Migatron Products
Self Contained Sensors
Self contained sensors are devices where the sensor and the controller are built into the same unit.
Migatron
|
RPS-150
Ranges: 2-40", 5-80"
Broad beam
On/off output with analog capability
|
Migatron
|
RPS-150A
Ranges: 2-40", 5-80"
Broad beam
Analog output
|
Migatron
|
RPS-400-6
Range: 2-6"
Narrow Beam
Three wire NPN transistor output
|
Migatron
|
RPS-400-30 Sensor
Self Contained
Sensing Range 5-30"
Narrow Sensing Beam
|
Migatron
|
RPS-401,426
Ranges: 4-40", 8-80"
Narrow beam
On/off output
|
Migatron
|
RPS-401A,426A
Ranges: 4-40", 8-80"
Narrow beam
Analog output
|
Migatron
|
RPS-401A-80P
Ranges: 8-80"
Narrow beam
Analog output
|
Migatron
|
RPS-409A
Ranges: 4-40", 6-80" and 10-144"
Analog output
Temperature compensation
Sync/enable option
|
Migatron
|
RPS-409A-IS
Ranges: 4-40", 6-80", 12-144", 12-216"
Analog output
Intrinsically Safe Design
UL Listed
|
Migatron
|
RPS-412A
High accuracy analog ultrasonic sensor (±0.002" or 0.05% of range, which ever is greater, at 25°C).
|
Migatron
|
RPS-450,475
Ranges: 5-30", 10-72"
Proximity sensor
|
Migatron
|
TBT/TBR-600
Range: 0-40"
Thru beam
On/off output
Adjustable. count rate
|
Migatron
|
RPS-3000/4000
Range 2-40 feet
Analog output
Temperature compensation
|
RPS-412A
HIGH ACCURACY SENSOR
Features
|
|
Migatron
The RPS-412A is a high accuracy analog ultrasonic sensor (±0.002" or 0.05% of range, which ever is greater, at 25°C). The sensor has a built in temperature compensation target, that monitors and compensates for air temperature 50 times per second. The sensor also compensates for changes in relative humidity, changes in barometric pressure, and other factors that influence the speed of sound.
The RPS-412A has a 47mm stainless steel barrel housing. The stainless steel housing is electrically isolated from the sensor electronics. The sensor comes with two jam nuts for mounting.
The RPS-412A has a 0-10V analog output. The analog output is fixed. The RPS-412A-16 is 0.625V per inch. The RPS-412A-10 is 1.000V per inch. For example using the 3-16" range version, a target placed 3 inches from the sensor face will result in a sensor output of 1.875V. A target placed 16 inches from the sensor face will result in a sensor output of 10.0V.
The RPS-412A is designed to take advantage of today's PLC and computer analog input cards. The analog input card will determine the resolution of the system. The numerical values programmed into the PLC or computer will determine the zero and span
|
|
.
|
SPECIFICATIONS
Model: Range: Volts per Inch:
RPS-412A-10-V 3" -10" 1.000V
RPS-412A-16-V 3" -16" 0.625V
Accuracy: ±0.002², or ± 0.05% of range (which ever is greater) @ 25ºC.
±0.2% of range from 0 to 50ºC
Power Input: 20 to 30VDC Reverse Polarity Protected
Input Current: 65mA Typical
Operating Temperature: 0 to 50ºC
Output: Analog Voltage Output
Short Circuit Protected
Output Referenced to Power GND or Signal GND
Load 500 Ohms to Infinity
Frequency: 60kHz
|
|
|
Housing Material: Stainless Steel with PVC Head
Sample Rate: 20ms Typical
Update Time: 2s Maximum
Weight: 22 oz. (shipping weight 3 lbs.)
Figure:
A- Wiring Diagram
B- Back View of Sensor
C- Connector Diagram
D- Housing Diagram
|
|
|
PART NUMBER
|
RANGE OUTPUT
|
DESCRIPTION
|
RPS-412A-10-V
RPS-412A-16-V
|
3" to 10"
3" to 16"
|
0 - 10VDC Analog Output
0 - 10VDC Analog Output
|
F32-5070042
F32-5070053
F32-5070094
|
|
6' Snap-In Cable, Straight (sold separately)
6' Locking Cable, Straight (sold separately)
6' Locking Cable, Right-Angle (sold separately)
|
SENSOR SETUP
Air Temperature:
The air temperature between the sensor and target must be constant. Any variations in air temperature will compromise the accuracy. The sensor can compensate for changes in air temperature provided the air temperature is constant between the sensor and target. If the air temperature varies between the sensor and target (For example if the air temperature is 20°C from the sensor face to half way to the target, and the air temperature is 25°C for the remainder of the distance) the sensor cannot compensate for the temperature variation.
