ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik was founded in 1945 in Dresden. The production of high-quality temperature sensors and meteorological instruments laid the foundation for the success of the company as a reputed manufacturer of high-end precision instruments.
Today Rössel-Messtechnik is the specialist for all areas of temperature measuring technology with electrical contact thermometers. The company develops, produces and sells thermocouples, resistance thermometers, transmitters, measuring resistors, protective armatures and protection tubes, digital display instruments, multipoint temperature indicators, simulators, calibrators and accessories – optimum solutions for every application.
Rössel manufactures miniature and industrial thermocouples, Pt100 (RTD) and transmitters. A complete range of connectors, thermocouples and signal cables, instrumentation and accessories
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Products
Rössel-Messtechnik manufactures thermocouples for highly special applications.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Thermocouples
Thermocouples
The accuracy of temperature measurement depends to a very large degree on the quality of the sensor used. ROESSEL thermocouples are produced and tested using latest equipment and processes, there by guaranteeing constantly high quality and reliability levels. The various designs and dimensions of the sensors are in each case optimally adapted to the specific process conditions.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples
Application Range :
Automotive R&D
Physical R&D
Installations with less Space
Mineral-Insulated Metal-Sheathed (MIMS) thermocouples were successfully introduced many years ago into temperature measurement technology.
The standard versions are mainly used in the range between -270 °C and +1200 °C. They combine the advantages of high flexibility and easy handling in an extremely wide temperature range. They are supplemented by high-temperature MIMS thermocouples for operating temperatures of 2000 °C and above.
Inconel 600 is mainly used as sheath material, a nickel-based alloy. This material can easily be welded and soldered, it possesses extremely good resistivity characteristics also at higher temperatures and is resistant against most ambient conditions.
The thermocouple is often the type K (NiCr-Ni) acc. to IEC 60 584-1. Widely in use are also types L resp. J (both Fe-CuNi) and in the higher temperature range the noble metal types S R and B, which are platinum/rhodium alloys. The thermocouple wires are embedded in a compact insulation of high-purity MgO and enclosed by a metal sheath of a nickel/chromium/iron alloy or of stainless steel. The compact insulation fixes the wires securely so that no damage can occur because of strong vibrations or high bending loads. Also short circuits between the wires or between wire and sheath are virtually impossible.
Mechanically resistant
Easily bendable
Numerous different designs for nearly all applications
Short response times
Highly resistant against vibrations
Wide temperature range from -270 °C to over +2000 °C
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires Type AL - MIMS TC with cable
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires Type AL-RT - MIMS TC with mounting plate
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires Type ALS - MIMS TC with cable and LEMO connector
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires Typ ALSTE - MIM TC with cable and connector
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires Type B - MIMS TC with head type B
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires Type S - MIMS TC with Lemo connector directly connected
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires Type STE - MIMS TC with thermocouple connector directly connected
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Mineral Insulated Metal Sheathed Thermocouples Type A - MIMS TC with open wires Type WMM - MIMS TC as measuring insert
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Straight thermocouples
Application Range :
Furnaces / Crematoria
Glass Industry
Steel Industry
In numerous branches of industry heat-treatment and combustion processes play a decisive role during production and in the quality of the final product. These applications have one thing in common: Due to the high temperatures thermocouples are almost always used. Besides the non-precious-metal containing ones, mainly types E, J or L, K and N, platinum thermocouples types S, R or B are increasingly being used. These must be protected against contaminating, corrosive and/or abrasive ambient influences. Various designs with different protection tube materials are available for these applications.
Rössel Straight Thermocouples Design AM
Thermocouple with metal protection tube and Head type A
Rössel Straight Thermocouples Design AMK
Thermocouple with metal protection tube, ceramic inner protection tube and Head type A
Rössel Straight Thermocouples Design AK
Thermocouple with metal extension pipe, ceramic protection tube and Head type Form A
Rössel Straight Thermocouples Design AKK
Thermocouple with metal extension pipe, ceramic protection tube and Head type Form A
Rössel Straight Thermocouples Design BM
Thermocouple with metal protection tube and Head type A
Rössel Straight Thermocouples Design BMK
Thermocouple with metal protection tube, ceramic inner protection tube and Head type B
Rössel Straight Thermocouples Design BK
Thermocouple with metal extension pipe, ceramic protection tube and Head type Form B
Rössel Straight Thermocouples Design BKK
Thermocouple with metal extension pipe, ceramic protection tube and Head type Form B
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik TC with Protective Armatures
Application Range :
Power plant Technologies
Refineries
Refrigerate- and Liquid Waste Technology
Thermocouples in Thermowells
For protection against chemical and mechanical stresses thermocouples are installed in protective fittings. The optimal design is optained from the respective application.
