Schleicher Electronic

Schleicher Electronic

 

Safety Relays

 
SNO 4062K

Safety Relay

SNO 5002K plus

Safety relay for emergency stop and guard door applications
SILCL2 in accordance with EN 62061, PL d, Category 3 in accordance with EN ISO 13849-1, in accordance with EN ISO 13849-1, Stop category 0 in accordance with DIN EN 60204-1, Manual or automatic start
With cross circuit detection of the reset inputs, Feedback circuit for external contactor monitoring, 2 enable circuits, NO positively guided, 1 signaling current path, Input debouncing, Error message from SUPPLY-LED

Safety Relay

SNO 4063KM

Base unit for emergency stop and guard door applications
Base unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring.
PL e and category 4 as per EN ISO 13849-1, Stop category 0 as per DIN EN 60204-1, Manual or automatic start, With / without cross short detection, Feedback circuit for external contactor monitoring, 3 enable circuits, NO positively guided, For processing signals from the output signal switching devices (OSSD) of a light curtain, according to DIN EN 61496-1, For post-switching a switching mat according to DIN EN 1760-1 (SNO 4063KM), Input debouncing (SNO 4063KM)

Safety Relay

SNO 4063K

Based devices for emergency stop, safety gate applications, 
Basic unit according to DIN EN 60204-1 and EN ISO 13849-1, for single or dual channel emergency stop monitoring PL eand category 4 according to EN ISO 13849-1, Stop Category0 according to EN 60204-1, Manual or automatic start, with /without cross monitoring, feedback loop for monitoring external contactors, 3 enabling current paths, contact, positively driven to processing of signals from the output switching elements (OSSD) of a light curtain according to DINEN 61496-1, for downstream connection to a safety mat in accordance with DIN EN 1760-1 (SNO 4063KM), debounce(SNO 4063KM)

Safety Relay

SNO 4062KM

Basic unit for emergency stop and guard door applications
Basic unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring.
PL e and category 4 as per EN ISO 13849-1, SILCL 3 as per DIN EN 62061, Stop category 0 as per DIN EN 60204-1, Manual or automatic start, With/without cross short detection, Feedback circuit for external contactor monitoring, 2 enable circuits, 1 signal circuit, For processing signals from the output signal switching devices (OSSD) of a light curtain, according to DIN EN 61496-1, For post-switching a switching mat according to DIN EN 1760-1 (SNO 4062KM), Input debouncing (SNO 4062KM)

Safety Relay

SNO 4062K

Basic device for emergency stop and safety doorapplications, the basic unit according to DIN EN 60204-1 andEN ISO 13849- 1 for single or dual channel emergency stopmonitoring, PL e and category 4 according to EN ISO 13849-1, SILCL 3 according to DIN EN 62061 stop category 0according to EN 60204-1, Manual or automatic start, with /without cross monitoring, feedback loop for monitoring external contactors, 2 enabling current paths, 1 signaling current path, for processing signals from the output switchingelements (OSSD) of a light grid according to DIN EN 61496-1, for downstream connection to a safety mat in accordance with DIN EN 1760-1 (SNO 4062 KM), debounce (SNO 4062KM)

Safety Relay

SNO 4003K plus

The unit is designed for single or twin channel control as a contact expansion.
SNE 4003K with screw terminals, fixed
PL e and category 4 as per EN ISO 13849-1, SILCL3 as per EN 62061, Stop category 0 and 1 DIN EN 60204-1
Safe insulation as per DIN EN 50178, Single or twin channel control, 1 feedback current path (NC), 3 enable current paths (NO), 1 signal current path (NC), Suitable for semiconductor control

Safety Relay

SNA 4064K

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4 and stop category 0, Single or twin channel control, With or without cross short detection, Reset, manually monitored SNA 406xK or automatic SNA 404xK, 4 release current circuits SNA 40x4K or 3 release current circuit, 1 signal generator current circuit SNA 40x3K

Safety Relay

SNA 4063K

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4 and stop category 0, Single or twin channel control, With or without cross short detection, Reset, manually monitored SNA 406xK or automatic SNA 404xK, 4 release current circuits SNA 40x4K or 3 release current circuit, 1 signal generator current circuit SNA 40x3K

