Product group : Telemetry System IoT
Manufacturer : Exemys
Product : Cellular Telemetry System 3G
Type : GRD-3G
Telemetry Device with 3G + 2G Cellular / Satellite communication and Programmable Logic
GRD-3G
How does it work?
The GRD family of products helps control and supervise any kind of equipment from distance, be it a control system or process system facilitating the implementation of the remote telemetry systems.
The GRD family of products helps control and supervise any kind of equipment from distance, be it a control system or process system facilitating the implementation of the remote telemetry systems. Additionally it includes the possibility to load a text script to perform internal logics
General Features
-
3G + 2G Cellular Communication
-
American and Europena Bands
-
Satellite communication (optional)
-
4-20mA and 0-10V Inputs
-
Digital Inputs
-
Pulse Counter Inputs
-
Digital Outputs
-
Serial Ports
Models
MODELS
|
SERIAL PORT
|
ANALOG INPUTS
|
DIGITAL INPUTS
|
DIGITAL OUTPUTS
|
GRD1620-XF-3G
|
1 RS232 / 1 RS485
|
---
|
---
|
---
|
GRD3621-XF-3G
|
---
|
2 0-1V/0-10V/4-20mA
Configurables of Software
(1 PT100 input)
|
4 (4 for pulses of up to 50Hz)
Configurables of Software
|
GRD3625-XF-3G
|
1 RS232 / 1 RS485
|
4 0-1V/0-10V/4-20mA
Configurables of Software
|
6 (6 for pulses of up to 50Hz)
Configurables of Software
|
GRD3534-XF-3G
|
2 RS232 / RS485
|
8 Configurables
0-1V/0-10V/4-20mA
|
16
(8 for pulses of to 1KHz)
|
8
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : ZigBee Telemetry System
Type : wRemote
ZigBee Wireless Telemetry System 2.4GHz
wRemote
Description :
is a new concept of Wireless Telemetry, based on mesh networking technology.
How does it work?
The system consists of 2 devices, a Concentrator and Remote Nodes. All devices share a common data network, known as mesh networks.
General Features
- Models: Concentrator and Remote Nodes
- Suitable for industrial environments
- Communication IEEE 802.15.4 in 2.4GHz
- Mesh Network between devices
- Digital Inputs and Outputs
- Analog Inputs of 0-10V and 4-20mA
- Serial Port RS232/485 for Modbus slaves
- Port USB for Modbus slaves and configuration
- Access to I/O and Serial Port in Modbus
Models
MODELS
|
FUNCTION
|
SERIAL PORT
|
EXTRA
|
ANALOG INPUTS
|
ANALOG OUTPUTS
|
DIGITAL INPUTS
|
DIGITAL OUTPUTS
|
NODES
|
wRemote-1000-CN
|
Concentrator
|
RS232/
RS485
|
USB
|
---
|
---
|
---
|
---
|
50
|
wRemote-1500-ETH-CN
|
Concentrator
|
RS232/
RS485
|
USB/ETHERNET
|
---
|
---
|
---
|
---
|
50
|
wRemote-3005-ND
|
Node
|
RS232/
RS485
|
USB
|
4x Configurables 0-10V / 4-20mA
|
---
|
4
|
2
|
---
|
wRemote-5005-ND
|
Node
|
RS232/
RS485
|
USB
|
2x Configurables 0-10V / 4-20mA
|
2x Configurables 0-10V / 4-20mA
|
4
|
2
|
---
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Ethernet Telemetry System
Type : cLAN
MONITORING & CONTROL WITH ETHERNET TCP/IP
cLAN
How does it work?
Using the cLAN devices allows for remote monitoring and control of sensors, transducers, and intelligent devices from your own control system or through our Web Server for telemetry applications.
The cLAN helps control and upervise any kind of equipment from distance, be it a control system or process system facilitating the implementation of the remote telemetry systems. Additionally it includes the possibility to load a text script to perform internal logics.
General Features
- Ethernet Port.
- Digital Inputs and Outputs
- Pulse count inputs
- 0-1V, 0,10V, 4-20mA Analog Inputs
- Time stamped Data Logging
- Logic control using SCRIPT programming
- Modbus TCP and Serial slave for direct SCADA connection.
- NMEA 0183 and MetPak (Gill Instruments) support
- Free Port (user protocol parsing using script programming)
- Satellite module antenna (optional)
- FTP client to send logged data
- I/O expansion using embedded Modbus Master
- Transparent remote Access to serial port.
