Quarity Control
Data Printers / Application Software
Quality Control Printer (LDM-100QC):
A unit to print out statistical calculating value necessary to quality control such as average, standard deviation, histogram, etc.
Counting Event Printer (AD-50):
This unit is to print out continuously distance message at the time when alarm signal is received.
Printer for LASER DIAMETER (RS-Printer):
RS-PRINTER takes through the RS-232C interface and prints the display value from Takikawa’s Laser Diameter
LASER DIAMETER MEASUREMENT SYSTEM ( LDM-PC EX )
It is application software to take the result measured with the LASER DIAMETER made of our company from the display part into PC by serial communications (RS-232C), and to file the graph print and the measurement result.
Type
|
Quality Control Printer
|
Model
|
LDM-100QC
|
Input
|
BCD data input
(RS-232C or Analog deviation voltage is also available by option.)
|
Setting items
|
Center value, Upper value, Sampling method, Sampling period,
No. of data, Histogram width, Date
|
(Battery backuped)
|
Printer
|
Thermal type. 27-digit. 58mm wide
|
Print out contents
|
Each set item, T-graph(Real time), Histogram, No. of data, Max. value, Min. value, Range, Average, Standard deviation, Variance, Deviation, Process capability index, Bias for specification
|
Display
|
20 digits * 2 lines LCD with Back light
|
External input
|
Start/Stop, Hold(Trigger)
|
Power supply
|
AC100 - 240V Free power supply 50/60Hz, less than 10VA
|
Outside dimension
|
350(W) * 99(H) * 331(D)[mm]
|
Weight
|
3.5kg
|
Accessory cable
|
BCD cable 1pcs.
|
Ambient condition
|
Temperature: 0 - 45 degree centigrade, Humidity:35 - 85%RH(No condensation)
|
Alarm Unit
This unit makes alarm by both buzzer and light.
Alarm unit -- Specifications
Type |
Alarm unit |
Model |
AL-03 |
Summary |
This unit makes alarm by both buzzer and light by recieving alarm signal and memorizes number of alarms in panel counter |
Input |
Non-voltage contact signal(On-time:More than 0.1sec) |
Output |
Light and buzzer (Memorized to counter) |
Reset input |
Reset switch on front panel turns off Light and buzzer |
Outside dimension |
110(W) * 315(H) * 85(D)[mm] |
Power supply |
AC100V 50/60Hz 15VA |
External Display Unit
DSP@Series -- Specifications
Type |
External Display Unit |
Model |
DSP-4 |
DSP-48 |
Summary |
This unit indicates measuring values by BCD data of
Laser Micormeter at far distance place by BCD signal. |
Power supply |
AC100V 50/60Hz |
AC100 - 240V 50/60Hz |
Input |
BCD, Open collector input(Negative logic) |
Max. cable length |
100m |
Display |
4-digit Red 7-segment LED
Char. height:15mm |
4-digit Orange 7-segment LED
Char. height:76.2mm |
Outside dimension |
72(W) * 36(H) * 137.5(D)[mm] |
310(W) * 140(H) * 140(D)[mm] |
Others
HIGH SPEED PRINTER
PREHEATER
INDUCTION PREHEATER
Preheater of SungMin Instruments has wide
application range. The conductor should be preheated when the cable wire extruding is processing. For AL strip annealing. Preheat wire before the process of the wire coating for wire-net. Preheater attached communication-wire capstan. * It's very effective to marker high quality and productivity through the process of preheating the iron or nonferrous-metal
INVERTER PREHEATER
- * Preheater of SungMin Instruments has wide application range.
The conductor should be preheated when the cable wire extruding is processing.
For AL strip annealing.
Preheat wire before the process of the wire coating for wire-net.
Preheater attached communication-wire capstan.
