INDUcoder Messtechnik
Absolute encoder
Absolute encoders you will find as a single- or multi-turn encoder with up to 30-bit total resolution, as a shaft encoder or a hollow shaft encoder with push-on or through hollow shaft . The sizes of the encoder be 36 mm to 58 mm. Shaft encoders with diameters of 6mm and 10 mm, made hollow shaft encoder with the diameters of 5 mm to 15 mm.
We offer both the data output in Gray and binary code. There are all common fieldbus interfaces such as CAN bus, PROFIBUS, ETHERNET Powerlink, INTERBUS, and SSI, parallel push-pull interfaces.
Our absolute encoder NAM/NAH in the 58 mm size is offered in a stainless steel housing. The possible protection types of encoders are IP 50 to IP 67.
The majority of our absolute encoders can in our manual encoder , in the ROBUST ENCODER SYSTEM AWG / AWS and the cable - encoders are built on and should also be operated with our display modules.
We measure angles and distances.
Digital. Absolute and incremental.
INDUcoder Messtechnik GmbH in Duisburg develops, manufactures and markets electronic components for automation of the manufacturing industry in all sectors, in particular mechanical and plant engineering, heavy industry, food industry and research and development.
INDUcoder Absolute Encoder
INDUcoder Euro Absolut Encoder EA 36 / EAM 36
Ürün resmi |
Method |
Case diameter |
|
Resolution |
INDUcoder Euro Absolut Encoder
|
Magnetic absolute
|
ø 36 mm
|
ø 6 mm
|
8192 = 13 bit
4096 = 12 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 54
|
ø 36 mm
|
|
-30 ... +70°C
|
INDUcoder
Absolut Encoder EA 57
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
4096 = 12 bits
8192 = 13 bits
65536 = 16 bits
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
-40 ... +85°C
|
INDUcoder
Absolut Encoder EA 58 / EAS 58 Parallel
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
65536 = 16 Bits, 8192 = 13 Bits, 4096 = 12 Bits
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
|
INDUcoder
Absolut Encoder EA 59Z Parallel
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
1024 = 10 bit
4096 = 12 bit
8192 = 13 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65
|
ø 58 mm
|
|
-30 ... +70°C
|
INDUcoder
Absolut Encoder EAS 65 / 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
65536 = 16 Bit, 8192 = 13 Bit, 4096 = 12 Bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 65 mm
|
|
-40 ... +85°C
|
INDUcoder
Absolut Encoder EAM 57 / EAMS 57 SSI
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
-40 ... +85°C
|
INDUcoder
Absolut Encoder EAM 58 Profibus
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
4096 Schritte/360° = 12 bit
8192 Schritte/360° = 13 bit
65536 Schritte/360° = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
-40 ... +85°C
|
INDUcoder
Absolut Encoder EAM 58 CANopen® / Device Net
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
4096 Schritte/360° = 12 bit
8192 Schritte/360° = 13 bit
65536 Schritte/360° = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
-40 ... +85°C
|
INDUcoder
Niro Absolut Encoder NAM 58 / NAMS 58 Profibus / CANopen® / Device Net
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
-40 ... +85°C
|
INDUcoder
Absolut Encoder EAM 58 / EAMS 58 Ethernet Powerlink
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
-0 ... +60°C
|
INDUcoder
Absolut Encoder EAM 58 Interbus
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 10 mm
|
4096 Schritte/360° = 12 Bits, 8192 Schritte/360° = 13 Bits
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
-0 ... +60°C
|
INDUcoder
Robust Encoder AWG 101 / EAM 58 Profibus / Canbus
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 100 mm
|
ø 10 mm
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
|
-40 ... +125°C optional
|
INDUcoder
Robust Encoder AWG 102 / EAS 57
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 100 mm
|
ø 10 mm
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
|
-40 ... +125°C optional
|
INDUcoder
Euro Absolut No Shaft Encoder CAH 36 S / CAH 36 M
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Magnetic absolute
|
ø 36 mm
|
ø 6 mm
|
8192 = 13 bit
4096 = 12 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 54
|
-
|
|
-30 ... +70°C
|
INDUcoder
Absolut No Shaft Encoder CAH 57 S / CAH 57 M SSI
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 15 mm
|
65536 = 16 bit
8192 = 13 bit
4096 = 12 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-40 ... +85°C
|
INDUcoder
Absolut No Shaft Encoder CAH 58 Parallel
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 15 mm
|
65536 = 16 bit
8192 = 13 bit
