Asahi Enterprise

Asahi Enterprise Control system products

Asahi  Hyper Regulator 640A / 640B Series

Hyper regulator

640A / 640B series

High-precision type for positive pressure and secondary pressure control

The supply pressure (primary pressure) is reduced and the output pressure (secondary pressure) is controlled to be constant. The built-in controller compensates for output pressure drift.

There are A type with built-in sensor and B type with sensor exterior.

In addition to the pressure sensor, the B type can be connected to analog output sensors such as flow rate sensors and position sensors

 

Standard specifications

Asahi Model number

Asahi  Hyper Regulator 640AA1

Asahi  Hyper Regulator 640AB1

Asahi  Hyper Regulator 640AD1

Asahi  Hyper Regulator 640AH1

Set pressure

0 ~ 0.8 MPa

0 ~ 0.3 MPa

0 ~ 0.1 MPa

0 ~ 1 MPa

Input signal * 1

0-5V (0-10V / 4-20mA / other, please specify)

Supply pressure

Maximum output span + 0.05MPa

Power supply

24 VDC

Connection diameter

1/8 (1/4 = change the 3rd digit of the model number to 1)

Fluid used

Air (When using a flow rate other than air, select the external pilot type)

Sensor * 2

Built-in pressure sensor (A type is changed to B for pressure sensor exterior type)

Input impedance

10 kΩ or more (voltage input) / 300 Ω or less (current input)

Mounting direction

Optional (no drift will occur depending on the mounting direction)

control method

Force balance + APID control

Flow rate consumed

1.5LPM or less (standard type) to 5LPM or less (high speed type)

weight

0.8 kg

Insulation resistance

1 MΩ or more

Hysteresis

± 0.05% or less

Linearity

± 0.3% or less (depending on the sensor used together)

Orifice diameter

4 mmΦ

response speed

0.05sec or less (Characteristic without load)

Material

Body = ADC12 / Internal parts = A2017, SUS304
diaphragm = NBR or Viton / Seal = Viton

NOTE

* 1 - Change the last digit of the model number.
(1 = 0-5V / 2 = 0-10V / 3 = 4-20mA / 5 = Other, please specify)

* 2 - By selecting B type, you can bypass the piping resistance and achieve high-speed response. When using an analog sensor other than the pressure sensor, specify the sensor output.

If compound pressure is required, please refer to 640AC, 640BC

* Please contact us for detailed dimensions and characteristic data.

option

  • CCLINK compatible: Contact us for details.

  • External pilot specification: Use when using a gas other than air.

  • Special diaphragm: Viton and Teflon are available.

  • Special seals: Viton, Teflon and polyurethane are available.

* Please contact us for details of optional specifications.

 

Asahi  Hyper Regulator 640AC, 640BC Series

Hyper regulator

640AC, 640BC series

High precision type for vacuum coupled secondary pressure control

The supply pressure (primary pressure) is reduced and the output pressure (secondary pressure) is controlled to be constant. The built-in controller compensates for output pressure drift.

There are A type with built-in sensor and B type with sensor exterior.

In addition to the pressure sensor, the B type can be connected to analog output sensors such as flow rate sensors and position sensors.

The vacuum type is a 2-way valve. If you need an exhaust port, please use continuous molding.

 

Standard specifications

Asahi Model number

Asahi  Hyper Regulator  640AC1

Asahi  Hyper Regulator  640BC

Set pressure

-0.1 ~ 0.3 MPa

-0.1 ~ 0.3 MPa

Input signal * 1

0-5V (0-10V / 4-20mA / other, please specify)

Supply pressure

Maximum output span + 0.05MPa

Power supply

24 VDC

Connection diameter

1/8 (1/4 = change the 3rd digit of the model number to 1)

Fluid used

Air (External pilot type is required for vacuum)

Sensor * 2

Pressure sensor built-in type (A type is changed to B for pressure sensor exterior type)

Input impedance

10 kΩ or more (voltage input) / 300 Ω or less (current input)

Mounting direction

Arbitrary (Drift of ± 1% or less occurs depending on the mounting direction)

control method

Force balance + APID control

Flow rate consumed

1.5LPM or less (standard type) to 5LPM or less (high speed type)

weight

0.8kg (continuous molding = 1.4kg)