Safety Relay

SNA 4044K

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4 and stop category 0, Single or twin channel control, With or without cross short detection, Reset, manually monitored SNA 406xK or automatic SNA 404xK, 4 release current circuits SNA 40x4K or 3 release current circuit, 1 signal generator current circuit SNA 40x3K

Saftey Relay

SNA 4043K

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4 and stop category 0, Single or twin channel control, With or without cross short detection, Reset, manually monitored SNA 406xK or automatic SNA 404xK, 4 release current circuits SNA 40x4K or 3 release current circuit, 1 signal generator current circuit SNA 40x3K

Safety Relay

SNE 4004KV

Extension unit for safety switchgear
Expansion unit as per EN 60204-1 and EN ISO 13849-1; PL e and category 4 as per EN ISO 13849-1; SILCL3 as per EN 62061; Single or twin channel control; 4 enable circuits; 2 signal circuits; 1 feedback circuit; With fall-back delay and time buffering (SNE 4004KV)

Safety Relay

SNE 4004K

Extension unit for safety switchgear
Expansion unit as per EN 60204-1 and EN ISO 13849-1, PL e and category 4 as per EN ISO 13849-1, SILCL3 as per EN 62061, Single or twin channel control, 4 enable circuits, 2 signal circuits, 1 feedback circuit, With fall-back delay and time buffering (SNE 4004KV)

Safety Relay

SNV 4063KL

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4/3 and stop category 0/1, Single or twin channel control via contacts or semi-conductors, Cross short detection, simultaneity monitoring
Reset button monitor, 3 release current circuits (2 without delay, 1 fallback delayed)

Safety Relay

SNV 4063KP

Basic unit for emergency stop and guard door applications
Basic unit as per EN 62061 and EN ISO 13849-1, For safety category 4/3 and stop category 0/1, Single or twin channel control via contacts or semi-conductors, Cross short detection, simultaneity monitoring
Reset button monitor, 3 release current circuits (2 without delay, 1 fallback delayed)

Safety Relay

SNE 4003K

Relay output extension for safety switching devices; with single or two-channel control; by contacts or semiconductors; Input voltage range DC 15 - 30 V; Stop category 0 and 1 according to EN 60204-1; Application up to safety category 4 according to EN 954-1; Safe isolation according to EN 50178; Contact equipment, positive action: 3 NO (shares), 2 NC contacts (signaling contacts); Rated voltage: 24 V DC;Connectivity Technology (specify when ordering): fixed screw, screw plug; Mounting: DIN rail; Width: 22.5 mm;

Safety Relay

SNZ 4052K plus

Safety relay for two-hand module (EN 574, TYPE IIIC)
in accordance with EN 62061 to SILCL3, in accordance with EN ISO 13849-1 to PL e and Category 4, Cross short detection for input circuits, Feedback circuit for external contactor monitoring, 2 release current circuits, NO contact positively guided, 1 signal generator current circuit, Error message from SUPPLY LED
 

Safety Relay

SNO 2005

Basic unit for emergency stop and guard door applications
Basi unit as per DIN EN 60204-1 and EN ISO 13849-1, PL e / category 4 as per EN ISO 13849-1, Stop category 0 as per DIN EN 60204-1, SILCL 3 as per DIN EN 62061, Cross-over detection with feedback circuit for monitoring external contactors, One or twin channel emergency stop or guard door monitoring, 3 enable circuits, 1 signal circuit

Measurement and Monitoring Devices  

 

Measurement and Monitoring Device

SST 12

Contact protection relays, power supply andcontrol circuit electrically isolated, response time and delay on release from 0.05 to 1 sadjustable contacts: 2 changeover contacts, rated voltage: (specify when ordering) AC 24 V50 - 60 Hz, AC 110-127 V 50 - 60 Hz , AC 220- 240 V 50 - 60 Hz, screw clamps; Mounting:DIN rail; Width 45 mm

Measuring and monitoring relay

STW 1002

Temperature controller for thermocouple NiCr-Ni, Temperature Range 0 to + 999 ° C, hysteresis adjustable, Digital limit setting, cold junction temperature +25 ° C, monitoring the sensor cable for breaks, with closed-circuit principle