4096 = 12 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-40 ... +85°C
|
INDUcoder
Absolut No Shaft Encoder CAH 58 Profibus / CANopen® / Device Net
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 15 mm
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-40 ... +85°C
|
INDUcoder
Niro Absolut No Shaft Encoder NAH 58 Profibus / CANopen® / Device Net
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 15 mm
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
ø 58 mm
|
|
-40 ... +85°C
|
INDUcoder
Absolut No Shaft Encoder CAH 58 Ethernet Powerlink
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 15 mm
|
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-0 ... +60°C
|
INDUcoder
Absolut No Shaft Encoder CAH 58 Interbus
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
ø 15 mm
|
4096 = 12 bit
8192 = 13 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 65
|
-
|
|
-0 ... +60°C
|
Incremental encoder
We produce incremental encoders as shaft and as hollow shaft encoders with blind hollow shaft or hollow through shaft.
Our Micro encoder and Mini encoder have a size of 12 mm to 28 mm with a resolution of 1 up to 2,500 pulses per revolution, at 4x edge evaluation are 10,000 counting edges for jointing. As the output driver, we have push-pull outputs, RS422 line driver and open collector. Permissible speeds in this product area reach to 10,000 rev / min. Shaft diameter as a solid shaft range from 1.5 mm to 6.35 mm and a hollow shaft from 4 mm to 6 mm. PCB mount, plug and cable outlet is possible. Operating temperatures from -10 ° C to 85 ° C.
Our Euro encoders are shaft and blind hollow shaft encoder and are in the range of sizes from 35 mm to 40 mm with resolutions of up to 3600 pulses per revolution.
Our product group Standard encoder starts with the size from 58 mm and ends at 120 mm. Resolution per revolution are possible with the line number 1 to 900000, up to 18,000 signal periods per revolution with Sinus-/Cosinussignalen . Can be used at temperatures ranging from -42 ° C to +110 ° C. Permissible speeds in this range go up to 12,000 rev / min. Shaft diameters are available as a solid shaft of 6 mm to 12 mm and a hollow shaft of 6 mm to 55 mm, inch mounting dimensions are also available. Protection are available from IP 00 to IP 68. Supply voltage 5-30 volts output driver RS422 Line Drive , push-pull or 1 Vpp Sinus-/Cosinus
INDUcoder
Incremental Encoder
INDUcoder
Micro Encoder ES 12
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 12 mm
|
ø 2 mm
|
50, 60, 90, 100, 125
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 12 mm
|
1, 2
|
0 ... +50°C
|
INDUcoder
Micro Encoder ES 18
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 18 mm
|
-
|
100, 200, 250, 256, 300, 360
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 18 mm
|
2, 3
|
0 ... +50°C
|
INDUcoder
Micro Encoder ES 181
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 18 mm
|
ø 2.5 mm
|
100, 160, 200, 300, 360, 400, 500, 800, 1000, 1024, 1600
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 18 mm
|
3, 6
|
-10 ... +70°C
|
INDUcoder
Mini Encoder ES 24
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 24 mm
|
ø 4 mm
|
100, 300, 360, 500
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 24 mm
|
3
|
-10 ... +70°C
|
INDUcoder
Mini Encoder ED 26
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 26 mm
|
ø 4 mm
|
1 - 2500
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 54
|
ø 26 mm
|
3, 6
|
0 ... +80°C
|
INDUcoder
Mini Encoder ES 28
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 28 mm
|
ø 5 mm
|
36, 50, 60, 100, 150, 200, 250, 300, 360, 400, 500, 512, 600, 800, 1000, 1024, 1500
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 28 mm
|
3, 6
|
-10 ... +70°C
|
INDUcoder
Euro Encoder ED 35
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 35 mm
|
ø 6 mm
|
1 - 512
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 54, IP 65
|
ø 35 mm
|
2, 4
|
0 ... +80°C
|
INDUcoder
Euro Encoder ED 36
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 35 mm
|
ø 4 mm
|
1 - 3600
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65
|
ø 36 mm
|
3, 6
|
0 ... +80°C
|
INDUcoder
Euro Encoder ES 381
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 38 mm
|
ø 6 mm
|
20, 30, 32, 40, 50, 60, 100, 125, 200, 256, 300, 360, 400, 500, 512, 600, 800, 900, 1000, 1024, 1200, 1500, 1800, 2000, 2048, 2500, 3600
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 38 mm
|
3, 6
|
-10 ... +70°C
|
INDUcoder
Euro Encoder ES 382
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 38 mm
