Since 1955, Nihon Klingage has been making magnetic level gages in Japan and providing to the world.
Our Magnetic Level Gauge provides safe, reliable and maintenance free solution to liquid level detection of toxic, corrosive, high pressure, high temperature
Nihon Klingage is a global specialist manufacturer of liquid level indicators for industrial use. Nihon Klingage has the largest share of the market in glass type liquid level indicators.
Nihon Klingage was the first company in Japan to develop and commercialize magnetic float type liquid level indicators. These indicators are used in petrochemical plants in various countries of the world.
Nihon Klingage manufactures glass type liquid level indicators (direct viewing), magnet float type liquid level gauges and sight glass.
Nihon Klingage Products cover a variety of uses, from high temperature and high pressure to extremely low temperatures and general purpose products, depending on the process
Direct Reading Liquid Level Gages
Nihon Klingage Direct Reading Liquid Level Gages Tubular Type
Tubular glass or resin forms a liquid chamber between upper and lower gage valves. It is the most simple and inexpensive liquid level gage which can be used under normal or relatively low pressures.
Tube can be marked with red lines to observe the liquid level easily. Resin(Fluorocarbon, Acrylic and PVC) tubes can be used for corrosive liquid.
Scale board, float (applicable for the liquid of specific gravity over 0.55) and jacket are available.
As for valve material, carbon steel, stainless steel (SUS304,SUS304L,SUS316,SUS316L) , resin (PP,PVC) and several lining are available.
Tne center to center lenght is avilable from 300 mm.
Standart Model : TUP-BA11A-21
Glass Tube Measuring Gage
Nihon Klingage Co.,Ltd. manufactures the liquid surface meter product which corresponded to all the needs in the design.
As for the measure ring gage to use for the measurement extraction of the measurement pouring, various liquids such as the catalyst and so on, too, it supplies the product which corresponded to the specification, the capacity, the installation length, the diameter, the material, the graduation, the equal needs of the request.
To the high-pressure one With KLINGAGE large chamber type Direct Reading Liquid Level Gage, the measure ring gage, and so on, corresponds.
Nihon Klingage Direct Reading Liquid Level Gages Reflex Type
Reflex Type
PRINCIPLE Prismatic serations of the whole visual area on the the liquid contact surface of reflex glass gives a prism effect. The reflex prisms are molded and polished to provide a crisp black silver bi-color indication of the fluid level. When light passes into reflex glass, if there is fluid present the light continues through the glass an impacts the back of the level gage, provided a black color for fluid level regardless of the actual color properties of the process fluid. If fluid is not present, the light is reflected back towards the user providing a shiny silver. Reflex types are not suitable for alkaline liquid because mica plate cannot be attached on the surface of prasmatic serations. *NIHON KLINGAGE has developed Alkline resistant glass named LUKING-AR refering to Glass Products page.
FEATURE
-
Less expensive than Transperent Type
-
Lower cost of maintenance than Transparent Type
-
Easier to obserev the level of clear liquid than Transperent Type
-
NIHON KLINGAGE is able to offer Reflex Type for the highest pressure and temperarture application in the world
-
For emergency, upper and lower Check Ball Valve are standardized
-
Various material choices : Carbon steel (S25C、A105), stainless steel (SUS304、SUS316、SUS304L、SUS316L), Titanium, Monel, Hastelloy and various resin linings
-
Various options : Ultraviolet cut plate, Light-shielding chamber, Thermal jacket, Non- frosting window for the low temperature and Large diameter chamber for high viscosity fluid and Scales
-
Various glass options : Teflon (PFA) Coated Glass – KLEARCOATR Glass, V-notched Color Glass ( Bi-KC glass )
-
Installation support is available.
-
NIHON KLINGAGE is ready to design Reflex Type Level Gages according to customer’s requirement
Reflex Liquid Level Gages Model R40
Zigzag Liquid Level Gages
Alternate arrangement of gages in double lines enables to observe continuous liquid level over the whole visible range.
These gages are used for such as storage tank of LPG.
Carbon steel (S25C、A105), stainless steel (SUS304、SUS316、SUS304L、SUS316L), Titanium, Monel, Hastelloy and various Resin linings are available.
KLINGAGE Zigzag Liquid Level Gages
RS40W-WA16B-21 type
Nihon Klingage Direct Reading Liquid Level Gages Transparent Type
Transparent Type
PRINCIPLE Flat tempered glass is mounted on each side of the liquid chamber and held between gage covers. Liquid level, boundary level and liquid color are observed by the differece of transmission of light emitted from the illuminator behind.