Measuring and monitoring relay

STW 1001

Temperature controller for thermocouple NiCr-Ni, Temperature Range 0 to + 999 ° C, hysteresis adjustable, Digital limit setting, cold junction temperature +25 ° C, monitoring the sensor cable for breaks, open-circuit principle, nominal voltage: (specify when ordering) DC24V, AC 220-240 V 50 - 60 Hz, 1 changeovercontact assembly, screw clamps, mounting: DIN rail, Width 45 mm

Measuring and monitoring relay

STW 1102

Temperature controller for thermal resistancePt 100 Temperature range 0 to +799 ° C, adjustable hysteresis, Digital limit setting, monitoring of the sensor cable for breaks andshort circuits, linearity error of the sensorcompensated, closed-circuit principle,Nominalvoltage AC 220 - 240V 50 - 60 Hz, 1 changeover contact assembly, screw clamps, mounting: DIN rail; Width 45 mm

Measuring and monitoring relay

STW 1101

Temperature controller for thermal resistancePt 100 Temperature range 0 to +799 ° C, hysteresis adjustable, Digital limit setting, monitoring of the sensor cable compensatedfor break and short-circuit, linearity error of the sensor circuit principle, nominal voltage AC220 - 240V 50 - 60 Hz, Contact configuration 1 CO contact, screw terminals fixed, mounting:DIN rail; Width 45 mm

Measuring and monitoring relay

SMS 1006

Motor protection relay / temperature monitor for cold-wire connection, with reclosing lockout, one monitoring circuit for PTC thermistor according to DIN EN 60947-8, error memorywith reset button and restart lockout, breakage and short circuit monitoring of the sensor cable, closed circuit principle; Contacts 2 CO contact, Rated voltage AC 220 - 240 V 50 - 60Hz, screw clamps, mounting: DIN rail; Width 45mm

Measuring and monitoring relay

SMS 1005

Motor protection relay / temperature monitor for cold-wire connection, one monitoring circuitfor PTC thermistor according to DIN EN60947-8, breakage and short circuit monitoringof the sensor cable, closed circuit principle; with fault latch, reset button or reset via the power supply, Contacts 2 CO contact, Ratedvoltage AC 220 - 240 V 50 - 60 Hz, screw clamps, mounting: DIN rail; Width 45 mm

Measuring and monitoring relay

SMS 1002

Motor protection relay / temperature monitor for cold-wire connection, one monitoring circuitfor PTC thermistor according to DIN EN60947-8, breakage and short circuit monitoringof the sensor cable, closed circuit principle, Contact arrangement 1 CO contact, Ratedvoltage: (specify when ordering) 
AC 24 V 50-60 Hz, AC 110-127 V 50-60 Hz, AC 220-240 V 50-60 Hz, screw clamps, mounting: DIN rail; Width 45 mm

Measuring and monitoring relay

SBW 1007

Overload detection of electric motors without additionalpickup; Measuring voltage: 3 x AC 380 - 415V / 5A 50 - 60Hz; Start-up delay from 1.5 to 30 s adjustable; Fault memorycan be activated by jumper; Closed-circuit principle; Contact configuration 1 CO contact; Screw clamps; Mounting: DIN rail; Width 45 mm; Accessories (not included): Cover Z29

Measuring and monitoring relay

SBW 1005

Underload detection of electric motors; without additionalpickup; Measuring voltage: (specify when ordering) 3 x AC 380 -, 60 Hz - 415V / 5A 50, 3 x AC 440 - 480V / 5A 50 - 60Hz; Start-up delay from 1.5 to 30 s adjustable; Fault memorycan be activated by jumper; Closed-circuit principle; Contact configuration 1 CO contact; Screw clamps; Mounting: DIN rail; Width 45 mm; Accessories (not included): Cover Z29

Measuring and monitoring relay

SUW 3001

Three-phase voltage monitor without auxiliary voltage;Undervoltage detection of 1, 2, 3 phases; Setting range 285-360 V; Phase failure detection of 1, 2, 3 phases; Response time 35 ms; Closed-circuit principle; Contacts 2 changer; Nominal voltage 3 x 400 V AC 50-60 Hz; Screw clamps; Mounting: DIN rail; Width 45 mm