|
ø 6 mm
|
20, 30, 32, 40, 50, 60, 100, 125, 200, 256, 300, 360, 400, 500, 512, 600, 800, 900, 1000, 1024, 1200, 1500, 1800, 2000, 2048, 2500, 3600
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 38 mm
|
3, 6
|
-10 ... +70°C
|
INDUcoder
Euro Encoder ES 38
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 38 mm
|
ø 6 mm
|
30, 100, 200, 250, 256, 300, 360, 400, 500, 512, 600, 646, 800, 900, 1000, 1024, 1200, 1500, 1800, 2000, 2048, 2500
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 38 mm
|
3, 6
|
-10 ... +70°C
|
INDUcoder
Standard Encoder ED 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 6 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EEZ 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 6 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 63 EE 71
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 63 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EEL 58/90
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 90 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 107
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 7 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 107 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 110
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 90 mm
|
ø 10 mm
|
up to 900.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 110 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 115
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 7 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 115 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Robust Encoder AWG 101 / ED 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 100 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
3, 6
|
-40 .. +200°C optional
|
INDUcoder
Robust Encoder AWG 102 / EDH 581
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 100 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
3, 6
|
-40 .. +125°C optional
|
INDUcoder
Mini No Shaft Encoder EDH 26
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 26 mm
|
ø 6 mm
|
1 - 2500
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 54
|
ø 26 mm
|
3, 6
|
0 ... +80°C
|
INDUcoder
Euro No Shaft Encoder ES 401
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 38 mm
|
ø 5 mm
|
20, 30, 32, 40, 50, 60, 100, 125, 200, 256, 300, 360, 400, 500, 512, 600, 800, 900, 1000, 1024, 1200, 1500, 1800, 2000, 2048, 2500, 3600
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 38 mm
|
3, 6
|
-10 ... +70°C
|
INDUcoder
Standard No Shaft Encoder EDH 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 12 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 67
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 581
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 12 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 67
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 75/EDH 751
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 75 mm
|
ø 15 mm
|
up to 900.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 54, IP 65
|
ø 75 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 76/EDH 761
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 76 mm
|
ø 27 mm
|
up to 900.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 00, IP 54, IP 65
|
ø 76 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 110
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 90 mm
|
ø 27 mm
|
up to 900.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 00, IP 64
|
ø 110 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 120
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 120 mm
|
ø 55 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 52
|
ø 120 mm
|
3, 6
|
-20 .. +110°C optional
|
High-resolution encoder
For high-precision angle measuring high-resolution angle-measuring systems are available, for example as a reference sensor in testing and measuringobjects or high-resolution printing facilities in semiconductor manufacturing. The angle measurement accuracy is up to ± 5 arc seconds. Other features include: cosinus signals up to 18,000 cycles per revolution signal, output signals of 1 Vpp or 11 μAss, square-wave signals up to 900,000 pulses perrevolution = 3,600,000 counting edges, outputs RS422 Line driver or Push -pull outputs.
The high-resolution encoders are manufactured as shaft and hollow-shaft rotary encoder with hollow shaft or hollow through shaft in sizes from 58 mm to120mm. Fractional mounting dimensions are also available.
Optionally we can deliver our high-resolution angle measuring systems with the corresponding measurement protocol.