Insulation resistance

1 MΩ or more

Hysteresis

± 0.1% or less

Linearity

± 0.3% or less (depending on the sensor used together)

Orifice diameter

4 mmΦ

response speed

0.05sec or less (Characteristic without load)

Material

Body = ADC12 / Diaphragm = NBR / Seal = NBR

NOTE

* 1  - Change the last digit of the model number.
(1 = 0-5V / 2 = 0-10V / 3 = 4-20mA / 5 = Other, please specify)

* 2 -  By selecting B type, you can bypass the piping resistance and achieve high-speed response. When using an analog sensor other than the pressure sensor, specify the sensor output.

* Please contact us for detailed dimensions and characteristic data.


Option

Special diaphragm: Viton and Teflon are available.

Special seals: Viton, Teflon, and polyurethane are available.

Vacuum pilot specification: No external pilot is used.

* Please contact us for details of optional specifications.

 

Asahi  Hyper regulator 752A, 752B series

Hyper regulator

752A, 752B series

High-precision type for positive pressure and secondary pressure control

The supply pressure (primary pressure) is reduced and the output pressure (secondary pressure) is controlled to be constant. The built-in controller fully compensates for output pressure drift.

There are A type with built-in sensor and B type with sensor exterior.

In addition to pressure sensor, B type can be connected with analog output sensors such as flow rate sensor and position sensor.

Standard specifications

Asahi Model number

Asahi  Hyper regulator 752AA1

Asahi  Hyper regulator 752AB1

Asahi  Hyper regulator 752AD1

Asahi  Hyper regulator 752AH1

Set pressure

0 ~ 1 MPa

0 ~ 0.3 MPa

0 ~ 0.1 MPa

0 ~ 2 (2.5) MPa

Input signal * 1

0-5V (0-10V / 4-20mA / other, please specify)

Supply pressure

Maximum output + 0.1MPa

Power supply

24 VDC

Connection diameter

3/8

Fluid used

Air (When using a flow rate other than air, select the external pilot type)

Sensor * 2

Pressure sensor built-in type (A type is changed to B for pressure sensor exterior type)

Input impedance

10 kΩ or more (voltage input) / 300 Ω or less (current input)

Mounting direction

Arbitrary (Drift of ± 1% or less occurs depending on the mounting direction)

control method

Force balance + APID control

Flow rate consumed

1.5LPM or less (low consumption flow type) to 5LPM or less (standard type)

weight

1.8 kg

Insulation resistance

1 MΩ or more

Hysteresis

± 0.1% or less

Linearity

± 0.5% or less (depending on the sensor used together)

Orifice diameter

11 mmΦ

response speed

0.05sec or less (Characteristic under no load)

Material

Body = A2017 (ADC12)
Diaphragm = Viton, NBR / Seal = Viton

NOTE

* 1  Change the last digit of the model number.
(1 = 0-5V / 2 = 0-10V / 3 = 4-20mA / 5 = Other, please specify)

* 2  By selecting B type, the piping resistance can be bypassed and high-speed response can be achieved. When using an analog sensor other than the pressure sensor, specify the sensor output.

Please refer to 752AC and 752BC when compound pressure is required.

* Please contact us for detailed dimensions and characteristic data.

option

  • CCLINK compatible: Contact us for details.

  • External pilot specification: Use when using a gas other than air.

  • Special diaphragm: Viton and Teflon are available.

  • Special seals: Viton, Teflon and polyurethane are available.

  • High-speed type: Pilot booster is also used. The highest speed control is possible.

* Please contact us for details of optional specifications.

 

Asahi  Hyper regulator 752AC, 752BC series

Hyper regulator

752A, 752B series

High-precision type for positive pressure and secondary pressure control

The supply pressure (primary pressure) is reduced and the output pressure (secondary pressure) is controlled to be constant. The built-in controller fully compensates for output pressure drift.

There are A type with built-in sensor and B type with sensor exterior.

In addition to pressure sensor, B type can be connected with analog output sensors such as flow rate sensor and position sensor.