Measurement and Monitoring Device

SBW 1004

Low load recognition of electric motors without additional pickup sensor
Alternating current and AC current mains, Startup bridging time adjustable, With and without error memory
Operating or standby current principle, SBW 1004 with operating current principle, SBW 1005 with standby current principle

Measurement and Monitoring Device

SAP 1002

Alternating current phase sequence relay without auxiliary voltage
Detection of incorrect phase sequence, Standby current circuitry, Contact allocation: SAP 1002 1 changer, SAP 1003 2 changers

Measurement and Monitoring Device

SAP 1003

Alternating current phase sequence relay without auxiliary voltage
Detection of incorrect phase sequence, Standby current circuitry, Contact allocation: SAP 1002 1 changer, SAP 1003 2 changers

Measurement and Monitoring Device

SPW1005

Alternating current phase sequence-phase error relay without auxiliary voltage
Detection of incorrect phase sequence, Detection of phase-voltage asymmetry, Phase failure detection, also for reverse polarity voltage with and without phase offset, Adjustable alternating current Nominal voltage 3 AC 380 V, 400 V, 415 V with associated low voltage recognition, of one, two and all three phases, Standby current principle, reaction time 35 ms at each fault recognition, Contact allocation: SPW 1004 2 changer, SPW 1005 1 changer
 

Measurement and Monitoring Device

SPW 1004

Alternating current phase sequence-phase error relay without auxiliary voltage
Detection of incorrect phase sequence, Detection of phase-voltage asymmetry, Phase failure detection, also for reverse polarity voltage with and without phase offset, Adjustable alternating current Nominal voltage 3 AC 380 V, 400 V, 415 V with associated low voltage recognition, of one, two and all three phases, Standby current principle, reaction time 35 ms at each fault recognition, Contact allocation: SPW 1004 2 changer, SPW 1005 1 changer
 

Measurement and Monitoring Device

SAM 1001

Three-phase unbalanced – phase sequence – phase failure relays without auxiliary supply voltage
Detection of incorrect phase sequence, Detection of the failure of one or more phases, Recognition of voltage feedback in the event of phase failure, Adjustable phase voltage imbalance, Closed-circuit principle, Contact assignment: 2 change-over contacts

Measurement and Monitoring Device

SUW 1001

Direct or alternating voltage monitor without auxiliary voltage
For single-phase networks, Large setting range and large operating range, Adjustable maximum and minimum limit, Standby current principle

Measurement and Monitoring Device

SXT 32

Voltage- or current-measuring relay
For falling below or exceeding the limit value of single-phased currents or voltages, Response value in Ratio 1 : 10 adjustable, Fallback value (from 50 to 95 % of the response value) adjustable, With auxiliary voltage, Standby current principle 
 

Measurement and Monitoring Device

SXT 12

Voltage- or current-measuring relay
For falling below or exceeding the limit value of single-phased currents or voltages, Response value in Ratio 1 : 10 adjustable, Fallback value (from 50 to 95 % of the response value) adjustable, With auxiliary voltage, Operating current principle 
 

Measurement and Monitoring Device

SIM 1001

Current measuring relay
For falling below or exceeding the limit value of single-phased currents, 2 versions, each with three operating ranges from AC/DC 2 to 500 mA and/or 0.1 to 15 A, Curve shape: sine, square, triangle, 10 time domains: non-delayed, 0.1 s to 3 h for the response time delay, Frequency range of the measured variable from 45 to 400 Hz, Multifunction: Operating or standby current principle, hysteresis 3 % or 10 % of the target value
 

Measurement and Monitoring Device

SUM 1001

Voltage measuring relay
For failing to meet and for exceeding the threshold value of single-phased voltages, operating ranges AC/DC: 0.5 to 500 V, Curve shape: sine, square, triangle, 10 time domains: non-delayed, 0.1 s to 3 h for the operate time delay, Frequency range of the measured variable from 45 to 400 Hz, Multifunction: Operating or rest current principle, hysteresis 3 % or 10 % of the target value
 