The thermowells are made of metallic heat-resistant materials. The thermocouples are available with different mounting types, be it for screwing, welding or plugging, with flange or other conection technology.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik High Temperature MIMS TC
Application Range :
Application range over 2000°C
Aerospace
Physical R&D
High Temperature Thermocouples
ROESSEL high temperature thermocouples are manufactured for temperatures up to 2000 °C.
To a large extent these thermocouples are used in aeronautics, research laboratories and in industry.
For the various areas of application suitable sheath materials, thermocouple combinations and insulation materials are available.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Profile Thermocouples
Application Range :
Semiconductor Industry
TUS – Measuring acc. AMS 2750 D and CQI9
Measuring of Temperature uniformity
Profile thermocouples are used to measure temperature sequences in ovens, conduits and ventilation ducts.
In this design several thermocouples of different lengths are mounted inside a protection tube and connected to each other by a connection cable - as the example shown in the photo. The thermocouples can be both insulated sheath thermometers as well as a combination of individual thermocouples.
The lengths are variable within a wide range and can be adapted to the requirements of the customer.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Special Types
Application Range :
Mineral insulated metal sheathed with diameters from 0,25 mm and 0,5 mm
Plug-in Sensor
Adhesive Thermocouples
Thermocouples - Special Types
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik manufactures thermocouples for highly special applications
-
Thermocouples with extremely short response times
-
Surface thermocouples in many varying designs
-
Thermocouples for measurements on pipe and tank surfaces
-
Multi-junction thermocouples to record temperature profiles
-
Safety temperature detectors with wear notification
-
Development of customer-specific sensors
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Resistance Thermometers
ROESSEL has many years of experience, state-of-the-art manufacturing plants combined with a comprehensive quality control system.
This assures the reliability and accuracy of ROESSEL sensors.
The ROESSEL subsidiary CENTROCAL – a consulting, testing and calibration center for temperature measurement – calibrates temperature sensors at highest accuracy and with state-of-the-art equipment.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Resistance Thermometers MIMS Thermocouples - Types
MIMS resistance thermometer are highly versatile due to their special design. They can be mounted in places where conventional temperature sensors cannot be employed.
They are used in the automobile industry, in power plants, refineries, smelting plants, in ship-building, chemical industries, on combustion engines, testing plants, turbines, in medicine, on forges and foundries, in missile-building, in vacuum plants, etc.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnikmanufactures a large variety of designs from 1.0 to 8 mm diameter.
The wide temperature range from -200 °C to +850 °C for the standard resistance thermometers provides them with a wide field of applications.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Resistance Thermometers MIMS Thermocouples Type WA - MIMS Resistance Thermometer
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Resistance Thermometers MIMS Thermocouples Type WL - With hard-wired cable
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-MesstechnikResistance Thermometers MIMS Thermocouples Type WLS - With hard-wired cable and jack
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Resistance Thermometers MIMS Thermocouples Type WS - With hard-wired jack
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Resistance Thermometers MIMS Thermocouples Type WB ( B - WMM ) - MIMS Thermometer with connection head form B
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Resistance Thermometers MIMS Thermocouples Type W* - RT - MIMS Thermometer with weld-on plate
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Resistance Thermometers MIMS Thermocouples Typ WMM - Mantelwiderstandsthermometer als Messeinsatz
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Transmitters
ROESSEL transmitters are manufactured with state-of-the-art components using SMD technology. They are extremely resistant and meet highest demands. They can withstand harshest ambient conditions, and can also be supplied with ATEX certification. Resistivity against radio frequency interference acc. to industrial NAMUR standards is met.
Programmable transmitters reduce the number of measuring ranges, like with analog transmitters, to only one design. Analog transmitters are supplied with potentiometer for calibration point of zero and span, alternatively without potentiometer for highest requirements.
Our transmitters are supplied in intrinsically safe design acc. ATEX in EEx ia / ib II c T6. The electromagnetic compatibillity is acc. standard of industry to EN 50081 and EN 50082.
ROESSEL transmitters are manufactured in different designs. Prefered is the mounting in the lid of the connection head or directly on the measuring insert. Designs for field housing are also available as well as rail-mounted housing in control cabinets
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Analog 2-Wire-Transmitter
Analog two-wire transmitters are used for direct connections of thermocouples or resistance thermometers. The design for thermocouples has a built-in reference junction and is available for a multitude of thermocouple types. The transmitter converts the signal from the temperature sensor into a standard signal of 4 … 20 mA (current loop). Depending on the design the signal is displayed temperature-linear (resistance thermometer) or EMF-linear (thermocouple).