INDUcoder
High Resolution Encoder
INDUcoder
Standard Encoder ED 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 6 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EEZ 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 6 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 63 EE 71
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 63 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EEL 58/90
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 90 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 107
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 7 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 107 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 110
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 90 mm
|
ø 10 mm
|
up to 900.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 110 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard Encoder EE 115
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 7 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 68
|
ø 115 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Robust Encoder AWG 101 / ED 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 100 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
3, 6
|
-40 .. +200°C optional
|
Marka |
Ürün |
Model |
Özellik |
Inducoder |
Robust Encoder |
AWG 102 / EDH 581 |
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
|
Optical incremental
|
ø 100 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
3, 6
|
-40 .. +125°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 12 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 67
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 581
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 58 mm
|
ø 12 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 67
|
ø 58 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 75/EDH 751
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 75 mm
|
ø 15 mm
|
up to 900.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 54, IP 65
|
ø 75 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 76/EDH 761
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 76 mm
|
ø 27 mm
|
up to 900.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 00, IP 54, IP 65
|
ø 76 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 110
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 90 mm
|
ø 27 mm
|
up to 900.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 00, IP 64
|
ø 110 mm
|
3, 6
|
-42 .. +110°C optional
|
INDUcoder
Standard No Shaft Encoder EDH 120
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 120 mm
|
ø 55 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 52
|
ø 120 mm
|
3, 6
|
-20 .. +110°C optional
|
Robust encoder
A special feature of our house is the ROBUST ENCODER SYSTEM AWG / AWS.
It has been specially developed for use in special environments, such as in heavy industry, steel mills, mines, cranes, in ship and lock building and in the chemical and food processing industries. All housing parts, flange, cap, tube, tubular housing with 5 mm wall thickness are made of stainless steel. The shaft load of up to 1,500 N. The installation dimensions of the system are compatible to the known encoders. Both extreme temperatures from -40 ° C to + 200 ° C and exposure to dirt, water, alkalis and acids are not a problem. The protection class is IP 67. Because of the wide variety of options and accessories, use in pretty much any area is possible especially food-grade customs.
In the AWG - housings can be both incremental encoder and absolute encoder with SSI interface and all fieldbus connections (CAN -BUS , PROFIBUS, ETHERNET Powerlink, INTERBUS) block. We manufacture the ROBUST ENCODER SYSTEM AWG as a redundant encoder system with double or triple donors , in the combination of digital and analog encoders.
The area of application for the ROBUST ENCODER AWG 102 with through hollow shaft is the transmission of the rotational movement to already mounted ROBUST ENCODER Systems, limit switch, cam switches, speedometers or other devices that receive rotary motion.
Do not be afraid to talk to us if you do not find your desired encoder, inform our technicians will gladly advise you .
INDUcoder
Robust Encoder
INDUcoder
Robust Encoder AWG 101 / ED 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 100 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
3, 6
|
-40 .. +200°C optional
|
INDUcoder
Robust Encoder AWG 102 / EDH 581
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 100 mm
|
ø 10 mm
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
3, 6
|
-40 .. +125°C optional
|
INDUcoder
Robust Inkremental Weggeber AWS 101
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 100 mm
|
-
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67, IP 40
|
-
|
3, 6
|
0 ... +80°C
|
INDUcoder
Robust Encoder AWG 101 / EAM 58 Profibus / Canbus
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 100 mm
|
ø 10 mm
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
|
-40 ... +125°C optional
|
INDUcoder
Robust Encoder AWG 102 / EAS 57
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 100 mm
|
ø 10 mm
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67
|
ø 100 mm
|
|
-40 ... +125°C optional
|
INDUcoder
Robust Absolut Weggeber AWS 101
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 100 mm
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67, IP 40
|
-
|
|
0 ... +85°C
|
For the linear path and length measurement of our robust and compact Linear Motion incremental and absolute position encoder with
measurement length from Transducer 1 m up to 50 m.