Models
MODELS
|
ETHERNET PORT
|
SERIAL PORT
|
DIGITAL INPUTS
|
DIGITAL OUTPUTS
|
ANALOG INPUTS
|
SCRIPT
|
EXPANSION I/O
|
CLAN-1520-XF
|
10/100 Mbit
|
2 Ports
RS232/485
|
---
|
---
|
---
|
yes
|
yes
|
CLAN-3524-XF
|
10/100 Mbit
|
2 Port
RS232/485
|
16
(8 pulse counter)
|
8
|
8
0-1V, 0-10V, 4-20mA
|
yes
|
yes
|
CLAN-1205-XF
|
10/100 Mbit
|
1 RS232
+ 1RS485
|
---
|
---
|
---
|
yes
|
yes
|
CLAN-2205-XF
|
10/100 Mbit
|
1 RS232
+ 1RS485
|
10 configurables
10 pulses
|
---
|
yes
|
yes
|
ERD-1101-XF
|
10/100 Mbit
|
1 RS232
+ 1RS485
|
---
|
---
|
---
|
no
|
no
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Wireless Radio 2.4GHz
Type : wSerial
WIRELESS RADIO 2.4GHz Mesh NETWORK TECHNOLOGY
wSerial
Description :
is a new concept in Serial Radio, which introduces Mesh Networks technology to achieve not only point to point, but also multiple connections.
The system was designed to be a real network of serial ports to industrial facilities where there is a need to gather information from remote and dispersed devices, reliably and inexpensively.
How it works?
The system consists of 2 devices. A Concentrator and Remote Nodes. All devices share a common data network, known as mesh networks.
General Features
- Models: Concentrator and Remote Nodes
- Suitable for Industrial environments
- Communication IEEE 802.15.4 in 2.4GHz
- Mesh Network between devices
- Serial Port RS232/485/USB
Models
MODELS
|
FUNCTION
|
SERIAL PORT
|
EXTRAS
|
WSerial-C
|
Concentrator
|
1x RS232/485
|
USB
|
WSerial-ETH-C
|
Concentrator
|
1x RS232/485
|
USB/ ETHERNET
|
WSerial-N
|
Node
|
1x RS232/485
|
USB
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Wireless Tunnel
Type : wTunnel
WIRELESS TUNNEL WITH ZIGBEE RADIO TECHNOLOGY
wTunnel
Description :
The system was designed to be a true Point to Point Tunnel to reflect conditions and field values, reliably and at low cost.
How does it work?
wTunnel is an innovative product that enables reflect device inputs as outputs in the other, completely wireless and through technology ZigBee 802.15.4 Radio.
The system was designed to be a true Point to Point Tunnel to reflect conditions and field values, reliably and at low cost.
General Features
-
Communication IEEE 802.15.4 in 2.4GHz
-
2 Analog Inputs, 0-10V and 4-20mA
-
2 Digital Inputs
-
2 Digital Outputs
-
1 Serial Port RS232/485/USB
Types of Tunnels
I/O Tunnel
With this tunnel can replicate the activation of an input as an output the other end, and vice versa.
0-10V and 4-20mA with Digital Output, Tunnel
2 values are set at the inputs of 0-10V or 4-20mA from one end, which they shoot at the other end, on or off, of a digital signal.
Serial Tunnel
It replicates the information flowing through the serial port on one end, on the other end. The device has a serial port RS232, RS485 or USB
Analog I/O Tunnel
The value of an input analog will be reflected in the analog output of the team remote.
Product group : Protocol Converters
Manufacturer : Exemys
Product : Modbus TCP to Serial
Type : EGW1-IA3-MB
SERIAL MODBUS CONVERTER TO MODBUS TCP with DIGITAL I/O's
EGW1-IA3-MB
Description
Is a protocol converter Modbus Serial (ASCII or RTU) To Modbus TCP
How does it work?
The EGW1-MB module is a device used to connect any industrial equipment with MODBUS RS232 / 485/422 communication, to An Ethernet TCP / IP network.
It also has its own digital inputs and outputs. This Characteristic makes it different from similar devices, since it provides An integrated solution for control applications without the need to Additional modules..
General Features
-
Modbus TCP, ASCII, RTU Protocols.
-
Modbus Master or Slave.
-
Up to 16 Connections Modbus TCP Simultaneously.
-
Selection of RS232/485/422 by software, up to 115 Kbps.
-
Digital I/O’s controlled by Modbus.
-
Install and set up via serial, Telnet or a Web Browser
-
Software for searching Exemys devices on the network.
-
DIN Rail mounting, temperature-resistant Industrial Case.
-
Industrial terminal blocks.
-
Wide range power supply 10 to 30 Vdc.