Standard specifications

Asahi Model number

Hyper regulator 752AA1

Hyper regulator  752AB1

Hyper regulator 752AD1

Hyper regulator  752AH1

Set pressure

0 ~ 1 MPa

0 ~ 0.3 MPa

0 ~ 0.1 MPa

0 ~ 2 (2.5) MPa

Input signal * 1

0-5V (0-10V / 4-20mA / other, please specify)

Supply pressure

Maximum output + 0.1MPa

Power supply

24 VDC

Connection diameter

3/8

Fluid used

Air (When using a flow rate other than air, select the external pilot type)

Sensor * 2

Pressure sensor built-in type (A type is changed to B for pressure sensor exterior type)

Input impedance

10 kΩ or more (voltage input) / 300 Ω or less (current input)

Mounting direction

Arbitrary (Drift of ± 1% or less occurs depending on the mounting direction)

control method

Force balance + APID control

Flow rate consumed

1.5LPM or less (low consumption flow type) to 5LPM or less (standard type)

weight

1.8 kg

Insulation resistance

1 MΩ or more

Hysteresis

± 0.1% or less

Linearity

± 0.5% or less (depending on the sensor used together)

Orifice diameter

11 mmΦ

response speed

0.05sec or less (Characteristic under no load)

Material

Body = A2017 (ADC12)
Diaphragm = Viton, NBR / Seal = Viton

NOTE

* 1 Change the last digit of the model number.
(1 = 0-5V / 2 = 0-10V / 3 = 4-20mA / 5 = Other, please specify)

* 2 By selecting B type, the piping resistance can be bypassed and high-speed response can be achieved. When using an analog sensor other than the pressure sensor, specify the sensor output.

Please refer to 752AC and 752BC when compound pressure is required.

* Please contact us for detailed dimensions and characteristic data.

 

option

  • CCLINK compatible: Contact us for details.

  • External pilot specification: Use when using a gas other than air.

  • Special diaphragm: Viton and Teflon are available.

  • Special seals: Viton, Teflon and polyurethane are available.

  • High-speed type: Pilot booster is also used. The highest speed control is possible.

* Please contact us for details of optional specifications.

 

Asahi  Hyper relief valve 635B series

Hyper-relief valve
635B series

High-precision type for positive pressure relief control

By adjusting the displacement of the primary pressure, the process pressure (primary pressure) is controlled to be constant. The integrated controller compensates for process pressure drift.

There is only B type of sensor exterior.

In addition to the pressure sensor, the B type can be connected to analog output sensors such as flow rate sensors and position sensors.

Standard specifications

Asahi  Model number

Asahi  Hyper relief valve 635BA1

Asahi  Hyper relief valve 635BB1

Asahi  Hyper relief valve 635BD1

Asahi  Hyper relief valve 635BH1

Set pressure

0 ~ 0.8 MPa

0 ~ 0.3 MPa

0 ~ 0.1 MPa

0 ~ 1 MPa

Input signal * 1

0-5V (0-10V / 4-20mA / other, please specify)

Supply pressure

Unnecessary

Power supply

24 VDC

Connection diameter

1/8 (1/4 = change the 3rd digit of the model number to 6)

Fluid used

Air (Relief pressure control is external pilot type)

Sensor * 2

Pressure sensor exterior type

Input impedance

10 kΩ or more (voltage input) / 300 Ω or less (current input)

Mounting direction

Optional (no drift will occur depending on the mounting direction)

control method

Force balance + APID control

Flow rate consumed

1.5LPM or less (standard type) to 5LPM or less (high speed type)

weight

0.8 kg

Insulation resistance

1 MΩ or more

Hysteresis

± 0.05% or less

Linearity

± 0.3% or less (depending on the sensor used together)

Orifice diameter

4 mmΦ

response speed

0.05sec or less (Characteristic without load)

Material

Body = ADC12 / Diaphragm = NBR / Seal = NBR

NOTE

* 1 Change the last digit of the model number.
(1 = 0-5V / 2 = 0-10V / 3 = 4-20mA / 5 = Other, please specify)

* 2 Type B can bypass the piping resistance and achieve high-speed response. When using an analog sensor other than the pressure sensor, specify the sensor output.

