Daiichi Square-Type Pressure Gaugesmodel KKT
This is a general model with a square front panel of 10Ø
Mounting |
Connection |
Pressure range |
D: panel mounting |
G3/8B(PF)
R3/8(PT)
G1/2B(PF)
R1/2(PT) |
0.06~100MPa
(0.6~1000kgf/cm²) |
Frame: black or can be painted to order
Material: brass and stainless steel
Daiichi Duplex Pressure Gaugesmodel TWT
This model measure at 2 different points at the same time.
Size |
Mounting |
Connection |
Pressure range |
100
110
(square) |
B: flange type
C: trimmed rim type
D: panel mounting |
G3/8B(PF) |
0.06~10MPa
(0.6~100kgf/cm²) |
Material: brass
• The size indication is in diameter.
Daiichi Anti-Corrosion Pressure Gaugesmodel YKT
This models is excellent in anti-corrosion as the wetted parts are all made of fluoroplastics.
Size |
Mounting |
Connection |
Pressure range |
50
75 |
A: flangeless type |
R3/8 (PT) |
0.1•0.3•0.5
1•-0.1MPa |
Application: semiconductor, pharmaceutical, medical equipment, chemical, food, paint, purified fluid, etc.
Daiichi All Stainless Steel Type pressure Gaugesmodel US series
This model demonstrates high durability in severe enviroment.
Size |
Mounting |
Connection |
Pressure range |
60
75
100 |
A: flangeless type
B: flange type
D: panel mounting |
G1/4B(PF)
R1/4(PT)
G3/8B(PF)
R3/8 (PT)
G1/2B(PF)
R1/2(PT) |
0.06~100MPa
(0.6~1000kgf/cm²)
vacuum gauges
compound gauges |
Materials: stainless steel
Application: semiconductor, pharmaceutical, medical equipment, chemical, food, paint, purified fluid, etc.
NB. Connections and pressure ranges vary depending on the size.
• The size indication is in diameter.
Daiichi Pressure Gauges for Semiconductor Industrymodel KPT
This model is suitable for the measurement of highly corrosive fluid and can be used in severe enviroment such as corrosive atmosphere.
Size |
Mounting |
Connection |
Pressure range |
50
60 |
A: flangeless type
D: panel mounting |
VCR male 1/4
VCR nut 1/4
G1/4B(PF)
R1/4(PT) |
0.1~25MPa
(1~250kgf/cm²)
vacuum gauges
compound gauges |
Materials: stainless steel
Application: semiconductor, pharmaceutical, medical equipment, chemical, food, paint, purified fluid, etc.
NB. Connections and pressure ranges vary depending on the size.
• The size indication is in diameter.
Daiichi Edgewise Type Pressure Gaugesmodel DR series
This model is panel gauges of draft type for low pressure measurement
Mounting |
Connection |
Pressure range |
vertical type
horizontal type |
RC1/4
(PT female)
G3/8B(PF) |
0.3~30kPa
(30~3000mmH20) |
Material:brass and stainless steel
Daiichi Recording Pressure Gaugesmodel JK series
This model has a function of self-recording the time-lapse change of pressure
Size |
Mounting |
Connection |
Pressure range |
200
250
300 |
surface mounting
portable
panel mounting |
G3/8B(PF)
G1/2B(PF) |
1kPa~50MPa
(100mmAq~500kgf/cm²) |
Feed: hand-winding of electricity
One rotation: 12hr, 24hr and 168hr
Material: brass
Daiichi Small Pressure Transmittermodel LN series
This LAN series is a device for converting pressure variations into electrical signals (4~20mA at DC 24V) with fidelity..
Lead-wire models are available.
Mounting |
Connection |
Pressure range |
Output power |
terminal type(LTN)
lead wire type(LNW) |
G3/8B(PF) |
0~0.4MPa
(4kgf/cm²)
↓
0~0.40MPa
(400kgf/cm²) |
DC4~20mA
(DC24V)
2-wrire type |
LNT-2L: 5kPa→0.3MPa,
-0.1~0.3MPa are available.
Daiichi Digital Transmitter (Display Type)model LM series
This model is the transmitter of strain gauge system that digitally indicates pressure through 2 wires.
Type |
Connection |
Pressure range |
Output power |
box type pressure
transmitter (LMB) |
G3/8B(PF) |
0.4MPa
↓
0~50MPa |
DC4~20mA
(DC24V)
2-wrire type |
box type
differential Low
pressure
transmitter (LMS) |
tube
O.D. 0.6mm |
differential pressure
0~5kPa~0~14kPa
(500mmH20) (1400mmH20)
±2.5kPa~±5kPa
(±250mmH20) (±500mmH20) |
Daiichi Pressure Transmittermodel LB series
This is the transmitter of lianer-transmission system. The excellent durability of this model has been proven in severe condition on the boats and ships for many years.
Mounting |
Connection |
Pressure range |
Output power |
drum type
pressure
transmitter (LBD) |
G3/8B(PF) |
0~0.04MPa
(0.4kgf/cm²)
↓
0~40MPa
(400kgf/cm²) |
DC4~20mA
(DC24V)
2-wrire type |
LB-4LAC 4-wire model with 100V power supply can be made to order.
Daiichi Differential Transmittermodel LA series
This transmitter of lianer-transmission system can be used under the maximum line pressure of up to 3.5Mpa
Mounting |
Connection |
Pressure range |
Output power |
drum type
with differential
pressure
transmitter (LAE) |
G3/8B(PF)
X2 |
0~50kPa
(0.5kgf/cm²)
↓
0~1.6MPa
(16kgf/cm²) |
DC4~20mA
(DC24V)
2-wrire type |
❈ All connections are male, unless there is a remark of female.