Models
PART NUMBER
|
OBSERVATIONS
|
EGW1-4B0-00-IA3-MB
|
4 RS232/RS485 Ports configurables
|
EGW1-1C0-00-IA3-MB-IS
|
1 RS232/RS485 port cofigurable isolated / RS422 isolated
|
EGW1-1C0-10C-IA3-MB-IS
|
1 RS232/RS485 port cofigurable isolated / RS422 isolated + 10 Digital I / O configurables
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Modbus serial to NMEA
Type : SGW1-IA3-MB-NM
MODBUS RTU/ASCII TO NMEA CONVERTER
SGW1-IA3-MB-NM
Description :
SGW1-IA3-MB-NM
Allows you to read NMEA 0183 data comming from a GPS or weather station using the industry standard protocol Modbus
General Features
-
2 RS232/ RS485 ports (1NMEA + 1 Modbus).
-
Modbus protocols RTU and ASCII.
-
Baud rates up to 115200 bps.
-
Easy to install and set-up through a serial console.
-
DIN Rail mounting, temperature-resistant Industrial Case.
-
Wide range power supply (+10 a 30Vdc)
-
USB configuration
Part number : SGW1-2B0-00-IA3-MB-NM
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Modbus to Hostlink
Type : SGW1-IA3-MB-HL
Modbus ASCII/RTU to Hostlink Converter
SGW1-IA3-MB-HL
Description :
SGW1-IA3-MB-HL
Converts an OMRON PLC (Hostlink® Protocol) into a Modbus ASCII/RTU Slave easily.
How does it work?
Using SGW1-IA3-MB-HL you can connect an OMRON® PLC to a Modbus Network. Protocol conversion is based on easy-to-fill translation tables. EG: You can read OMRON® registers DM0100 to DM0199 through Modbus registers 40100 to 40199.
General Features
-
DIN Rail mounting, temperature-resistant Industrial Case.
-
2 serial ports (1 Modbus + 1 Hostlink)
-
Modbus ASCII and RTU protocols.
-
Hostlink protocol configurable.
-
Allows several Hostlink Slaves connected to only one SGW1-MB-HL.
-
Baud rates up to 115200 bps.
-
Easy to install and set-up through a serial console.
-
Wide range power supply (10-30V DC).
-
Easy Serial Ports Configuration.
Part number : SGW1-2B0-00-IA3-MB-HL
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Modbus ASCII to RTU
Type : SGW1-IA3-MMP
PORTS MODBUS MULTIPLEXER & CONVERTER
SGW1-IA3-MMP
Description
The SGW1-IA3-MMP is a multifunction device, which allows Multiplexing, Conversion and Data Exchange between Modbus Serial devices..
How does it work?
The SGW1-IA3-MMP, is a multifunction device that allows to perform the following functions:
1) Modbus Port Multiplexing (Masters and Slaves)
2) Conversion of Modbus ASCII data to Modbus RTU, with different Baud Rates and with RS232 or RS485 ports
3) Exchange of Registers between Modbus Masters, by means of an exchange memory
General Features
-
Up to 3 ports to connect Masters.
-
Up to 3 ports to connect Slaves.
-
No need of registers tables.
-
DIN Rail mounting.
-
Wide range power supply, 10 to 30 Vdc.
-
Easy configuration.
-
Industrial pluggable terminal blocks.
-
USB Configuration
Models
MODELS
|
DETAILS
|
SGW1-4B0-00-IA3-MMP
|
4 RS232/RS485 ports configurables
|
SGW1-13B0-00-IA3-MMP-CF
|
1 configurable RS232 with RTS for radio control + 3 RS232/RS485 ports configurables
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Multiplexer Modbus
Type : SGW1-IA3-MMP
PORTS MODBUS MULTIPLEXER & CONVERTER
SGW1-IA3-MMP
Description
The SGW1-IA3-MMP is a multifunction device, which allows Multiplexing, Conversion and Data Exchange between Modbus Serial devices..
How does it work?
The SGW1-IA3-MMP, is a multifunction device that allows to perform the following functions:
1) Modbus Port Multiplexing (Masters and Slaves)
2) Conversion of Modbus ASCII data to Modbus RTU, with different Baud Rates and with RS232 or RS485 ports
3) Exchange of Registers between Modbus Masters, by means of an exchange memory
General Features
-
Up to 3 ports to connect Masters.
-
Up to 3 ports to connect Slaves.
-
No need of registers tables.
-
DIN Rail mounting.
-
Wide range power supply, 10 to 30 Vdc.
-
Easy configuration.
-
Industrial pluggable terminal blocks.