* A back pressure proportional to the flow rate is generated due to the internal resistance of the valve. The process pressure cannot be reduced below this back pressure. Please request if you need the data.

* Please contact us for detailed dimensions and characteristic data.

option

  • Special diaphragm: Viton and Teflon are available.

  • Special seals: Viton, Teflon, and polyurethane are available.

* Please contact us for details of optional specifications.

 

Asahi  Hyper relief valve 735B series

Hyper-relief valve

735B series

High-precision type for positive pressure relief control

By adjusting the displacement of the primary pressure, the process pressure (primary pressure) is controlled to be constant. The integrated controller compensates for process pressure drift.

There is only B type of sensor exterior.

In addition to the pressure sensor, the B type can be connected to analog output sensors such as flow rate sensors and position sensors.

Standard specifications

Asahi Model number

Asahi  Hyper relief valve 735BA1

Asahi  Hyper relief valve 735BB1

Asahi  Hyper relief valve 735BD1

Asahi  Hyper relief va lve735BH1

Set pressure

0 ~ 1 MPa

0 ~ 0.3 MPa

0 ~ 0.1 MPa

0 ~ 2 MPa

Input signal * 1

0-5V (0-10V / 4-20mA / other, please specify)

Supply pressure

Not required (external pilot pressure required)

Power supply

24 VDC

Connection diameter

3/8

Fluid used

Air (Relief pressure control is external pilot type)

Sensor * 2

Pressure sensor exterior type

Input impedance

10 kΩ or more (voltage input) / 300 Ω or less (current input)

Mounting direction

Optional (no drift will occur depending on the mounting direction)

control method

Force balance + APID control

Flow rate consumed

1.5LPM or less (standard type) to 5LPM or less (high speed type)

weight

1.8 kg

Insulation resistance

1 MΩ or more

Hysteresis

± 0.05% or less

Linearity

± 0.3% or less (depending on the sensor used together)

Orifice diameter

11 mmΦ

response speed

0.05sec or less (Characteristic without load)

Material

Body = ADC12 / Diaphragm = NBR / Seal = NBR

NOTE

* 1 Change the last digit of the model number.
(1 = 0-5V / 2 = 0-10V / 3 = 4-20mA / 5 = Other, please specify)

* 2 The N type can bypass the piping resistance and achieve high-speed response. When using an analog sensor other than the pressure sensor, specify the sensor output.

* A back pressure proportional to the flow rate is generated due to the internal resistance of the valve. The process pressure cannot be reduced below this back pressure. Please request if you need the data.

* Please contact us for detailed dimensions and characteristic data.

option

  • Special diaphragm: Viton and Teflon are available.

  • Special seals: Viton, Teflon and polyurethane are available.

* Please contact us for details of optional specifications.

 

Asahi  HL regulator 940B series

HL Regulator

940B series

High precision type

The 940B series is a 2-port relief type flow control valve. It can be used to control fluid flow rate, primary pressure, secondary pressure, etc.

The wetted part is SUS316, and only one diaphragm can move in the wetted part.

Compatible with fluids with maximum operating pressure of 1MPa and maximum operating temperature of 150 ℃ or less. It is very useful for controlling special fluids under conditions that cannot be used with hyper regulators.

The 940B series has a built-in controller. It has a rangeability of less than 1/2000.

Standard specifications

Asahi Model number

Asahi  HL regulator  942BA1

Asahi  HL regulator  943BA1

Asahi  HL regulator  944BA1

Valve function

Relief pressure control

Working pressure range

Maximum 1.0 MPa

Input signal * 1

0-5V (0-10V / 4-20mA / other, please specify)

Pilot pressure

2/3 of maximum working pressure (depending on model)

Power supply

24 VDC

Connection diameter

1/4

3/8

1/2

Fluid used

Liquid, gas (Teflon, Viton, fluid that does not attack brass)

Input impedance

1 kΩ or more (voltage input) / 300 Ω or less (current input)

