addition, all variables of the three-phase
network (voltage, current, power, etc.) can be displayed and looged via AD-Studio. With the AD-PVO 2000, 3000 or 6000, the energy is converted
on site and not fed back into the public low-voltage network.
Note:
For the operation of the AD PVO 3000 with a thyristor switch, please pay attention to region- and country-specific regulations (technical
connection requirements).
|
Photovoltaic-Optimizer-Set
|
type
|
description
|
AD-PVO 2000S
- photovoltaic-optimizer
- screw-in heater
|
Photovoltaic-Optimizer-Heater-Set
for direct use in the hot water tank, consisting of:
1 pcs. AD-PVO 2000 photovoltaic-optimizer
1 pcs. AD-HST screw-in heater (1,5" with temperature regulator and safety thermostat)
|
AD-PVO 2000S-DLE
- photovoltaic-optimizer
- continuous-flow heater
|
Photovoltaic-Optimizer-Continuous-Flow-Heater-Set
with storage water charging system. For hot-water tanks without capability of connecting additional heater.
Set consists of:
1 pcs. AD-PVO 2000 photovoltaic-optimizer
1 pcs. AD-DLE coninuous-flow heater (consisting of: continous-flow heater, insulated box, circulation pump
and thermostat distribution beam)
|
AD-PVO 6000S
- photovoltaic-optimizer
- screw-in heater
|
Photovoltaic-Optimizer-Heater-Set
for direct use in the hot water tank, consisting of:
1 pcs. AD-PVO 6000 photovoltaic-optimizer
1 pcs. AD-HST screw-in heater (1,5" with temperature regulator and safety thermostat)
|
AD-PVO 6000S-DLE
- photovoltaic-optimizer
- continuous-flow heater
|
Photovoltaic-Optimizer-Continuous-Flow-Heater-Set
with storage water charging system. For hot-water tanks without capability of connecting additional heater.
Set consists of:
1 pcs. AD-PVO 6000 photovoltaic-optimizer
1 pcs. AD-DLE coninuous-flow heater (consisting of: continous-flow heater, insulated box, circulation pump
and thermostat distribution beam)
|
Accessory
|
type
|
description
|
AD-HST35
screw-in heater
|
screw-in heater with temperature regulator and safety thermostat,
mounting length: 480mm, unheated zone: 100mm, fitting: 1½"; (DIN ISO 228)
power zone 1: 500W, zone 2: 1.000W and zone 3: 2.000W
|
AD-DLE
continuous-flow heater
|
continuous-flow heater set
consisting of: continous-flow heater, insulated box, circulation pump and thermostat distribution beam
|
VarioPass 3
configuration set
|
USB-configuration-set
consisting of: AD-VarioPass 3 USB-adapter, AD-UART+ rippon cable (8cm), USB-cablel (1,5m A/B)
and configuration software AD-Studio
|
Versions
Adamczewski
GVB - switchboard housing
for snapping onto DIN rail
13 x 110 x 134mm (wxhxd)
|
|
Adamczewski
GT - switchboard housing
for snapping onto DIN rail
width x height x depth
71 x 90 x 58mm (wxhxd)
|
|
|
|
Adamczewski
GVC - switchboard housing
for snapping onto DIN rail
18 x 110 x 134mm (wxhxd)
|
|
Adamczewski
ST - plug-in-module
for snapping onto DIN rail
20,8 x 42,5 x 102mm (wxhxd)
|
|
|
|
Adamczewski
GVD - switchboard housing
for snapping onto DIN rail
23 x 110 x 134mm (wxhxd)
|
|
Adamczewski
FE - Panel-mount-case
for switchboard front
mounting
96 x 48 x 136mm (wxhxd)
|
|
|
|
Adamczewski
GVF - switchboard housing
for snapping onto DIN rail
33 x 110 x 134mm (wxhxd)
|
|
Adamczewski