-
USB Configuration
Models
MODELS
|
DETAILS
|
SGW1-4B0-00-IA3-MMP
|
4 RS232/RS485 ports configurables
|
SGW1-13B0-00-IA3-MMP-CF
|
1 configurable RS232 with RTS for radio control + 3 RS232/RS485 ports configurables
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : HART to Modbus
Type : EGW1-MB-HT
Description
The EGW1-IA3-MB module, is a protocol converter HART to Modbus TCP, RTU and ASCII
How does it work?
The EGW1-MB-HT- module is a device used to connect any industrial equipment with HART communication to one or more Modbus TCP or Modbus Series masters (RTU / ASCII)
The equipment has 3 independent Modbus ports. One Ethernet for Modbus TCP, one RS232 another RS485 opto-isolated for Modbus RTU / ASCII
General Features
-
Modbus protocols TCP, RTU Y ASCII.
-
Up to 16 simultaneous Modbus TCP connections.
-
Modbus RS232 Port slave
-
TCP/IP Modbus port
-
Modbus RS485 slave port optoisolated independent of the RS232.
-
Installation and configuration by Web browser.
-
Software to search for Exemys devices in the network.
-
DIN Rail mounting, temperature-resistant Industrial Case.
-
ndustrial terminal blocks.
-
Wide range power supply 10 to 30 Vdc.
Models
PART NUMBER
|
OBSERVATIONS
|
EGW1-110-3-IA3-MB-HT
|
3 Ports HART / 1 Port RS232 / 1 Port RS485 isolated
1 Port 10/100 Mbps Ethernet
|
Datasheet pdf
Get a Quote / More ınfo
Product group :Serial Servers
Manufacturer : Exemys
Product : Industrial Serial Server
Type : SSE232-IA3
INDUSTRIAL SERIAL SERVER
SSE232-IA3
Description
It is a device that can connect any serial device (RS232 / 485/422) to an Ethernet Network
How does it work?
SSE232-IA3 Is an Ethernet communications device that can connect any serial device (RS232/RS485/RS422) to a Standard Ethernet network. Now, you can connect two remote RS232 devices through an Ethernet network. In addition, you can get remote access to those devices from a PC.
As a special feature, the SSE232-IA has built-in digital inputs / outputs. This feature is different from similar devices, as it provides a comprehensive solution for remote control applications, without the need for additional input / output modules.
General Features
DIN rail mounting, temperature-resistant Industrial Case.
Wide range power supply (10 to 30 Volts DC).
Industrial pluggable terminal blocks.
Automated recovery in case of lost communication.
COM Port redirector software enables existing software Applications to access connected devices.
Digital Input Notification through SNMP traps. SNMP Digital Outputs control.
Easy Web browser configuration.
Device search utility.
Models
PART NUMBER
|
DETAILS
|
SSE232-400-00-IA3-CF
|
4 RS232 ports with flow control
|
SSE232-4B0-00-IA3
|
4 configurable RS232/RS485 ports5
|
SSE232-1C0-00-IA3-IS
|
1 configurable RS232/Isolated RS485 / Isolated RS422 (half-duplex)
|
SSE232-1C0-10C-IA3-IS
|
1 configurable RS232/Isolated RS485 / Isolated RS422 + 10 configurable digital inputs/outputs
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Serial to Ethernet Converter Server
Type : SSE232-LE
SERIAL TO ETHERNET CONVERTER
SSE232-1B0-00-LE
RS232/RS485 to Ethernet 10/100 BaseT
How does it work?
SSE232-LE is an Etherhet communication device that provides Ethernet connectivity to your legacy serial link (RS232/RS485)
Now you can connect two devices linked with RS232/RS485 through an Ethernet network. Moreover, you will be able to gain access to these devices from a computer.
Characteristics :
-
Wide range power supply: 10-30 Vdc.
-
10/100 Base T Ethernet port
-
RS232 on male DB9
-
RS485 on terminal block
-
DIN rail mouting
-
Easy web-based password-protected configuration
-
Statistics and monitoring by web
-
Automatic link recovery after communication failures.
-
SNMP protocol support
Models
PART NUMBER
|
ETHERNET
|
RS232 IN DB9
|
RS485 IN BORNES
|
SSE232-1B0-00-LE
|
10/100 BaseT
|
1
|
1
|
Datasheet pdf
Get a Quote / More ınfo
Product group :Media Converters
Manufacturer : Exemys
Product : Converters RS232 & RS485
Type : MCV2
MCV2-C485-IA /MCV2-A485-IA /MCV2-A232-IA /MCV2-A485-CR /MCV2-C485-CR /MCV1-FO-SER /MCV1-FO-ETH /PS-485 /
CONVERTER & ISOLATOR RS232 / RS485
MCV2
Serial Converter RS232 to RS485/422 | MCV2-C485
General Features
-
Industrial fireproof case with assembly for DIN rail
-
Industrial fireproof case with assembly for DIN rail Galvanic Isolation, up to 2500 Vrms (1 minute)
-
DC Power input: +10 to +30 VDC.