Available with all common fieldbus interfaces
INDUcoder
Linear Motion Transducer
INDUcoder
Mini Weggeber WES 428
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 44 mm
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65
|
-
|
3, 6
|
-10 ... +70°C
|
INDUcoder
Inkrementaler Weggeber PLE 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 40
|
-
|
3, 6
|
0 ... +70°C
|
INDUcoder
Inkrementaler Weggeber PLE 85 / PLE 115
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 40
|
-
|
3, 6
|
0 ... +80°C
|
INDUcoder
Inkrementaler Weggeber PCE 180
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 40, IP 65
|
-
|
3, 6
|
0 ... +80°C
|
INDUcoder
Inkrementaler Weggeber PLE 200
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 40
|
-
|
3, 6
|
0 ... +80°C
|
INDUcoder
Robust Inkremental Weggeber AWS 101
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 100 mm
|
-
|
up to 500.000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67, IP 40
|
-
|
3, 6
|
0 ... +80°C
|
INDUcoder
Absolut Weggeber PLA 58
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 40
|
-
|
|
0 ... +70°C
|
INDUcoder
Absolut Weggeber PLA 85 / PLA 115
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 40
|
-
|
|
0 ... +70°C
|
INDUcoder
Absolut Weggeber PCA 180
Request offer
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50, IP 65
|
-
|
|
0 ... +70°C
|
INDUcoder
Absolut Weggeber PLA 200
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 40
|
-
|
|
0 ... +70°C
|
INDUcoder
Robust Absolut Weggeber AWS 101
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 100 mm
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 67, IP 40
|
-
|
|
0 ... +85°C
|
Manual Encoder
In this product range, we offer our Manual Encoder, which have incremental as well as absolute signals output and Programmable Terminals for setpoint for controllers.
The manual encoder have a resolution up to 10,000 pulses per revolution incremental, Bit/30 16 bit absolute and are equipped with a mechanical or magnetic latching mechanism. All fieldbus interfaces are available as connection option.
Incremental manual puls generator are the manual encoder of the product group ESV, ESO, ESM , with a mechanical detent and resolutions of 25 or 100 pulses per revolution with a supply voltage of 5 VDC or 12 VDC. There are very flat design from an installation depth of 9.7 mm and small sizes with a diameter of 60 mm.
The robust manual encoder with magnetic detent and detent 100 points based on our extremely reliable incremental and absolute encoders from our standard range, are unique.
The manual encoder with the standard incremental encoders with a resolution of 1 to 10,000 pulses per revolution and can be manufactured with any number of increments. It can be connected directly via the push-pull outputs or RS422 line driver outputs to the PLC. For the electrical connection terminal block, connector or cable outlet are available. The supply voltage is 5 VDC or 10-30 VDC. For the robust support of the shaft 2 large ball bearings are fitted into the flange. The shaft may also be optionally operated by a large handle. The front panel protection IP 65, is remarkable for handwheels .
The manual encoder with the standard absolute encoders provides the user with all standard interfaces, such as SSI, Profibus, CANopen, DeviceNet, Interbus, Ethernet Powerlink, parallel push-pull with a resolution of 16 bit Bit/30 available. The manual encoder are equipped with an electronic adjustment, change of direction, wear-free magnetic detent and are programmable and can be easily insert into existing systems by the connection to PLC / Fieldbus systems.
The incremental operating terminals EHP have a flat design of 31 mm made of ABS plastic and are protected by IP 65 suitable for use in harsh environments. The operator terminals that are programmable, up to 16 axes and four factors selected and the axis positions can be displayed. The devices have a switch for the axis " X , Y, Z , 4" , and a switch for the factor setting "1 , x10 , x100 " . The knob used with mechanical detent is available in the resolution of 25 or 100 pulses per revolution. The supply voltage is 5 VDC with RS422 line driver or 5-12 VDC with open-collector output with internal pull -up resistor . The data exchange takes place via an RS232 interface . Green LED indicator light, additional emergency stop button and partially 3-stage release button are possible. Fixing is by terminals or with a spiral cable of 2 , 3 or 5 meters in length.