 

 

Timer Relays

Timer and Switching devices

DZE 12-SL

Devices for mono-voltage
Response delay (RD), 1 Time range, Contact complement:
DZE 12-SL: 1 immediate and 1 delayed,  changeovers, DZE 34-2SL: 1 immediate and 1 delayed
make-break contacts, • Front dimensions: 2.83 x 2.83 inch / 72,0 x 72,0 mm

Timer and Switching Devices

DZE 34-2SL

Devices for mono-voltage
Response delay (RD), 1 Time range, Contact complement:
DZE 12-SL: 1 immediate and 1 delayed,  changeovers, DZE 34-2SL: 1 immediate and 1 delayed
make-break contacts, • Front dimensions: 2.83 x 2.83 inch / 72,0 x 72,0 mm

Timer and Switching Devices

SSPE 34

Eectromechanical elementary relay, Balanced-beam relay, 4 Changer,  24V AC/DC to 230 V AC/DC, nomial voltage 50 und 60 Hz, enabling current path 400V AC/30V DC, DIN EN 60664-1: 2008-01; VDE 0110-1: 2008-01, rated impulse voltage 4kV, overvoltage category III, IP30/IP20

Timer and Switching Device

NGZP 72

ON-delay multi-range timer relay with remote potentiometer connection
Multi voltage for AC/DC 24 up to 240 V, 1 function: ON-delay (AV), Setting range from 0.1 s to 300 h divided into 16 selectable time ranges, Remote potentiometer connection, 2 change-over contacts, LEDs for function display

Timer and Switching Device

NGMP 1001

Multi-function multi-range timer relay withremote potentiometer connection, 1 PDT, multi-voltage AC / DC 24 to 240 V, 10 Functions, Setting range from 0.1 s to 300 h divided into 16 selectable time ranges, remote potentiometer connection, 2 LEDs for function display

Timer and Switching Device

NGD 32

Star-delta-delay relay, multi-voltage AC / DC24 to 240 V, 2 NO, 1 function: star delta switching, delay (AV), 3 time ranges available from 0.5 s to 100 s, 2 LEDs for function display

Timer and Switching Device

SSY 12

Interval ON and/or OFF fixed timer relay
Single voltage, 1 function: Interval ON and/or OFF (EAW), Fixed interval time 0.5 s, 1 interval change-over contact and 1 interval NO
 

Timer and Switching Device

KMZ 72

Multi-function multi-range timer relay
Multi voltage for AC/DC 24 up to 230 V, 4 functions, Setting range from 0.1 s to 120 h divided into 7 time ranges, 1 instantaneous and 1 timed change-over contact or 2 timed change-over contacts (selectable) 1 interval NO

Timer and Switching Device

KSP 12

Electronic flip-flop relay
Mono voltage, 1 Function: flip-flop relay, 1 changer, 1 NO contacterval NO

Timer und Switching Device

KPT 11KD

Multi range repeat cycle timer
Dual voltage, 1 function: KPT 11 KD: repeat cycle starting with OFF (TP), KPT 31 KD: repeat cycle starting with ON (TI), Setting range from 0.05 s to 10 h divided into 10 time ranges, 1 change-over contact, 2 LEDs for function display

Timer and Switching Device

DZD 92-L

Analog / digital multi-function multi-Timer relay, 
Display digital and analog, Contacts 2changers (function adjustable), rated voltage: (specify when ordering) 24 V DC, 24 V AC 50-60 Hz, 42 V AC 50-60 Hz, AC 115 V 50-60 Hz, AC 230 V 50-60 Hz, 8 Functions response delay time range 100 h, the time domain is divided into 7 setting, off delay, clock, andcombinations, mounting: panel mounting

Timer and Switching Devices

KMZ 92

Multi-function multi-range timer relay
Multi voltage for AC/DC 24 up to 230 V, 8 functions, Setting range from 0.1 s to 120 h divided into 7 time ranges, KMZ 92 = 1 instantaneous and 1 timed change-over contact or 2 timed change-over contacts (selectable)