-
Leds indication for power and flow of information
-
Polarity Resistors included
-
Removable terminal blocks connectors
-
Baud rate up to 115200 bps
-
Up to 32 nodes
-
Protection against surges, in line RS485 and RS422
Code:
MCV2-C485-IA-IS Converter RS232 a R485 /422 Isalator
Datasheet pdf
Get a Quote / More ınfo
RS485 Isolator (Galvanic Isolation) | MCV2-A485
General Features
-
Galvanic Isolation, up to 2500 Vrms (1 minute)
-
Automatic flow data control
-
DC Power input: +10 a 30 VDC.
-
Leds indication for power and flow of information.
-
Removable terminal blocks connectors
-
Baud rate up to 115200 bps
-
32 nodes on a single network.
-
Surge protection for RS485 line
-
Operating Temperature: -5 a 65 ºC, storage temperature: -40 a 75ºC
-
Industrial fireproof case with assembly for DIN rail
Code : MCV2-A485-IA-IS
Datasheet pdf
Get a Quote / More ınfo
RS232 Isolator (Galvanic Isolation) | MCV2-A232
General Features
-
Galvanic Isolation, up to 2500 Vrms (1 minute)
-
With RTS and CTS lines
-
DC Power input: +10 a 30 VDC.
-
Leds indication for power and flow of information
-
Removable terminal blocks connectors
-
Baud rate up to 115200 bps
-
Operating Temperature: -5 a 65 ºC, storage temperature: -40 a 75ºC
-
Industrial fireproof case with assembly for DIN rail
Code :MCV2-A232-IA-IS
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Serial to Fiber optics
Type : MCV1-FO-SER
Fiber optic to Serial
MCV1-FO-SER
Industrial Fiber Optic to Serial Converter.
How does it work?
The MCV1-FO-SER is an Industrial Multimode Fiber Optic to Serial converter, that allows to extend the communications up to 2.7 Km And without interferences for electrical noise
General Features
-
Serial Port: RS232, RS485, RS422 (Not simultaneous)
-
Fiber Optic Port: Transmitter & Receptor
-
Fiber Optic Connector: ST
-
Power Supply: +10/30 Vdc. Power ON LED
-
Case: DIN Rail Mountable, Fireproof
-
Maximum Distance: 2.7 Km
-
Baud rate: Up to 115200 bps
-
Fiber Optic supported: Multimode 50/125 um or 62.5/125 um
-
Wave Length: 820 nm
-
Max. Current: 150mA @ 10V, 75mA @ 30V
Models : MCV1-FO-SER-ST-MU (Multimode) (ST Connectors)
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Ethernet to Fiber opticst
Type : MCV1-FO-ETH
ETHERNET FIBER OPTIC (monomode y singlemode)
MCV1-FO-ETH
Ethernet to Fiber optic media Converter
How does it work?
MCV1-FO-ETH is an Industrial 10/100 Mbps Ethernet to fiber optics converter. It’s commonly used to interconnect industrial devices PLC’s, workstations, routers and servers. Its industral enclousure and 10 to 30Vdc supply input makes it the best option for industrial applications.
General Features
-
Operation Mode: Multimode or Singlemode
-
Ethernet Port: 10/100 Base TX, RJ45 connector
-
Fiber Port: 100 Base FX, ST or SC connector (Multimode) - 100 Base LX10, SC connector (Singlemode)
-
Power Input: +10 a +30 Vdc / 200mA max.
-
Operation temperature: 0 to 70° C
-
Enclosure: DIN Rail Mount, Ignifuge
-
Distance: 2 Km on Multimode and 10 Km on Singlemode
-
Wave Lenght: 1300nm
-
Protocol: CSMA/CD, Autocross over
Models :
-
MCV1-FO-ETH-ST-MU (Multimode) (Connector ST)
-
MCV1-FO-ETH-SC-MU (Multimode) (Connector SC)
-
MCV1-FO-ETH-SC-SI (Singlemode) (Connector SC)
Datasheet pdf
Get a Quote / More ınfo
Product group :Data logger
4-20mA, 0-10V, Digital I/O
Manufacturer : Exemys
Product : With Cellular / Satellite communication
Type : GRD-3G
Telemetry Device with 3G + 2G Cellular / Satellite communication and Programmable Logic
GRD-3G
How does it work?
The GRD family of products helps control and supervise any kind of equipment from distance, be it a control system or process system facilitating the implementation of the remote telemetry systems.