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Analog Transmitter Type AT-W
Model with potentiometer
This model is designed for direct connection of resistance thermometers. The transmitter converts the signal from the temperature sensor into a standard signal of 4 … 20 mA.
The AT-W transmitter is available in intrinsically safe design EEx ia II C T6 according to EN 50020.
Prefered is the mounting in the lid of the connection head or directly on the measuring insert.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Analog Transmitter Type AT-W OP
Model with potentiometer
This model is designed for direct connection of resistance thermometers. The transmitter converts the signal from the temperature sensor into a standard signal of 4 … 20 mA.
This transmitter is without potentiometer for zero and span adjustment. The AT-W transmitter is available in intrinsically safe design EEx ia II C T6 according to EN 50020.
Prefered is the mounting in the lid of the connection head or directly on the measuring insert.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Analog Transmitter Type KAT-RW and KAT-RT
Model with potentiometer
This model is designed for direct connection of resistance thermometers and thermocpuples. The design for thermocouples has a built-in reference junction and is available for a multitude of thermocouple types. The transmitter converts the signal from the temperature sensor into a standard signal of 4 … 20 mA (current loop). Depending on the design the signal is displayed temperature- linear (resistance thermometer) or EMF-linear (thermocouple). We supply transmitters with potentiometer for calibration point of zero and span.
The electromagnetic compatibillity is complies acc. standard of industry to EN 50081 and EN 50082.
Prefered is the mounting in the lid of the connection head or directly on the measuring insert.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Analog Transmitter Type KAT-W OP and KAT-T OP
Model with potentiometer
This model is designed for direct connection of potentiometer, resistance thermometers and thermocouples. The design for thermocouples has a built-in reference junction and is available for a multitude of thermocouple types. The transmitter converts the signal from the temperature sensor into a standard signal of 4 … 20 mA (current loop). Depending on the design the signal is displayed temperature- linear (resistance thermometer) or EMF-linear (thermocouple). We supply transmitters with potentiometer for calibration point of zero and span.
The transmitters are supplied in intrinsically safe design acc. ATEX in EEx ia / ib II c T6. The electromagnetic compatibillity is acc. standard of industry to EN 50081 and EN 50082.
Prefered is the mounting in the lid of the connection head or directly on the measuring insert.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Analog Transmitter Type KAT-W and KAT-T
Model with potentiometer
This model is designed for direct connection of resistance thermometers and thermocouples. The design for thermocouples has a built-in reference junction and is available for a multitude of thermocouple types. The transmitter converts the signal from the temperature sensor into a standard signal of 4 … 20 mA (current loop). Depending on the design the signal is displayed temperature- linear (resistance thermometer) or EMF-linear (thermocouple). We supply transmitters with potentiometer for calibration point of zero and span.
The transmitters are supplied in intrinsically safe design acc. ATEX in EEx ia / ib II c T6. The electromagnetic compatibillity is acc. standard of industry to EN 50081 and EN 50082.
Prefered is the mounting in the lid of the connection head or directly on the measuring insert.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Programmable Two-Wire Transmitter
The programmable two-wire transmitter combines all the advantages of analog 2-wire transmitters with being in addition programmable. Using a standard PC and an interface adapter (RKA) all important parameters like measuring range, sensor type, etc. can be preset. Thus only one design is needed for all applications. In addition the programmable transmitters possess a galvanic insulation between input and output signal.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Programmable Transmitter Type RT
Two-wire transmitter for mounting in sensor-heads, field-housings or control panels.
Transmitters convert the low-level signal from thermocouple or resistance thermometer into a high-level standard signal. The non-linear input from temperature sensors is converted into a temperature- or EMF - linear output signal, depending on programming, of 4... 20mA.
The microcomputer-controlled system reduces the type and range variety, usual with analog transmitters, to only one model. Significant lowered inventory costs, universal use, short change - over and shut - down times are the advantages.
For maximum operational safety and reliability in harsh ambient conditions like vibrations no mechanical components (potentiometers) are involved whereever possible. Extensive calculations like drift/offset compensation, linearisation, limit comparison are done ''on site'' which means immedialely close to the sensor.
For the transmitter configuration a RS232-interface adapter is available. A comfortable user-friendly software in Windows - technique is used for programming communication and operation. Standard parameters are available via the RS232-interface as well as the measuring value, limits, cool joint temperature and so on without affecting the analog output of 4 to 20 mA.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Programmable Transmitter Type RT-H
HART-Communication Two-wire transmitter for mounting in sensor-heads, field-housings or control panels.
