Level Alarm System - Type OAS-5
For high level and overfill
OAS 5 with sensors, is a complete level alarm system required
either as an independent Overfill or High level and Overfill
system on all type of tankers. When delivered as a dual point
system it is approved as two independent systems as required
in the regulations.
Vapour alarm system – Type OVS 2.1
For vapour return lines on tankers
Vapour alarm system OVS 2.1 OP monitors the oxygen content
and the pressure in the waste vapour line(s) during loading
of tank vessels. It consists of a detector cabinet mounted
on deck with Eex ia approved oxygen and pressure sensors,
flow fail initiator, manifold selector, test and purge facility. The
electronic cabinet mounted in the cargo control room with alarm
panel has individual LED displays and alarm status LEDs.
Different models cover all configurations of manifolds and
vapour lines.
Gas sampling system – Type OGS 3.1 and OGS 3.11
For total solutions in gas sampling
OGS 3.1 is our advance model for special requirements. Different
models and options cover most applications you will find
onboard any kind of tankers with special needs. All delivered
parts are completely assembled ready for interconnection to
on-site application. OGS 3.1 is based on a scanning method,
which means that sample points are being connected to
sensor(s) in a cyclic sequence. The operator panel has LCD
display and individual LED lamps indicating each measuring
point status. To minimize scanning cycle time and guarantee
fresh samples at all times, the system has two vacuum pumps.
One main pump, continuously sucking from all sample points
and a smaller sample pump taking samples from the actual
point according to the sequence. This insures quick response
if gas is detected. Purging of sample line is done immediately
after each sampling is finished.
Fixed gas detection system - Type OGS 2.1
For cargo pump room and other
applications and type of vessels
Gas Alarm OGS 2.1 is a fixed detection system for
pump rooms, AC inlets (ISGOTT 5th edition) and other areas.
The sensors are based on Eex D approval. Most common gas
sensor types are hydrocarbon, oxygen and hydrogen-sulphide.
The system can independently handle infinite number of
sensors. Each alarm unit have individual display, 4 adjustable
independent alarm setpoints and posibilities for voting.
Furthermore, each alarm unit has separate alarm LEDS for
system/sensor failures.
Gas Alarm OGS 2.1 is a micro controller based gas
detection system for pump rooms. The system is complete with
sensors and connection points. The OGS 2.1can be delivered
as a split version with the alarm panel mounted in a separate
cabinet.
The alarm panel has individual displays, alarm LEDs for all
gasses, and system alarms. The system will be factory adjusted
to give an alarm at a specific gas level, but can easily be set to
other levels without any instruments. As standard are potential
free output relay contacts for power failure and common system
failure, in addition to a common relay for each gas type that
the system is configured for. The system also drives a bridge
remote alarm panel..
Multi alarm System - type au 2.1
For high level and overfill
OAS 5 with sensors, is a complete level alarm system required
either as an independent Overfill or High level and Overfill
system on all type of tankers. When delivered as a dual point
system it is approved as two independent systems as required
in the regulations.
Water Ingress System OAS WI
For high level and overfill
OAS 5 with sensors, is a complete level alarm system required
either as an independent Overfill or High level and Overfill
system on all type of tankers. When delivered as a dual point
system it is approved as two independent systems as required
in the regulations.
various products
Impact Personal Multi-gas Monitor
Portable multi-gas monitor for the protection of personnel from up to four hazardous gases simultaneously in the working environment.
Portable multi-gas monitor for the use onboard tankers for measuring the flammable gas concentration in VOL % and Oxygen level simultaneously in the working environment.
IMPACT PERSONAL MULTI-GAS MONITOR
Temperature Calibrator
Portable temperature calibrator for testing of temperature- sensors, indicators, switches and safety equipment. The heating medium is hot air. This makes it clean to use and it has quick temperature change response. Temperature range is about 10 degrees above ambient to + 700 degrees Celsius with digital readout of the measured temperature. The calibrator is type approved by DnV.
TYPE OTE-T700
Pressure Calibrators
Portable pressure calibrators for testing of pressuresensors, indicators, switches and safety equipment. The pressure medium is oil. It has fine adjustment of the pressure, and an overpressure relief valve. The digital readout can be selected to bar or PSI. Pressure range is 0 - 200 bar / 0-300 bar. The unit can also be delivered in Eex version.
TYPE OTE-P202 and OTE-P300
TYPE OTE-P300
Low Pressure / Medium Pressure Calibrators
Portable low pressure calibrator for testing of pressure- sensors, indicators, switches and safety equipment at a low pressure range.The calibrator can be delivered with either analogue or digital gauges. Kindly specify what type upon request and ordering.
TYPE LPT 1
TYPE TP 1
Alarm Lights
Alarm Light OAL -A2 is an alarm light designed for harsh outdoor mounting. The housing is of welded stainless steel. The lens is of polycarbonate and has an O-ring gasket to the housing. The electronic card is completely encapsulated in silicone rubber for moisture and vibration protection. The lower part of the housing functions as a junction box for cable connection.
This construction is especially suitable for marine applications.
TYPE OAL-A2
Alarm Light XB-11 is an alarm light designed for use in potentially explosive atmospheres and harsh environmental conditions. The housing is of UV stable glass reinforced polyester. This light is approved for connection (Eex approved connection) directly in hasardious area.
TYPE XB-11
Alarm Light XB-9 is an alarm light designed for use in potentially explosive atmospheres and harsh environmental conditions. The housing is of UV stable glass reinforced polyester.
TYPE XB-9
Alarm Horns
EEx Alarm horn DB-3 is an electrical alarm horn designed for use in potentially explosive atmospheres and harsh environmental conditions. The housing is of reinforced polyester. Mounting bracket is included.
TYPE DB-3
Alarm horn KTV 75/400 is an air driven alarm horn designed for use in potentially explosive atmospheres and harsh environmental conditions. The horn is delivered with mounting bracket, soleniod valve and air filter. The solenoid valve is non-EEx and must be mounted indoor, safe area.
TYPE KTV 75/400
Alarm horn A121 is an electrical alarm horn with very high output sounder.
TYPE A121
Alarm horn A105 is an electrical alarm horn.
TYPE A105
|