The GRD family of products helps control and supervise any kind of equipment from distance, be it a control system or process system facilitating the implementation of the remote telemetry systems. Additionally it includes the possibility to load a text script to perform internal logics
General Features
-
3G + 2G Cellular Communication
-
American and Europena Bands
-
Satellite communication (optional)
-
4-20mA and 0-10V Inputs
-
Digital Inputs
-
Pulse Counter Inputs
-
Digital Outputs
-
Serial Ports
Models
MODELS
|
SERIAL PORT
|
ANALOG INPUTS
|
DIGITAL INPUTS
|
DIGITAL OUTPUTS
|
GRD1620-XF-3G
|
1 RS232 / 1 RS485
|
---
|
---
|
---
|
GRD3621-XF-3G
|
---
|
2 0-1V/0-10V/4-20mA
Configurables of Software
(1 PT100 input)
|
4 (4 for pulses of up to 50Hz)
Configurables of Software
|
GRD3625-XF-3G
|
1 RS232 / 1 RS485
|
4 0-1V/0-10V/4-20mA
Configurables of Software
|
6 (6 for pulses of up to 50Hz)
Configurables of Software
|
GRD3534-XF-3G
|
2 RS232 / RS485
|
8 Configurables
0-1V/0-10V/4-20mA
|
16
(8 for pulses of to 1KHz)
|
8
|
Datasheet pdf
Get a Quote / More ınfo
Product group :I/O Module
4-20mA, 0-10V, Digital I/O
Manufacturer : Exemys
Product : With Modbus communication
Type : RMS1
ANALOG ACQUISITION MODULES
RMS1
Description :
RMS1 is a family of analog acquisition modules, with serial communication in Modbus protocols ASCII/RTU or Hostlink (Omron®)
How does it work?
Using RMS1, it's possible to acquire in an accurate and unexpensive way, analog variables such as Voltage, Current, Temperature, through serial protocols like Modbus ASCII/RTU or Hostlink (Omron®). It provides an integral solution to remote monitoring application, without the need to add additional modules
General Features
-
8 differential input channels:
- Current: 4-20 ma (12 bits)
- Voltage: 0-10 Vdc (12 bits)
- Temperature, PT100 (0.1 ºC)
- Temperature, Thermocouples J,K,T,R,N,E,S (0.1 ºC)
-
Configurable serial protocol - Modbus ASCII/RTU slave.
- Hostlink master (OMRON®)
-
Wide range of power supply, from 10 up to 30 Vdc
-
Easy configuration
-
Industrial pluggable terminal blocks
-
DIN rail mounting
Examples of use
- Analog sensors general systems
- Remote systems monitoring
- Industrial automation
- PLCs and SCADA systems
Models
MODELS
|
INPUTS
|
PROTOCOLS
|
SERIAL PORTS
|
INPUTS
|
RMS1-AI-110-00-80-IA3-MBHL
|
8
|
MODBUS ASCII / RTU (Slave)
HOSTLINK (Master)
|
1 RS232
1 RS485
|
4-20mA 0-10V.
|
RMS1-TC-110-00-80-IA3-MBHL
|
8
|
MODBUS ASCII / RTU (Slave)
HOSTLINK (Master)
|
1 RS232
1 RS485
|
Thermocouple
J,K,T,R,N,E,S
|
RMS1-PT-110-00-80-IA3-MBHL
|
8
|
MODBUS ASCII / RTU (Slave)
HOSTLINK (Master)
|
1 RS232
1 RS485
|
PT100
|
Datasheet pdf
Get a Quote / More ınfo
Product group : Analog/Digital Acquisition
4-20mA, 0-10V
Manufacturer : Exemys
Product : With Ethernet communication
Type :RME2-AI
ANALOG ACQUISITION MODULES
RME2-AI
Analog Acquisition Modules with multiple Communication Protocols
How does it work?
With RME2-AI, you can acquired analog variables through the network in an accurate way. The devices can convert Current and Voltage. This variables can be read in five different ways simultaneously (Modbus TCP, Web Page HTTP, SNMP, CSV and XML).
General Features :
-
8 Configurable analog differential inputs:
- Current, 4-20mA
- Voltage, 0-10 V
-
5 Protocols:
- Modbus TCP
- Web Page (HTTP)
- SNMP (V1)
- CVS / XML
- XML (HTTP)
Application :
-
Analog sensors supervision.
-
Battery voltage monitoring.
-
Data acquisition general application.
-
Remote monitoring systems.
-
PLC and SCADA systems.
-
Industrial automation.