INDUcoder
Manual Encoder
INDUcoder
Manual Encoder MEE 70
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 38 mm
|
-
|
20, 30, 32, 40, 50, 60, 100, 125, 200, 256, 300, 360, 400, 500, 512, 600, 800, 900, 1000, 1024, 1200, 1500, 1800, 2000, 2048, 2500, 3600
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 50
|
ø 60 mm
|
3, 6
|
-10 ... +70°C
|
INDUcoder
Manual Encoder EEM 70
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 62 mm
|
-
|
1 - 6000, 7000, 7200, 7500, 8000, 8192, 9000, 9144, 10000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 50
|
ø 62 mm
|
2, 4
|
-0 ... +80°C
|
INDUcoder
Manual Encoder EEV 70
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 57 mm
|
-
|
1 - 6000, 7000, 7200, 7500, 8000, 8192, 9000, 9144, 10000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65
|
ø 65 mm
|
3, 6
|
-0 ... +80°C
|
INDUcoder
Manual Encoder EEV 80
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
|
ø 57 mm
|
-
|
1 - 6000, 7000, 7200, 7500, 8000, 8192, 9000, 9144, 10000
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65
|
ø 65 mm
|
3, 6
|
-0 ... +80°C
|
INDUcoder
Manual Encoder ESO 60
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 60 mm
|
-
|
25, 100
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
|
ø 60 mm
|
2, 4
|
-10° ... 60°C
|
INDUcoder
Manual Encoder ESO 77
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 80 mm
|
-
|
25, 100
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
|
ø 80 mm
|
2, 4
|
-10 ... +60°C
|
INDUcoder
Manual Encoder ESV 60
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 60 mm
|
-
|
25, 100
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
|
ø 60 mm
|
2, 4
|
-10 ... +60°C
|
INDUcoder
Manual Encoder ESM 80
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
ø 60 mm
|
-
|
100
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
|
ø 80 mm
|
2, 4
|
-10 ... +60°C
|
INDUcoder
Handy Pulser EHP-L/LO
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical incremental
|
-
|
-
|
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65
|
-
|
2, 4
|
-10 ... +60°C
|
INDUcoder
Absolut Manual Encoder MEA 70 Ethernet Powerlink
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
-
|
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-0 ... +60°C
|
INDUcoder
Absolut Manual Encoder MEA 70 Profibus / CANopen® / Device Net
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
-
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-40 ... +85°C
|
INDUcoder
Absolut Manual Encoder MEA 70 SSI
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
-
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-40 ... +85°C
|
INDUcoder
Absolut Manual Encoder MEA 70 Parallel
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
-
|
4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-30 ... +70°C
|
INDUcoder
Absolut Manual Encoder MEA 70 Interbus
Method
|
Case diameter
|
Shaft diameter
|
Resolution
|
Optical absolute
|
ø 58 mm
|
-
|
4096 = 12 bit
8192 = 13 bit
|
Protection class
|
Flange diameter
|
Channels
|
Temperature range
|
IP 65, IP 66
|
-
|
|
-0 ... +60°C
|
Display Modules
Multifunctional display modules for the connection of one or two incremental or absolute encoders. Red glowing 8-digit, 7-segment LED display with 14 mmhigh digits. Up to 8 programmable control inputs and up to 16 programmable switching outputs, 1 programmable analog output with up to 16-bit resolutioncan be operated as a voltage output -10 .. +10 V or current output -20 .. +20 mA. Parallel interfaces for data entry and transfer of data to a PLC or large display. All inputs and outputs are brought out via optocouplers.
RS232, RS422/RS485 interfaces and CANBUS for connecting a display module to a PC or to interconnect up to 32 display modules on a bus. Housing forpanel mounting with rear pluggable terminal strips. All display modules are also available as a desktop unit in a rugged aluminum housing for use in workshops and on measuring stations
Display Modules
INDUcoder
Multifunctional Display Module MOD 21
Multifunctional display module for the simultaneous connection of two incremental and / or absolute encoders. Red glowing 8- digit, 7- segment LED display with 14 mm high digits. 2 SSI interface for absolute encoders and signal inputs for 2 incremental encoders with 3 or 6 channels. The scale factor, the decimal point and the zero point are fully programmable. 8 programmable control inputs and 16 programmable outputs. 1 programmable analog output with 16 -bit resolution can be operated as a voltage output -10 .. +10 V or current output -20 .. +20 mA. All inputs and outputs are led out via optocouplers. RS232, RS422/RS485 interfaces and CANBUS for connecting a display module to a PC or to interconnect up to 32 display modules on a bus. The supply voltage is 10..30 VDC. The housing is provided for panel mounting and electrical connection is made available via a rear pluggable terminal strip.