surface housing IP-95 (ÜSE)
built on housing, PG16-glands
125 x 80 x 57mm (wxhxd)
|
|
|
|
Adamczewski
GX - switchboard housing
for snapping onto DIN rail
6,2 x 92 x 101mm (wxhxd)
|
|
Adamczewski
surface housing IP-95 (ÜSK)
built on housing, PG16-glands
175 x 80 x 57mm (wxhxd)
|
|
|
|
Adamczewski
GM - switchboard housing
for snapping onto DIN rail
18 x 78 x 98mm (wxhxd)
|
|
Adamczewski
GB - surface housing
DIN rail series installation
or built on housing
63 x 100 x 95mm (wxhxd)
|
|
|
|
Adamczewski
GL - switchboard housing
for snapping onto DIN rail
13 x 78 x 98mm (wxhxd)
|
|
Adamczewski
MO - module
for soldering in and retrofitting
printing circuit boards
30 x 20 x 16,5mm (wxdxh)
|
|
|
|
GS - switchboard housing
for snapping onto DIN rail
23 x 78 x 98mm (wxhxd)
|
|
Adamczewski
GA - surface housing
for snapping onto DIN rail
100 x 74 x 119mm (wxhxd)
|
|
|
|
Adamczewski
GF - switchboard housing
for snapping onto DIN rail
23 x 78 x 103mm
|
|
Adamczewski
EV - 19" euro-board format
as plug-in in 19" assembly
carrier connection type "F"
Front: 3TE, 4TE, 6TE
|
Product list
Manufacturer |
Product codes
|
Adamczewski |
AD-EN-FM400GA_APPL |
Adamczewski |
AD-EN-AF100 |
Adamczewski |
AD-EN-DA3 |
Adamczewski |
AD-EN-FM200GS |
Adamczewski |
AD-EN-FM350GC |
Adamczewski |
AD-EN-IS108EV |
Adamczewski |
AD-EN-IS108GA |
Adamczewski |
AD-EN-IU114 |
Adamczewski |
AD-EN-IU114GA |
Adamczewski |
AD-EN-KI100EV |
Adamczewski |
AD-EN-KI100GB |
Adamczewski |
AD-EN-KR100 |
Adamczewski |
AD-EN-LU310GVC |
Adamczewski |
AD-EN-LU410 (V01_2010) |
Adamczewski |
AD-EN-LU610GA |
Adamczewski |
AD-EN-LU610GT |
Adamczewski |
AD-EN-LU610GVF |
Adamczewski |
AD-EN-LW100 |
Adamczewski |
AD-EN-MA310 |
Adamczewski |
AD-EN-MI310 |
Adamczewski |
AD-EN-MK101 |
Adamczewski |
AD-EN-MK201 |
Adamczewski |
AD-EN-MK401 |
Adamczewski |
AD-EN-MK530GS |
Adamczewski |
AD-EN-MU200GA |
Adamczewski |
AD-EN-MV110 |
Adamczewski |
AD-EN-MV500 |
Adamczewski |
AD-EN-MV504 |
Adamczewski |
AD-EN-MV504GS |
Adamczewski |
AD-EN-MV544GA |
Adamczewski |
AD-EN-PW100GC |
Adamczewski |
AD-EN-SAM101 |
Adamczewski |
AD-EN-SAM201 |
Adamczewski |
AD-EN-SMV310 |
Adamczewski |
AD-EN-STH22GL |
Adamczewski |
AD-EN-STV211 |
Adamczewski |
AD-EN-STV400GS |
Adamczewski |
AD-EN-SV100 |
Adamczewski |
AD-EN-TV200EV |
Adamczewski |
AD-EN-TV200GA |
Adamczewski |
AD-EN-TV350GA |
Adamczewski |
AD-EN-TV380GA |
Adamczewski |
AD-EN-TV410 |
Adamczewski |
AD-EN-TV450GA |
Adamczewski |
AD-EN-TV511GS |
Adamczewski |
AD-EN-TV513GA |
Adamczewski |
AD-EN-TV525 |
Adamczewski |
AD-EN-TV551GS |
Adamczewski |
AD-EN-TV561GC |
Adamczewski |
AD-EN-TV563GA |
Adamczewski |
AD-EN-TW2125GBST |
Adamczewski |
AD-EN-TW401 |
Adamczewski |
AD-EN-TW401MO |
Adamczewski |
AD-EN-TW401ST |
Adamczewski |
AD-EN-TW500 |
Adamczewski |
AD-EN-TW501ST |
Adamczewski |
AD-EN-TW600 |
Adamczewski |
AD-EN-TW601ST |
Adamczewski |
AD-EN-TWT2125GS |
Adamczewski |
AD-EN-USK |
Adamczewski |
AD-EN-VC2A |
Türkiyede Adamczewski ürünleri ile ilgili uygun rekabetçi fiyatları almak için müşteri temsilcimiz ile http://www.imajteknik.com.tr/bize-ulasin veya Fiyat teklifi formunu doldurarak mesaj bırakmanız halinde satış mühendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.