Features
-
Applicable for almost all liquid including Alkaline solution
-
Suitable to observe boundary suraface
-
Suitable to observe the color of the liquid
-
NIHON KLINGAGE is able to offer Reflex Type for the highest pressure and temperarture application in the world.
-
For emergency, upper and lower Check Ball Valve are standardized.
-
Various material choices : Carbon steel (S25C、A105), stainless steel (SUS304、SUS316、SUS304L、SUS316L), Titanium, Monel, Hastelloy and various resin linings
-
Various options : Ultraviolet cut plate, Light-shielding chamber, Thermal jacket, Non- frosting window for the low temperature liquid, Large diameter chamber for high viscosity fluid, illuminators ( Explosion-proof ) and Scales
-
Various glass options : Teflon (PFA) Coated Glass – KLEARCOATR Glass, V-notched Color Glass ( Bi-KC glass )
-
Installation support is available.
-
NIHON KLINGAGE is ready to design Transperent Type Level Gages according to customer’s requirement.
Transparent Liquid Level Gages
Model T30
Zigzag Liquid Level Gages
Alternate arrangement of gages in double lines enables to observe continuous liquid level over the whole visible range.
These gages are used for such as storage tank of LPG.
Carbon steel (S25C、A105), stainless steel (SUS304、SUS316、SUS304L、SUS316L), Titanium, Monel, Hastelloy and various Resin linings are available.
Zigzag Liquid Level Gages
Model RS40W-WA16B-21
Nihon Klingage Direct Reading Liquid Level Gages Weld on Type
Weld On Type is welded directly on the container. NIHON KLINGAGE offers highly safe product by means of original sealing technology. Reflex Types (RWB1-25、RWB1-32) and Transparent Weld On Types(TWB1-25、TWB1-32) and Round Types(CWB1 series ) are our standard types. . NIHON KLINGAGE is ready to design Weld On Type Level Gages according to customer’srequirement.
RWB1-25 #5×1
Standard type Weld On Type(RWB1-25,RWB1-32,TWB1-25,TWB1-32
Models
-
Reflex type RWB1-25
-
Reflex type RWB1-32
-
Transparent type TWB1-25
-
Transparent type TWB1-32
-
Circle type CWB1 series
Nihon Klingage Direct Reading Liquid Level Gages Check Ball Valves for Tubulra Types
Check Ball Valves for Tubular Level Gages are available to order.
dimensions
The Nihon Klingage Co.,Ltd. manufactures at the optional desire installation size under at all Liquid Level Gages.
KLINGAGE Tubular (glass) Manufacturing the standard installation length of Liquid Level Gage from a minimum of 300 mm The one which exceeds the longest installation length corresponds by the support.( The following reference )
It manufactures to the request about the Liquid Level Gages installation VESSEL shape and the standard. ( Standard installation VESSEL: 20A JIS 10 K The flange )
At the Visual Length, being under, it depends on the valve format.Refer to the following
NKG Check Ball Valve
(Carbon Steel・Stainless Steel)
Nihon Klingage Direct Reading Liquid Level Gages Drain Valves
Drain Valves
Drain valves for liquid level gages are chosen according to the working condition such as pressure, temperature and sort of fluid.
NIHON KLINGAGE provides various drain valves to satisfy that working condition.
Nihon Klingage Magnetic Type Level Gage
INTRODUCTION
Since 1955, NIHON KLINGAGE has been making magnetic level gages in Japan and providing to the world.
Our Magnetic Level Gauge provides safe, reliable and maintenance free solution to liquid level detection of toxic, corrosive, high pressure, high temperature
FEATURE
3 main conponents
1. Float chamber The chamber is made of non-magnetic material and is attached on vessel. A float is housed in the non-magnetic float chamber. The float will move up and down in the chamber as level rises or falls in the vessel on which it is attached.
2. Magnetic float Floats are individually designed and optimized for each application according to working condition.
3. External indicator The hermetically sealed indicator unit, which is mounted on the outside of the gage, contains a magnetic indicator that interlocks magnetically with the float inside the chamber. As the float moves up and down with the liquid level, the magnetic indicator element tracks the changes in level.
Nihon Klingage Magnetic Type Level Gage
MGS100 Series(Standard Type)
MGS100 series are designed for high pressure and high temperlature application.