INDUcoder
Multifunctional Display Module MOD 20
Multifunctional display module for the connection of an incremental or absolute encoder. Red glowing 8- digit, 7- segment LED display with 14 mm high digits. SSI interface for absolute encoders and a signal inputs for incremental encoder with 3 or 6 channels. The scale factor, the decimal point and the zero point are fully programmable. 6 programmable control inputs and 9 programmable switching outputs. 1 programmable analog output with 16 -bit resolution can be operated as a voltage output -10 .. +10 V or current output -20 .. +20 mA. A parallel input for data entry in Gray, binary or BCD code and a parallel output for data output in Gray code, binary or BCD code. All inputs and outputs are led out via optocouplers.
RS232, RS422/RS485 interfaces and CANBUS for connecting a display module to a PC or to interconnect up to 32 display modules on a bus. The supply voltage is 10..30 VDC. The housing is provided for panel mounting and electrical connection is made available via a rear pluggable terminal strip.
INDUcoder
SSI Display Module MOD 14
Display module for connecting an absolute encoder with SSI interface. Red glowing 8- digit, 7- segment LED display with 14 mm high digits. The scale factor, the decimal point and the zero point are fully programmable. A programmable control input and a control input to store the display value. Four switching outputs that can be programmed as a threshold switch, cam switch or pulse switch. The switching thresholds and hysteresis are adjustable. An analog voltage output -10 .. +10 V and an analog current output -20 .. +20 mA. The resolution of the D / A converter is 14 bits. Over a 24-bit parallel input setpoints can be entered for the switch outputs in Gray, binary or BCD code. Over a 24-bit parallel output of the display value in gray, binary or BCD code can be output. All inputs and outputs are led out via optocouplers. An RS485 interface allows reading the position data and the status of all inputs and outputs. In addition, all parameters can be set. The supply voltage is 10..30 VDC. The housing is provided for panel mounting and electrical connection is made available via a rear pluggable terminal strip.
INDUcoder
Incremental Display Module MOD 13
Display module for connecting an incremental encoder. Red glowing 8-digit, 7-segment LED display with 14 mm high digits. Encoders can be connected with 3 or 6 channels with push-pull outputs or RS422 Line Driver. The scale factor, the decimal point and the zero point are fully programmable. A programmable control input and a control input to store the display value. Two switching outputs that can be programmed as a threshold switch, cam switch or pulse switch. The switching thresholds and hysteresis are adjustable. The inputs and outputs are led out via optocouplers. The supply voltage is 10 .. 30 VDC. The housing is provided for panel mounting and electrical connection is made available via a ru¨ckseitige pluggable terminal strip.
For the safe use of our encoder we offer different mounting aids, such as torque arms, servo clamps, measuring wheels, shaft couplings, flange adapters -even squares - mounting bells and brackets on. Besides, we also provide the required connectors and cable assemblies for the electrical connection of ourencoder.
INDUcoder
Shaft coupling ASK
INDUcoder
Flexible spring mountings
INDUcoder
Connector Harting
INDUcoder
Adapter flanges
INDUcoder
Mounting Bracket
INDUcoder
Mounting Bell MG58
INDUcoder
Measuring Wheel 200 mm smooth MR200PG
INDUcoder
Measuring Wheel 200 mm knurled MR200PR
INDUcoder
Measuring Wheel 200 mm burled MR200PN
INDUcoder
Measuring Wheel 200 mm knurled aluminium MR200AK
INDUcoder
Measuring Wheel 500 mm smooth MR500PG
INDUcoder
Measuring Wheel 500 mm knurled MR500PR
INDUcoder
Measuring Wheel 500 mm burled MR500PN
INDUcoder
Measuring Wheel 500 mm knurled aluminium MR500AK