Timer and Switching Device

NGM 1004

Multi-function multi-range timer relay
Multi voltage for AC/DC 24 up to 240 V, 10 functions, Setting range from 0.1 s to 300 h divided into 16 selectable time ranges, 1 change-over contact, 2 LEDs for function display

Timer and Switching Device

UZD 51

Digital multi-function multi-range relay
Multi-voltage for AC 100 to 240 V, Mono-voltage for AC/DC 24 V, 8 functions, 2 color high-contrast LCD displays, Setting range digital 0.001 s to 999.9 h split into 8 time ranges, Zero-voltage secure, 1 timed change-over contact

Timer and Switching Device

SSPE 56

Electromechanical elementary relay
Balanced-beam relay, break contacts, 3 make contacts, 24 V AC/DC bis 230 V AC/DC, 50 and 60 Hz
Max. UN 120 mA, 0.8 bis 1.1 x UN

Timer and Switching Device

NGZP 32

ON-delay single-range timer relay with remote potentiometer connection
Multi voltage for AC/DC 24 to 240 V, 1 function: ON-delay (AV), 13 time ranges available from 0.1 s to 100 h
Remote potentiometer connection, 2 change-over contact, 2 LEDs for function display

Timer and Switching Device

NGZ 720

OFF-delay multi-range timer relay with auxiliary supply
Multi voltage for AC/DC 24 up to 240 V, 1 function: OFF-delay (RV) with auxiliary supply, Setting range from 0.1 s to 300 h divided into 16 selectable time ranges, 2 change-over contact, 2 LEDs for function display

Timer and Switching Device

NGZ12-S

ON-delay single-range timer relay
Multi voltage for AC/DC 24 up to 240 V, 1 function: ON-delay (AV), 13 time ranges available from 0.1 s to 100 h, 1 change-over contact, 2 LEDs for function display

Timer and Switching Device

NGZ 12

ON-delay single-range timer relay
Multi voltage for AC/DC 24 up to 240 V, 1 function: ON-delay (AV), 13 time ranges available from 0.1 s to 100 h, 2 change-over contact, 2 LEDs for function display

Timer and Switching Device

NGS 12

Electronic coupling relays
4 mono voltages AC/DC available, 1 function: coupling relay, 2 change-over contacts, 1 LED for function control

Timer and Switching Device

NGZ 72

ON-delay multi-range timer relay with remote potentiometer connection
Multi voltage for AC/DC 24 up to 240 V, 1 function: ON-delay (AV), Setting range from 0.1 s to 300 h divided into 16 selectable time ranges, Remote potentiometer connection, 2 change-over contacts, LEDs for function display

Timer and Switching Device

NGM 1600

Multi-function multi-range timer relay
Multi voltage for AC/DC 24 up to 240 V, 16 functions, Setting range from 0.1 s to 300 h divided into 16 selectable time ranges, 2 change-over contacts or 1 instantaneous change-over contact and 1 timed change-over contact (function-dependent), 3 LEDs for function display

Timer and Switching Device

NGD 31

Interval ON star-delta relay
Multi voltage for AC/DC 24 up to 240 V, 1 function: star-delta switching, interval ON (EW), 3 time ranges available from 0.5 s to 100 s, 2 normally open contacts, 2 LEDs for function display

Timer and Switching Device

NGB 12

Fixed time flasher relay
Multi-voltage for AC/DC 24 to 240 V, 1 function: symmetrical flashing, starts OFF, Fixed time 0.5 s / 0.5 s
2 change-over contact, 2 LEDs for function display

Timer and Switching Device

KZTH 11

ON-delay single-range timer relay with semiconductor output (two-wire)
Multi voltage AC/DC 24 to 110 or 60 to 230 V, 1 function: ON-delay (AV), 1 time range, 1 semiconductor output

 

Schleicher Electronic Ürünleri ile uygun rekabetçi fiyaları almak için müşteri temsilçimiz ile  http://www.imajteknik.com.tr/bize-ulasin veya Fiyat teklifi formunu doldurarak mesaj bırakmanız halinde satış muhendislerimiz en kısa zamanda sizinle irtibat kuracaklardır.

Schleicher Electronic markasına ait tüm ürünler

    0 kayıt bulundu