- * It's very effective to marker high quality and productivity through the process of preheating the iron or nonferrous-metal
INDUCTION PREHEATER-- Specifications
Model |
Wire Size |
TEMP. Set Range |
kVA |
Pulley |
IP-200P15 |
0.5 - 3mm |
299 |
15kVA 50/60Hz |
200mm x 2 |
IP-220P20 |
1 - 5mm |
299 |
20kVA 50/60Hz |
220mm x 2 |
IP-300P20 |
2 - 6mm |
299 |
20kVA 50/60Hz |
300mm x 2 |
IP-300P30 |
2 - 8mm |
299 |
30kVA 50/60Hz |
300mm x 2 |
IP-400P50 |
3 - 10mm |
299 |
50kVA 50/60Hz |
400mm x 2 |
IP-600P50 |
5 - 15mm |
299 |
50kVA 50/60Hz |
600mm x 2 |
IP-800P50 |
5 - 20mm |
299 |
50kVA 50/60Hz |
800mm x 2 |
IP-1000P100 |
7 - 25mm |
299 |
100kVA 50/60Hz |
1000mm x 2 |
IP-1200P100 |
10 - 30mm |
299 |
100kVA 50/60Hz |
1000mm x 2 |
INVERTER PREHEATER-- Specifications
Model |
HP-120P15 |
HP-220P7 |
HP-220P15 |
HP-300P15 |
Pulley |
120mm x 3.150mm x 1 |
220mm x 2 |
220mm x 2 |
200mm x 2 |
Wire Size |
Steel , Cu , AL , Solid ,Stranded |
|
0.2 - 1.5mm |
0.5 - 3mm |
0.8 - 4.5mm |
Wire Temp.
Setting Range |
0 - 299 |
Wire Speed for 100 |
2000m/min |
600m/min |
2000m/min |
2000m/min |
Capacty |
220V. 15kVA |
220V. 7kVA |
220V. 15kVA |
220V. 15kVA |
Work Frequency |
1000Hz |
Remote control |
0 - 10V DC Input |
Work Volt |
0 - 70V |
0 - 40V |
0 - 70V |
0 - 40/70V |
Power Supply |
220/380VAC 3Phase 50/60Hz |
TALC MASTER
* TALC MASTER is a machine which can make can make an even application of the talc powder to the core wire for an easy separation from its covering material, when necessary.
* It has some special characteristics in that it can minimize the consumption of the talc powder;
It can control the quantity of the powder in proportion to the speed of the wire production.
Powder jet spray by a high pressure blower is possible.
* Quality application of the powder is guaranteed by using the electrostatic collector.
Three circulation filters are in use.
Model |
TM-E40 |
TM-E70 |
Type |
Electrostatic Powder Application |
Wire Size |
Max.40 |
Max.70 |
Fault Alarm |
Blower, Screw, Electorostatic, Powder low |
TALC Powder |
DOSAGE Controller |
Center Height |
950 - 1150mm |
Compressure Air Supply |
4kgf/cm2 |
Scattering check equip |
Ring blower |
Heater |
1.5kW Plate heater |
Size
(W) x (H) x (D)mm |
750 x 1850 x 820 |
800 x 1850 x 1200 |
Static electricity voltage |
0 - 50/90kVDC |
Power Supply |
220VAC 50/60Hz 1Phase 3kW |
Butt Welding Machines
* By touch with each other process in the same
section, use to weld for a light alloy except copper and iron and to continuously work for invar or pressing up.
* A little change by heating and can quickly weld.
* Weld a suitable current electronic setting with using for SCR(Silicon Controlled Rectifier) running electronic control system according to material and thickness of welding materials.