Sensor Alignment:
The sensor must be aligned to obtain the best accuracy. To align the sensor place the target you will be measuring at the farthest distance it will be from the sensor. Monitor the color of the LED on the sensor (green is no signal, light red is a weak signal, and bright red is a strong signal) align the sensor, so the LED is the brightest red color you can get. This will be the optimum alignment of the sensor.
Calibration:
The sensor comes pre calibrated from the factory. The sensor may be recalibrated in the field.
Follow the steps below to recalibrate.
1. Sensor alignment must be done before calibration.
2. P1 must be adjusted first.
3. Place the target at the near distance (closest distance target will get to sensor). Measure the distance from the target to the transducer face (DO NOT TOUCH THE FACE OF THE TRANSDUCER).
4. Calculate the voltage for the near distance. Multiply the distance by the volts per inch. Adjust P1 for the calculated voltage.
5. Place the target at the far distance (farthest distance target will be from sensor). Measure the distance from the target to the transducer face.
6. Calculate the voltage for the far distance. Multiply the distance by the volts per inch. Adjust P2 for the calculated voltage.
7. Repeat the adjustment of P1 and P2 to check for accuracy.
|
Close Range Sensors
Detect objects within 2 to 6 inches of the sensor.
Migatron
RPS-400-30 Sensor
Self Contained Sensor
Sensing Range 5-30"
Narrow Sensing Beam
|
|
Migatron
|
RPS-400-6
Range: 2-6"
Narrow Beam Sensor
Three wire NPN transistor output
|
Migatron
|
RPS-100
Ranges: 2-14", 5-72", 10-240"
Broad Beam Sensor
On/Off Output with analog capability
|
Migatron
|
RPS-102
Ranges: 2-14", 5-72", 10-240"
Broad Beam Sensor
On/Off Output
|
Migatron
|
RPS-150
Ranges: 2-40", 5-80"
Broad Beam Sensor
On/Off Output
|
Migatron
|
RPS-150A
Ranges: 2-40", 5-80"
Broad Beam Sensor
0 - 10VDC and 4 - 20 mA Analog Output
|
Migatron
|
RPS-2100
Ranges: 2-14", 5-72", 10-240"
Broad Beam Sensor
On/Off Output
|
Intrinsically Safe and Explosion Proof Sensors
Ultrasonic sensors for use in environments classified as hazardous.
Migatron
|
RPS-409A-IS
Ranges: 4-40", 6-80", 12-144", 12-216"
Narrow Beam
0 - 10 VDC Analog Output
|
Migatron
|
RPS-326-X
Ranges: 24-72", 24-240"
Narrow Beam
On/Off Output with analog capability
|
Controllers With Remote Sensing Heads
These are devices where the sensor and the controller are separate units and can be located in separate locations.
Migatron
|
RPS-100
Ranges: 2-14", 5-72", 10-240"
Broad beam sensor
On/off output with analog capability
|
Migatron
|
RPS-102
Ranges: 2-14", 5-72", 10-240"
Broad beam sensor
On/off output, dual transducers
|
Migatron
|
RPS-300
Ranges: 4-14", 5-36", 8-72"
Narrow beam sensor
on/off output with analog capability
|
Migatron
|
RPS-300T Teflon ®
Ranges: 4-14", 5-36"
Narrow beam sensor
On/off output with analog capability
|
Migatron
|
RPS-302
Ranges: 4-14", 5-36", 8-72"
Narrow beam sensor
On/off output
|
Migatron
|
RPS-322
Range: 8-72"
Narrow beam sensor
Dual transducers, on/off output
|
Migatron
|
RPS-325
Range: 8-72"
Narrow beam sensor
On/off output with analog capability, sealed transducer
|
Migatron
|
RPS-326
Range: 24-72", 24-240"
Narrow beam sensor
Explosion-proof
On/off output with analog capability
|
Migatron
|
RPS-500
Analog ranging card
Zero, span, sample, and hold controls
|
Migatron
|
RPS-2100
Ranges: 2-14", 5-72", 10-240"
Broad beam sensor
On/off output
|
Migatron
|
RPS-2300
Ranges: 4-14", 5-36", 8-72"
Narrow beam sensor
On/off output
|
Migatron
|
RPS-2325
Range: 8-72"
Narrow beam sensor
On/off output
steel transducer
|
Migatron
|
RPS-8000
Ranges: 4-12", 5-36", 8-72"
Multiplexed: 2-8 transducers
Narrow beams sensor
On/off output
|
Set Point Controllers
Migatron
|
M-1000
An analog controller with four individual set-points and temperature compensation.
|
Migatron
|
SPC-701
Set point controller One adjustable set point.
|
Migatron
|
SPC-704
Set Point Controller Four adjustable set points
|
Migatron Corporation markasına ait tüm ürünler