-
Data center monitoring
Models
MODELS
|
DESCRIPTION
|
RME2-AI-100-00-80-IA3
|
1 RS-232 port
8 0-10 V / 4-20 mA inputs
10/100 Mbps Ethernet port
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : With Modbus Serial communication
Type :RMS2-AI
ANALOG ACQUISITION MODULES
RMS2-AI
RMS2-AI is a family of analog acquisition modules, with serial communication in Modbus protocols ASCII/RTU Slave
How does it work?
Using RMS2-AI, it's possible to acquire in an accurate way, analog variables such as Voltage and Current, through serial protocols like Modbus ASCII/RTU . It provides an integral solution to remote monitoring application, without the need to add additional modules.
General Features :
8 differential input channels:
- Current: 4-20 ma (12 bits)
- Voltage: 0-10 Vdc (12 bits)
Examples of use
Models
MODELS
|
DESCRIPTION
|
RMS2-AI-110-00-80-IA3-MB
|
1 port RS-232 / RS-485 Isolated
8 inputs 4-20 mA / 0-10 V.
|
Datasheet pdf
Get a Quote / More ınfo
Product group :PT100
Manufacturer : Exemys
Product : With Ethernet communication
Type : RME1-PT
ANALOG ACQUISITION MODULES
RME1-PT
Analog Acquisition Modules with multiple Communication Protocols
How does it work?
With RME1-PT, you can acquire temperatures from PT100 sensor. This variables can be read in five different ways simultaneously (Modbus TCP, Web Page HTTP, SNMP, CSV and XML).
General Features :
-
8 analog differential inputs
-
- PT100 sensor temperature
-
5 Protocols :
-
- Modbus TCP
- Web Page (HTTP)
- SNMP (V1)
- CVS / XML
- XML (HTTP)
Application :
-
Analog sensors supervision.
-
Battery voltage monitoring.
-
Data acquisition general application.
-
Remote monitoring systems.
-
PLC and SCADA systems.
-
Industrial automation.
-
Data center monitoring
Models
MODELS
|
INPUTS
|
PROTOCOLS
|
SERIAL PORTS
|
RME1-PT-100-00-80-IA3
|
8
|
See specifications
|
1 RS232
|
Datasheet pdf
Get a Quote / More ınfo
Product group :With Modbus Serial communication
Manufacturer : Exemys
Product : With Modbus Serial communication
Type : RMS2-PT
ANALOG ACQUISITION MODULES
RMS2-PT
RMS2-PT is a temperature analog acquisition module, with serial communication in Modbus protocols ASCII/RTU Slave.
How does it work?
Using the RMS2-PT, you can acquire PT100 sensor temperatures and transmit the acquired data through serial protocols like Modbus ASCII/RTU .
General Features :
Examples of use
Models
MODELS
|
DESCRIPTION
|
RMS2-PT-110-00-80-IA3-MBHL
|
1 port RS-232 / RS-485 Isolated
8 inputs PT100
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : With Ethernet communication
Type : RME1-TC
ANALOG ACQUISITION MODULES
RME1-TC
Analog Acquisition Modules with multiple Communication Protocols
How does it work?
With RME1-TC, you can acquire Temperatures from thermocouples. This variables can be read in five different ways simultaneously (Modbus TCP, Web Page HTTP, SNMP, CSV and XML).
General Features :
-
8 Configurable analog differential inputs:
-
- Thermocouple J,K,T,R,N,E,S
-
5 Protocols
- Modbus TCP
- Web Page (HTTP)
- SNMP (V1)
- CVS / XML
- XML (HTTP)
Application :
-
Analog sensors supervision.
-
Battery voltage monitoring.
-
Data acquisition general application.
-
Remote monitoring systems.
-
PLC and SCADA systems.
-
Industrial automation.
-
Data center monitoring
Models
MODELS
|
INPUTS
|
PROTOCOLS
|
SERIAL PORTS
|
RME1-TC-100-00-80-IA3
|
8
|
See specifications
|
1 RS232
|
Datasheet pdf
Get a Quote / More ınfo
Manufacturer : Exemys
Product : Digital I/O
Type : RMS1-GR
DIGITAL & ANALOG I/O IN MODBUS SERIAL
RMS1-GR
The RMS1-GR allows the expansion of the number of digital and analog inputs and outputs of any control or automation system handled from the Modbus Serial protocol (ASCII or RTU)
General Features :
-
Up to 16 Relay or Transistor outputs
-
Up to 16 Transistor or Opto-Isolated inputs
-
Up to 6 Analog Inputs (0-10V)
-
Power supply of 10 to 30Vdc
-
RS232 or RS485 Serial Port.