MGS100 Series (Standard Type)
Type MGS111R-11-21
Nihon Klingage Magnetic Type Level Gage
MGS400 Series(High Pressure Type)
MGS400 series are designed to be used under extreme high pressure.
The chamber wall is much thicker than MGS100.
MGS400 Series (High Pressure Type)
Type MGS414R-55-F2
Nihon Klingage Magnetic Type Level Gage
MGE100 Series(Non-Frost Type)
MGE100 Series(Anti freeze type)
MGE100 series are designed for low temperature fluid applications. Antifreeze indicator is standardized in MGE100 series.
MGE100 Series (Non-Frost Type)
MGE111R1-11-221
Nihon Klingage Magnetic Type Level Gage
MGV Series for Ultra low temperature
MGV series (Ultra low temperature type)
MGV series are designed for ultra low temperature fluid aplications. Vacuum insulation technology is applied.
Nihon Klingage Magnetic Type Level Gage
MGB100 Series fior low-boiling point fluid
In the open air, the level of low boil point fluid such as LPG flucuates rapidly with float and the indicator become not to follow the change of the level.
The unique double tube structure of MGB100 series are able to minimize the rapid fluctuation of fluid level and enable to see the level
MGB for LPG
MGB122R-31-21
Nihon Klingage Magnetic Type Level Gage
MGS Series for boiler
Boiler Type (MGD)
Magnetic Level Gage provides one of the safest and most economical solutions to measure and control level measurement needs.
NIHON KLIMGAGE offers highly safe products for high pressure and high temperature boiler application.
FEATURE
-
The unique device which is able to adhere iron filings in boiler water is installed in our Magnetic Level Gage.
-
That akes float move smoothly and enable stable level measurement.
Notes
-
Iron particle removal device( PAT NO.2818753 )
-
Iron particles in boiler water adhere on the magnetic float and it causes the float become stuck in the chamber. The device traps iron particles to prevent the float get stucked.
Nihon Klingage Magnetic Type Level Gage
MGJ100 Series(Jacketed Type)
Jacket Type (MGJ100 Series)
MGJ 100 series has Termal jacket to keep the liquid temperature stable. It enables to measure the level of high coagulating point or low boiling point liquid.
MGJ100 Series (Jacketed Type) MGJ112R-11-21
Nihon Klingage Magnetic Type Level Gage
MGN100 Series(Lining Type)
NKG MGN100 series are designed for corrosive liquid measurement. The body is lined with suitable material against various corrosive chemicals.
MGN100 Series (Lining Type)
MGN141R-11 (Glass lining )
Nihon Klingage Magnetic Type Level Gage
MS Reed Switches
MS Reed switch is a latching switch designed for magenetic level gages. It is easily installed on the chamber for point level control and alarm. Standard type MS-11 and explosion proof (ExdⅡCT6) type RSW-EX-1 are available.
MS Reed Switch installed on MGB
Models :
MS-11
RSW-EX-1
Nihon Klingage Magnetic Level Gages
Level Detectors
FEATURE
Level Detector is attached together with indicator on the colum of magnetic level gage to measure liquid level.It converts the liquid level into DC4~20mA digital signal which enables to monitor and control the level gage from different place.
The combination with level monitoring system(NR-3000B) enables to check liquid volume and weight. Alarming is possible.
Magnetostrictive Liquid-Level Sensors are also available.
PRINCIPLE
Number of magnetic assemblies are installed at the same intervals manner according to the range of level monitoring. The movement of the float switches the magnetic assemblies so that voltage output is proportional to the liquid level.
The ouput is converted DC4~20mA signal by R/1 converter.
Type MGB (Double tube type)
MGB122R-31-21 Gage with Level Detector
Nihon Klingage Magnetic Level Gages
Level Monitoring System NR-3000B
Level Monitoring System NR-3000B in combination with Level Detector on Magnetic Level Gage enables various kinds of liquid level monitoring.
Level Monitoring System Model NR-1000
Nihon Klingage Magnetic Level Gages
Magnetic Float
Float
NIHON KLINGAGE magnetic floats are individually engineered for each applicationis. It is applicable to monitor the level of the boundary surface between fluids.
We design the float length as short as possible and it enables to minimize the effect to the fluid level from emvironment
SUS316 Type
Sealing up type Float ( Type LP1 )
Nihon Klingage Magnetic Level Gages
Indicator for Magnetic Level Gage
Indicator
A magnetic, highly visible bar graph indicator, encapsulated in a hermetically sealed unit, is attached to the outside of the float chamber. It indicates the liquid or interface level without being in contact with the process fluid. Problems with colorless or dirty fluids are solved since the indicator is non-contact. It is also designed to apply high vaper pressure liquid.