Mounting direction

Arbitrary (0 point drift within ± 1% may occur depending on the mounting direction)

control method

Force balance + PI control

Flow rate consumed

1.5LPM or less (standard type) to 5LPM or less (high speed type)

weight

0.8 kg

2.1 kg

2.3 kg

Insulation resistance

1 MΩ or more

Hysteresis

± 0.2% or less

Linearity

± 1% or less

Orifice diameter

4 mmΦ

8 mmΦ

16 mmΦ

response speed

0.5sec or less (Characteristic under no load)

Material

Body = Bsbm / Diaphragm = Teflon / Seal = Viton

NOTE

* 1 Change the last digit of the model number. (Example: 942NA3 / 4 ~ 20mA input)
1 = 0 ~ 5V / 2 = 0 ~ 10V / 3 = 4 ~ 20mA / 5 = Other, please specify)

* 2 It is mainly used for liquid / gas split ratio control and mixing ratio control. It is used in a system that uses a concentration sensor, flow rate sensor, and temperature sensor together.

* 3 The standard uses a metal seal, which does not result in a completely closed state. Please contact us if you need a completely closed state.

* Please contact us for detailed dimensions and characteristic data.

option

  • Special diaphragm: Viton and fluorosilicone are available.

  • Special seals: Viton, Teflon, and polyurethane are available.

  • If the ambient temperature exceeds 70 ° C, use the pilot separation type.

* Please contact us for details of optional specifications.

 

Asahi  HL regulator 910B series

HL Regulator

910B series

Multi-function high precision type

The 910 series is a 3-port multi-function servo valve. It can be used to control fluid mixing ratio, diversion ratio, flow rate, pressure, etc.

Compatible with fluids with a maximum operating pressure of 1.5 MPa and a maximum operating temperature of 150 ° C or less. It is very effective for controlling special fluids under conditions that cannot be used with hyper regulators.

The 910B series has a built-in controller.

It has a rangeability of less than 1/2000.

Standard specifications

Asahi Model number

Asahi  HL regulator  913BA1

Asahi  HL regulator 914BA1

Asahi  HL regulator 916BA1

Valve function

Opening ratio control

Working pressure range

Maximum 1.5MPa

Input signal * 1

0-5V (0-10V / 4-20mA / other, please specify)

Pilot pressure

0.3 MPa

Power supply

24 VDC

Connection diameter

1/4

3/8

1/2

Fluid used

Liquid, gas (Teflon, Viton, fluid that does not attack brass)

Input impedance

1 kΩ or more (voltage input) / 300 Ω or less (current input)

Mounting direction

Arbitrary (0 point drift within ± 1% will occur depending on the mounting direction)

control method

Force balance + PI control

Flow rate consumed

1.5LPM or less (standard type) to 5LPM or less (high speed type)

weight

2.2 kg

3.4 kg

6.8kg

Insulation resistance

1 MΩ or more

Hysteresis

± 0.2% or less

Linearity

± 1% or less

Orifice diameter

6 mmΦ

10 mmΦ

14 mmΦ

response speed

0.5sec or less (Characteristic under no load)

Material

Body = Bsbm / Diaphragm = Teflon / Seal = Viton

NOTE

* 1  -Change the last digit of the model number. (Example: 904NA3 / 4 ~ 20mA)
1 = 0 ~ 5V / 2 = 0 ~ 10V / 3 = 4 ~ 20mA / 5 = Other, please specify)

* 2 - It is mainly used for liquid / gas split ratio control and mixing ratio control. It is used in a system that uses a concentration sensor, flow rate sensor, and temperature sensor together.

 * 3 -The standard uses a metal seal, which does not result in a completely closed state. Please contact us if you need a completely closed state.

* Please contact us for detailed dimensions and characteristic data.

option

  • Special diaphragm: Viton and fluorosilicone are available.

  • Special seals: Viton, Teflon, and polyurethane are available.

  • If the ambient temperature exceeds 70 ° C, use the pilot separation type.

* Please contact us for details of optional specifications.

 

Asahi Enterprise Measurement and monitoring products

Asahi  Gap sensor 616 series

Gap sensor

616 series

Seating sensor for positive pressure

Gap sensor 616 is a precise gap detection switch that outputs an contact signal by detecting an object approaching the air ejection hole by changing the back pressure in the ejection hole.