-
Simple configuration
Models :
Datasheet pdf
Get a Quote / More ınfo
Product group : 4-20mA, 0-10V, analog çıkış, Dijital
Manufacturer : Exemys
Product : With Modbus Serial communication
Type : RMS1-RM
DIGITAL AND ANALOG I/O MODBUS DEVICE
RMS1-RM
RMS1-RM is a family of digital and analog input and output devices, with communication by Modbus Protocol (RTU/ASCII)i
How does it work?
The RMS1-GR allows the expansion of the number of digital and analog inputs and outputs of any control or automation system handled from the Modbus protocol (RTU/ASCII) It can operate as a pulse counter on its digital inputs. It may also create an I/O "tunnel" using the master mode.
General Features :
-
4 digital inputs (standard inputs and pulse counters)
-
2 digital outputs
-
Up to 4 analog inputs (0-10V and 4-20mA)
-
Up to 2 analog outputs (0-10V and 4-20mA)
-
Power supply of 10 to 30Vdc
-
RS232/RS485 Serial Port
-
USB port configuration
-
Modbus RTU/ASCII slave
-
Master mode to create I/O tunnel
-
Dimensions: 70 x 90 x 65 mm (HxWxD).
Models :
MODELS
|
PORTS
|
DIGITAL INPUTS (COUNTERS)
|
DIGITAL OUTPUTS
|
ANALOG INPUTS 0-10V / 4-20MA
|
ANALOG OUTPUTS 0-10V / 4-20MA
|
RMS1-TT-110-42-0X-RM-MB
|
RS232 RS485
|
4
|
2
|
---
|
---
|
RMS1-TT-110-42-4VI-RM-MB
|
RS232 RS485
|
4
|
2
|
4
|
---
|
RMS1-TT-110-42-2VI-2VI-RM-MB
|
RS232 RS485
|
4
|
2
|
2
|
2
|
RMS1-TT-110-42-2VI-2VI-RM-MB-BAT
|
RS232 RS485
|
4
|
1 input 0-14V/4-20mA
1 input 0-28V/4-20mA
|
2
|
2
|
Datasheet pdf
Get a Quote / More ınfo
Product group : GPS Industrial Modbu
Manufacturer : Exemys
Type : GPS-MB
GPS INDUSTRIAL MODBUS SLAVE
GPS-MB
The GPS-110-MB-PS is an Industrial GPS with Modbus communication. It has two serial ports, one RS232 port for configuration and reading of NMEA sentences, and an RS485 Modbus Slave port to obtain all the data generated by the GPS (Latitude, Length, Speed, Hour, etc.) using modbus registers
General Features :
- GPS, Galileo and Glonass Constellations
- 1 RS485 Modbus port ASCII/RTU slave for GPS data
- 1 RS232 port for configuration and NMEA data 0183
- Leds Status Indicators
- With Magnetic Antenna and 3m long cable
- Power supply from +10 to +30 Vdc
- Industrial Assembly DIN-rail
Models :GPS-110-MB-PS
Datasheet pdf
Get a Quote / More ınfo
Product group : IDetector
Manufacturer : Exemys
Product : With Modbus Serial communication
Type : IDX
Inductive Vehicle Detector
How does it work?
The principle of operation of the equipment consists of the detection of a metallic mass by means of the measurement of inductance of a detection coil. The coil is part of an oscillator circuit that generates a magnetic field. When this field is crossed by a vehicle, the oscillator frequency changes. This variation is detected by a microprocessor circuit that determines, based on the equipment configuration, if the exit signal must be generated.
General Features :
-
Microcontroller.
-
1 or 2 channels.
-
Switching power supply.
-
4 settable sensibility levels.
-
4 settable frequency levels.
-
Optoisolated, relay, transistor or digital outputs (TTL).
-
Safe output in case of failure.
-
Channel multiplexing.
-
Advanced failure analysis.
-
Auto-tuning.
-
Output while present
-
Drift compensation due to environmental fluctuations
Application :
- Toll stations
- Automatic barriers
- Intelligent traffic lights
- Traffic Access Control
- Vehicle counting
- Speed measurements
- Traffic flow's direction
Models :
MODELS
|
OUTPUTS
|
CHANNELS
|
ID1-RL-0-NA-P
|
Normally Open Relay
|
1
|
ID2-RL-0-NA-P
|
Normally Open Relay
|
2
|
ID1-TR-0-NOFF-P
|
Transistor Normally OFF
|
1
|
ID2-TR-0-NOFF-P
|
Transistor Normally OFF
|
2
|
ID1-OP-0-NOFF-P
|
Optoisolated Normally OFF
|
1
|
ID2-OP-0-NOFF-P
|
Optoisolated Normally OFF
|
2
|