Transmitters convert the low-level signal from thermocouple or resistance thermometer into a high-level standard signal. The non-linear input from temerature sensors is converted into a temperature or EMF - linear output signal, depending on programming, of 4 ... 20mA. The transmitter uses the HART - protocol and frequency shift keying on the 4 - 20 mA current output loop.
This system ensures either a multi - drop communication with up to 15 units or full operation as a - wire transmitter in a 4 - 20 mA current loop. The microcomputer-controlled system reduce type and range variety, usual with analog transmitters, to only one model. Significant lowered inventory costs, universal use, short change - over and shut - down times are the advantages.
For maximum operational safety and reliability in harsh ambient conditions like vibrations no mechanical components (potentiometers) are involved whereever possible. Extensive calculations like drift/offset compensation, linearisation limit comparision are done ''on site'' which means immediately close to the sensor. For the transmitter configuration a HART - interface as well as f.e. the measuring value, limits, cool joint temperature and so on without affecting the analog output of 4 to 20 mA.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Programmable Transmitter Type RT-R
Programmable two-wire transmitter for use in measurement and control systems. Transmitters convert the low-level signal from thermocoupples or resistance thermometers into a high-level standard signal. The non-linear input from temperature sensors is converted into a temerature- or EMF-linear output signal, depending on programming, 4... 20mA.
The microcomputer-controlled system reduces the type and range variety, usual with analog trasmitters, to only one modell. Significant lowered inventory costs, universal use, short change-over and shut-down times are the advantages.
Extensive calculations like drift/offset compensation, linearisation, limit comparison are done `on site`, which means immediatly close to the sensor. For the transmitter configuration a RS232-interface is available. A comfortable user-friendly software is used for programming communication and operation. Standard parameters available via the RS232-interface as well as p.e. the measuring value, limits, cool joint temperature etc. withhout affecting the analog output of 4 ... 20 mA.
Our model RT-R is especially designed for use in small and wall-mounted housings. The compact size of the rail-mounted housing (only 22.5 mm width) allows a high packing density in the mostly rare cabinet space. The small height of 104 mm makes a double-stage mounting possible. In most cases an extension of existing systems is easy to realise.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Programmable Transmitter Type RT-RH
HART-Communication rail-mounted two-wire transmitter for use in measurement and control systems.
Transmitters convert the low-level signal from thermocoupple or resistance thermometer into a high-level standard signal. The nonlinear input from temperature sensors is converted in a temperature- or EMF-linear output signal, depending on programming, of 4 ... 20 mA. The transmitter uses the HART- communication principle, i. e. HART- protocol and frequency shift keying on the 4 ... 20 mA current output loop.
The system ensures either multi- drop communication with up to 15 units or full operation as a 2-wire transmimtter in a 4 ... 20 mA current loop. Extensive calculations like drift/offset compensation, linearisation, limit comparison are done `on site`, which means immediately close to the sensor. For the transmitter configuration a HART- interface is available. A comfortable user-friendly software is used for programming communication and operation. Standard parameters available via the HART-interface as well as i.e. the measuring value, limits, cool joint temperature etc. without affecting the analog output of 4 ... 20 mA.
Our model RT-RH is especially designed for use in small and wall-mounted housings. The compact size of the rail-mounted housing (only 22.5 mm width) allows a high packing density in the mostly rare cabinet space. The small height of 104 mm makes a double-stage mounting possible. In most cases an extension of existing systems is easy to realise
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik Cables & Accesssories
ROESSEL-Messtechnik supplies the complete line of accessories for temperature measurement.
Accessories like extension cables, connection heads, protective armatures and compression fittings, flanges, protection tubes, ceramic sockets, insulation rods, connector systems, etc.
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik 134646-2K TEMPERATURE SENSOR
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik 119297-2K TEMPERATURE SENSOR
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik 451109 TEMPERATURE SENSOR Pt 100
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik 6-0545-00012 TEMPERATURE SENSOR Pt 100
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik 138062 TEMPERATURE SENSOR Pt 100
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik PT100
TEMPERATURE SENSOR PLATINUM RESISTANCE
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik PT100-6-0520-00240
TEMPERATURE SENSOR PLATINUM RESISTANCE 4-20MA
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik 138039-2K
THERMOCOUPLE W/UNSHIELDED PROBE
ROESSEL-Messtechnik / Rössel-Messtechnik / Rossel-Messtechnik 2-0520-00571-11
Türkiyede ROESSEL-Messtechnik ürünleri ile ilgili uygun rekabetçi fiyatları almak için müşteri temsilcimizle ( http://www.imajteknik.com.tr/bize-ulasin ) veya Fiyat teklifi formunu ( http://www.imajteknik.com.tr/online-iletisim-formu ) doldurarak mesaj bırakmanız halinde satış mühendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.