There are 616J type with hysteresis less than 5μm, 616JX type with less than 1μm hysteresis, and 616A type with less than 0.05μm hysteresis.

The J and JX types use only air pressure for detection, so no power supply is required. The output signal is taken out as a contact signal.

Since the 616A type uses a pressure sensor, a 24V power supply is required. An ON-OFF signal and an analog signal proportional to the gap are output.

Standard specifications

Asahi Model number

Asahi  Gap sensor 616J1

Asahi  Gap sensor 616J3

Asahi  Gap sensor 616JX1

Asahi  Gap sensor 616JX3

Asahi  Gap sensor N6S

Supply pressure

100-250kPa (600 option)

Detection gap (μm)

5 to 200

10 ~ 300

0 ~ 800

0 ~ 1200

~ 600

Hysteresis (μm)

~ 100≤5

~ 150≤10

~ 200≤1

~ 200≤1

~ 100≤0.05

~ 150≤10

~ 200≤20

~ 400≤5

~ 600 ≤ 10

~ 200≤0.1

~ 200≤20

~ 300≤30

~ 800 ≤ 20

~ 1200≤30

~ 600 ≤ 0.2

Connection diameter

G1 / 8 (Ps)

Conduit port

Pf1 / 2 (Din connector, protection class IP65)

R03R-R5F

Fluid used

air

Mounting direction

Any

Detection method

Diaphragm (Viton)

(SUS)

weight

500g

700g

400g

Output configuration

SPDT (Only a contact can be used with light)

0-6V

Rating specifications

1A / 250VAC, 1A / 20VDC

Open collector

Ambient temperature

0-80 ° C

0-40 ° C

Asahi  Pressure transducer 601 series

Pressure transducer

601 series

Pressure-Pressure Transmitter / Flow-Pressure Transmitter

The flow rate sensor 601D is a high-speed, high-resolution flow rate sensor that is used as an internal or external package for the 900 series and 940 series.

Rangeability 1/20 Flow rate can be measured from minimum flow rate 0.1 CCPM to maximum flow rate 300 LPM. (Pure water conversion)

There are the 601D-D series that uses a differential pressure sensor that comes in direct contact with liquid (wetted parts material = SUS316L) and the 601D-R series (patented) that uses a sensor that does not come into contact with the measuring fluid. Both sensors measure the differential pressure between two points to calculate the flow rate, and the calculation result is linearized and output.

Stable high-speed closed-loop control is possible because it has a calculation speed of 1 msec or less.

Standard specifications

Asahi Model number

Asahi  Pressure transducer 601D-D05

Asahi  Pressure transducer 601D-D2

Asahi  Pressure transducer 601D-D10

Asahi  Pressure transducer 601D-R05

Asahi  Pressure transducer 601D-D25 *

Line pressure (kPa)

100 ~ 300

Detected flow rate (CCPM)

5 ~ 100

100-2000

2500-50000

10 ~ 100

200-2000

Port size (G)

1/4

3/8

1/2

1/4

3/8

Conduit port

R03R-R5F

Fluid used

Liquid compatible with SUS316

Any

Mounting direction

Any

Detection method

Differential pressure measurement

weight

700g

600g

Power supply

24V

Analog output

0-5V

Ambient temperature

0-40 ° C

NOTE

* 1 -The 601D-R series requires a supply pressure of maximum line pressure + 50kPa.

 * Please contact us for detailed dimensions and characteristic data.

 

Asahi Enterprise Orderable products

Asahi  Digital regulator S670 series

Digital Regulator

S670 series

Package type for positive pressure and secondary pressure control

The supply pressure (primary pressure) is reduced and the output pressure (secondary pressure) is controlled to be constant.

The S670 series has all the functions required for pressure control built into the DIN96 body.

A 4-digit digital switch for local setting, an analog remote setting input, a 4-digit LED display for displaying the set value and the actual pressure, etc., realizes highly accurate pressure control simply by connecting the pressure source and power supply.