NKG MG-R Rotor Indicator
Nihon Klingage Glass Products
Nihon Klingage Glass for Armered Gages
Glass products for Direct Reading Liquid Level Gauges
* Reflex Glass
The reflex prisms are molded and polished to provide a crisp black silver bi-color indication of the fluid level. As light passed into the reflex glass, if there is fluid present the light continues through the glass an impacts the back of the level gage, provided a black color for fluid level regardless of the actual color properties of the process fluid. If fluid is not present, the light is reflected back towards the user providing a shiny silver.
* Bi-color Reflex Glass
Reflex prism is colored in red (Other colors are available.) to get the clear vision of fluid level. If there is no fluid present, red color is provided.
* Transparent Glass
Flat tempered glass is mounted on each side of the liquid chamber and held between gage covers. Liquid level, boundary level and liquid color are observed by the differece of transmission of light emitted from the illuminator behind.
Nihon Klingage Glass Products
Nihon Klingage KLEARCOAT – Teflon(PFA)Coat Glass
KLEARCOAT Glass is the glass coated with Teflon® PFA film and is used for adoptable to glass gages and sight glasses. Benefits : Resistance to chemical reaction and corrosion Teflon® PFA film and our unique coating technology provides excelent resistance against chemical reaction and corrosion.
Clear vision
Teflon® PFA Less adhiesiveness of Teflon® and transperency kept by our unique coating technology provides clear vision of sticky liquid level.
Superior non-sticking property
The surface coated with TEFLON® PFA film repels water, oil and almost all sticky substances. If such a substance should stick to it, it can be easily washed off.
Resistance to high temperature
KLEARCOAT GLASS is applicable to the fluid at maximum 170℃.
Safety
Teflon&req; PFA coat prevents glass from breaking into pieces.
NIHON KLINGAGE provides vaious shape of KLEARCOAT glasses for Direct Reading Liquid Level Gage, Sight Glass and other applications.
Nihon Klingage Glass Products
Nihon Klingage LUKING-AR Alkalin Resistant Glass
LUKING-AR
Glass has excellent corrosion resistance in general but is attacked and dissolved in service by alkalain solution, resulting in thinning of the wall and premature failure or replacement. High alkalinity and high temperature increase the rate of attack.
LUKING-AR has excellent resistance to high alkalinity and high temperature which enables reflex type gage is adoptable to high pressure boiler aplications.
* Alkalin Resistance
LUKING-AR is 800 times stronger than alumino silicate glass and 1,750 times than borosilicate glass.
* Mechanical strength
Bending strength : 270N/mm2(27kgf/mm2).
* Temperature resistance
Maximum service temperature : 500℃.
Nihon Klingage Level Switches
Side-Mount Type (LS-B)
Top-Mount Type(LS-E)
Nihon Klingage KLINPORT-Sight Glass
What is KLINPORT?
KLINPORT invented by NIHON KLINGAGE is a sight glass that glass and metal got united and became to have excellent airtightness by fusion bonding. Because the heart expansion rate of glass is different from metal, the glass become extremely strong agaist phsical damage.
Features
It is best as the sight glass to use in the environment which the high-pressure condition is severe on in the marvelous strength. The equipment main unit, and the straight or it is possible to connect with the taper screw. Therefore, the installation and the removal are simple and the maintenance is easy. Glass and the Metallic Ring fusion directly and it secures safe seal-ability. It is safe because the fragment doesn’t scatter even if glass damages.
* No Leakage
No No sealing material between glass and metal
* Easy Maintenance
Easy installation and replacement
* Safety
* Strong against phsical impact and vabration.
* Glass do not become fragment and scatter even if got phiscal damag.