Standard specifications

Asahi Model number

Asahi Digital regulator S670S0.3

Asahi Digital regu latorS670S1

Asahi Digital regulator S670S2

Asahi Digital regulator S670S7

Set pressure

0.15 ~ 30.00kPa

0.5 ~ 100.00kPa

1 ~ 200.0kPa

3.5 ~ 700.0kPa

Power supply

24 VDC

Fluid used

Dry air

Maximum supply pressure

150kPa

200 kPa

400kPa

1000kPa

Minimum supply pressure

60kPa

140kPa

220kPa

720kPa

I / O connection

Φ6 tube one-touch fitting

Output flow rate

0 ~ 50nL / min

Pressure sensor

Piezoresistive silicon sensor

display

4 digits (character height 10 mm LED)

Overall accuracy

± 1% FS or less

response speed

5 sec or less

Operating temperature limit

0-40 ° C

Pressure setting method

4-digit digital switch, remote terminal analog input (switch)

Remote input * 1

0-5V, 0-10V, 4-20mA

External dimensions

96x96x138.5mm (excluding protrusions)

weight

1.2 kg

accessories

AC adapter, instruction manual

NOTE

* 1 -The last digit is added to the model number. 1 = 0 to 5V / 2 = 0 to 10V / 3 = 4 to 20mA

 * Please contact us for detailed dimensions and characteristic data.

 

Asahi  Reference pressure generator S650 series

Reference pressure generator
Standard Pressure Generator

S650 series

High precision type for positive and negative pressure control

The supply pressure (primary pressure) is reduced and the output pressure (secondary pressure) is controlled to be constant. The S650 series has all the functions required for ultra-precision pressure control built-in, and you can select the optimum content for your application such as pressure range and accuracy.

A 5-digit push button switch for performing local settings, an analog remote setting input, a 5-digit LED display for displaying the set value and actual pressure, etc. realizes highly accurate pressure control simply by connecting the pressure source and power supply. ..

Standard specifications

Asahi Model number

Asahi Pressure Generator  S650SML

Asahi Pressure Generator S650SMH

Set pressure * 1

3.5 ~ 700kPa

12.5 ~ 2500kPa

Setting unit

0.01 kPa

0.1kPa

input signal

0-10V

Supply pressure

800 ± 20kPa

3000 ± 200kPa

Accuracy * 2

± 0.14% FS

Mounting direction

Regular only

Temperature effect Zero point * 2

± 0.018% FS

Temperature effect Span * 2

± 0.018% FS

Pressure display

5 digits (0.01kPa)

5 digits (0.1 kPa)

Supply pressure source

Dry air

control method

Force balance + PI control

Pressure sensor

Variable capacitance sensor

Power supply

24 VDC

I / O connection

Rc1 / 4

Rc3 / 8

Orifice diameter

Φ4 mm

Φ11 mm

Flow rate consumed

1.5 L / min or less

Warm-up time

Half an hour

Operating temperature limit

5-40 ° C

Power supply

AC 100V

Insulation resistance

1 MΩ or more

External dimensions

280x210x133mm (excluding protrusions)

weight

About 3kg

accessories

Power cable, instruction manual

NOTE

* 1 - It can be arbitrarily selected, and details of shipping specifications are based on the finalized drawings.

* 2 - It depends on the accuracy of the pressure sensor used together.

 * Please contact us for detailed dimensions and characteristic data.

 

Türkiyede Asahi Enterprise ürünleri ile ilgili  uygun rekabetçi fiyatları almak için müşteri temsilcimiz ile  http://www.imajteknik.com.tr/bize-ulasin veya Fiyat teklifi formunu  doldurarak mesaj bırakmanız halinde satış mühendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.

Asahi Enterprise markasına ait tüm ürünler

    0 kayıt bulundu

      ALFABETİK MARKA LİSTESİ

      Sertifikalarımız

      Oruçreis Mah. Tekstilkent Tic. Mrk.
      G2 Blok, No:101 (10AD-Z77)
      34235 Esenler / ISTANBUL
      T: +90 212 235 95 35 / 36
      F: +90 212 235 95 37

      info@imajteknik.com

      E-Bülten Listemize üye olun !

      Gelişmelerden haberdan olmak ve ileride gerçekleştirilecek yeniliklerimizden haberdan olabilmek için e-posta adresinizi bizimle paylaşın!