KLINPORTR – Metal-to-glass Sealed Glass Products
-
KLINEPORTR Cross Glass
-
Weld On Type KLINPORTR – Type KP-360, KP-363
-
Straight thread KLINPORTR – Type KPS
-
High pressure use KLINPORTR – Type KP308
-
Straight thread High pressure KLINPORTR – Type KPS-C
-
Boiler use KLINPORTR – Type KP-32, KP-34
-
Taper thread KLINPORTR – Type AX
-
Taper thread KLINPORTR – Type KPT
-
Taper thread High pressure KLINPORTR – Type KPT-C
-
JAPAN U.S. Patented. KLINPORTR – Type KPF
Types of KLINPORT
Features
|
Model
|
Adaptation
|
Call by name
|
Material
|
Standard type
|
Type KPT
|
Atmospheric pressure~2MPa
|
-1Q
-2
※1
|
Carbon steel and Stainless steel
|
Type KPS
|
Vacuum~2MPa
|
Type KPF
|
Vacuum~2MPa
|
-1Q
-2
-3
-4
※1
|
Type AX※2
|
Atmospheric pressure~2MPa
|
Type KPL
|
Vacuum~2MPa
|
High pressure type
|
Type KPT-C
|
~17.3MPa
|
-1Q
-2
-3
-4
※1
|
Type KPS-C
|
~6.9MPa
|
Ultra High pressure type
|
Type KP-308
|
~49MPa
|
φ45×xH
|
Stainless steel
|
Type KP-32
|
15.7MPa/345.7℃
|
φ45×17H
|
Fe-Ni-Co
|
High pressure and High tempreature type
|
Type KP-34
|
21.6MPa/.372.1℃
|
φ52×22H
|
※1:Nominal diameter -1Q(1-1/4”) / -2(2”) / -3(3”) / -4(4”)
※2:2 types are available. -1Q(1-1/4”) / -2(2”)
Nihon Klingage KLINPORT-Sight Glass Type AX-2
Type AX – Tapered screw type
Materials : S25C, SUS304, SUS316 are available.
Model code
|
a
|
b
|
c
|
d
|
e
|
AX-1Q
|
25
|
R1-1/4
|
6
|
2.5
|
19
|
AX-2
|
40
|
R-2
|
6
|
4
|
24
|
Nihon Klingage KLINPORT-Sight Glass Type KPS – Straight screw type
Standard model with external straight screw connection. Materials : S25C, SUS304, SUS316 are available
Model
|
a
|
b
|
c※
|
d
|
e
|
f
|
g
|
KPS-1Q
|
25
|
G1-1/4
|
46
|
31
|
19
|
38
|
3
|
KPS-2
|
40
|
G2
|
65
|
43
|
27
|
55
|
5
|
KPS-3(discontinued)
|
70
|
G3
|
95
|
50
|
27
|
84
|
5
|
KPS-4(discontinued)
|
90
|
G4
|
115
|
58
|
29
|
109
|
5
|
Nihon Klingage KLINPORT-Sight Glass Type KPT – Tapered screw type
Materials : S25C, SUS304, SUS316 are available.
Model
|
a
|
b
|
c※
|
d
|
e
|
f
|
KPT-1Q
|
25
|
R1-1/4
|
46
|
31
|
25
|
6
|
KPT-2
|
40
|
R2
|
65
|
43
|
33
|
10
|
Nihon Klingage KLINPORT-Sight Glass Type KPF
KLINGAGE KLINPORT(Metal-to-glass Seald)
JAPAN U.S. Patented. KLINPORT used by flange setting Type KPF
Type KPF is KLINPORT installed between Flanges. Materials : S25C, SUS304, SUS316 are available(Only SUS316 is available for KPF-4.).
Model
|
a
|
b
|
c
|
KPF-1Q
|
25
|
38
|
13
|
KPF-2
|
40
|
55
|
18
|
KPF-3
|
70
|
84
|
25
|
KPF-4
|
90
|
109
|
35
|
Nihon Klingage KLINPORT-Sight Glass Type KPS-C
Type KPS-C for high pressure application – Straight screw type
Standard model for high pressure application, which has external straight screw connection. Materials : S25C, SUS304, SUS316 are available(Only SUS316 is available for KPS-C4.).
Model
|
A
|
a
|
b
|
c※
|
d
|
e
|
f
|
g
|
service pressure
kgf/cm2
(MPa)
|
service temperature
℃
|
hydrostatic test
kgf/cm2
(MPa)
|
KPS-C1Q
|
25
|
21
|
G1-1/4
|
46
|
31
|
25
|
38
|
3
|
135
(13.2)
|
250
|
205
(20.1)
|
KPS-C2
|
40
|
36
|
G2
|
65
|
43
|
33
|
59.254
|
5
|
70
(6.8)
|
200
|
105
(10.2)
|
KPS-C3
|
70
|
66
|
G3
|
95
|
50
|
37
|
84
|
5
|
30
(2.94)
|
120
|
45
(4.41)
|
KPS-C4
|
90
|
86
|
G4
|
115
|
58
|
43
|
109
|
5
|
30
(2.94)
|
90
|
45
(4.41)
|
Nihon Klingage KLINPORT-Sight Glass Type KPT-C
Type KPT-C for high pressure application – Tapered screw type
Materials : S25C, SUS304, SUS316 are available(Only SUS316 is available for KPT-C4.).
Model
|
A
|
a
|
b
|
c※
|
d
|
e
|
f
|
service pressure
kgf/cm2
(MPa)
|
service temperature
℃
|
hydrostatic test
kgf/cm2
(MPa)
|
KPT-C1Q
|
25
|
21
|
R1-1/4
|
46
|
38
|
32
|
6
|
176
(17.2)
|
250
|
274
(26.9)
|
KPT-C2
|
40
|
36
|
R2
|
65
|
45
|
35
|
10
|
93
(9.12)
|
200
|
140
(13.7)
|
KPT-C3
|
70
|
66
|
R3
|
95
|
58
|
45
|
13
|
30
(2.94)
|
120
|
45
(4.41)
|
KPT-C4
|
90
|
86
|
R4
|
115
|
65
|
50
|
15
|
30
(2.94)
|
90
|
45
(4.41)
|
Nihon Klingage KLINPORT-Sight Glass Type KP308
Type KP308 for super high pressure application
KLINPORT KP-308 type is designed especially for super high pressure application of petrochemical and synthesis chemical industries. It has 500kgf/c㎡pressure-resistance and is applicable for multi-port liquid level gages.
Model No.
|
H mm
|
t mm
|
Pressure – resistance
MPa(kgf/cm2)
|
Hydrostatic test
MPa(kgf/cm2)
|
KP-308-2
|
20
|
15
|
29.4 (300)
|
58.8 (600)
|
KP-308-3
|
24
|
19
|
49.0 (500)
|
78.5 (800)
|
Liquid level gage for super high pressure application
Model No.
|
Rating
|
Standard Size
|
Model Name
|
5P
|
7P
|
9P
|
L
|
LV
|
L
|
LV
|
L
|
LV
|
T300K
|
29.4MPa
(300kgf/cm2)
|
580
|
340
|
740
|
500
|
900
|
660
|
KP-308-2
|
T500K
|
49.0MPa
(500kgf/cm2)
|
680
|
420
|
880
|
620
|
1080
|
820
|
KP-308-3
|
Nihon Klingage KLINPORT-Sight Glass Type KP-32、KP-34
Type KP-32, KP-34 for high pressure boiler
KP-30 series are designed for BN200 Series water level gages.
Specification of KP-32, KP-34
Model
|
Material
|
Max.pressure
resistance(MPa)
|
Temperature
resistance
|
Size
|
Applicable
level
gages
|
φD
|
φd
|
H
|
t
|
KP-32
|
Fe-Ni-Co
|
15.7(160)
|
345.7
Saturated
|
45
|
20
|
17
|
12
|
BN200E
BT200E
BN201E
BT201E
|
KP-34
|
Fe-Ni-Co
|
21.6(220)
|
372.1
Saturated
|
52
|
20
|
22
|
15
|
BN210K
BT210K
|
KLINPORT Type KP-32,34 are designed to have enough strength for usage on high pressure boiler level gages.
Nihon Klingage KLINPORT-Sight Glass Type KP‐360、KP-363
Type KP-360, KP-363 – Weld on type
NIHON KLINGAGE is capable of designing KLINPORT according to customers’ requirement.
Nihon Klingage KLINPORT Cross Glass
Cross Type Sight Glass
Cross type sight glass in which KLINPORT is installed is designed especially for high temperature and high pressure application. Since KLINPORT is sealed on the metallic part and the glass part doesn’t touch the body directly, safety and maintainability is dramatically improved. Metal gasket is adaptable to improve the airtightness under high temperature and high pressure condition. NIHON KLINGAGE is capable of designing sight glasses according to customers’ requirement.
KLINPORT external screw connection
Since Type AX、 Type KPT、Type KPT-C、have external screw connection to join pipe connections
Türkiyede Nihon Klingage ürünleri ile ilgili uygun rekabetçi fiyatları almak için müşteri temsilcimizle ( http://www.imajteknik.com.tr/bize-ulasin ) veya Fiyat teklifi formunu ( http://www.imajteknik.com.tr/online-iletisim-formu ) doldurarak mesaj bırakmanız halinde satış mühendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.