Model |
Copper
sq.mm |
Aluminium
sq.mm |
Steel
sq.mm |
Transformaer
Rating |
Weight
GROSS |
Size
(W) x (H) x (D)mm |
type |
SM-5BW |
0.5 - 5 |
--- |
0.5 - 7 |
3kVA |
22kg |
350 x 880 x 250 |
Handle type |
SM-25BW |
3 - 25 |
8 - 40 |
10 - 45 |
14kVA |
24kg |
704 x 1310 x 568 |
Handle type |
SM-50BW |
15 - 50 |
20 - 70 |
20 - 76 |
20kVA |
250kg |
704 x 1310 x 568 |
Handle type |
SM-150BW |
20 - 150 |
30 - 180 |
36 - 200 |
50kVA |
780kg |
1350 x 1420 x 1400 |
Pneumatic Auto type |
SM-300BW |
30 - 300 |
40 - 400 |
50 -430 |
Inverter 70kVA |
840kg |
1350 x 1420 x 1400 |
Handle & Auto type |
SM-500BW |
60 - 500 |
50 - 600 |
60 - 690 |
Inverter 150kVA |
1050kg |
1350 x 1420 x 1400 |
Handle & Auto type |
*Input/Output Specifications
MODEL |
Input Power |
Output power |
SM-5BW |
220V AC 50/60Hz 1Phase |
0 - 9V 50/60Hz |
SM-25BW |
220V AC 50/60Hz 1Phase |
0 - 9V 50/60Hz |
SM-50BW |
220V AC 50/60Hz 1Phase |
0 - 9V 50/60Hz |
SM-150BW |
220V AC 50/60Hz 1Phase |
0 - 9V 50/60Hz |
SM-300BW |
220/380/440V AC 50/60Hz 3Phase |
0 - 30V 50/60Hz |
SM-500BW |
220/380/440V AC 50/60Hz 3Phase |
0 - 30V 50/60Hz |
CORONA MASTER
- This equipment is composed of the device generating high frequency and electrode unit.
- In electrode, high friquency high voltage generates corona dischage in contact with jacketd copper wire. So the surface of jacket (PE, PVC, TEFRON, HDPE, LDPE) is activated and the adhesion is strengthened in the second progress, stamping.
- Compact Size.
- Easy to adjust the electrode.
- High efficiency and with performance by using IGBT.
- The interlocking device maintains the safety in opetation
CORONA MASTER -- Specifications
Model |
CM-200 |
CM-400 |
CM-GAS |
Output Friquency |
20 - 25kHz |
20 - 25kHz |
GAS Flame |
Capacity |
1kVA |
3kVA |
1000 |
Output Voltage |
5 - 12kV |
3 - 10kV |
|
Electrode |
220mm |
800mm |
260mm BURNER |
Size(W)x(H)x(D) |
500 x 1425 x 620 |
600 x 1200 x 650 |
Power Supply |
220V AC 50/60Hz 1Phase |
Type
|
Counting Evint Printer
|
Model
|
AD-50
|
Counting value
display
|
6-digit, 2-color(Green/Red), 7-segment LED.
Zero suppress is available.
|
Input pulse for
length measuring
|
Single/Double(A,B) phase pulse input is available,
Up/Down counting is available
|
Pulse Edge
|
Rising or Falling
|
Pulse rate
|
Free setting between 0.00001m/pulse - 999999m/pulse
|
Max. Pulse
frequency
|
2kPPS or 100PPS
|
Count sensor
power supply
|
+12V 250mA
|
No of Events
|
10 (8 Events + RESET & PRINT)
|
Event input
|
From Rear panel terminal
|
RESET input
|
From Rear panel terminal & front panel push switch
|
PRINT input
|
From Rear panel terminal, front panel push switch & RS-232C
|
Message
Change method
|
By RS-232C interface
|
PRESET1 setting
|
6 digit
|
PRESET2 setting
|
6 digit
|
Initial setting
|
6 digit
|
Lot No. setting
|
4 digit. Automatic increment by RESET is available.
|
Event distance
compensation
|
Each event distance can be set.
|
PRESET outputs
|
Count value display into Red color 7-segment from Green,
Front panel LED, RS-232C,
Relay contact(1a-contact, AC250V Resistance load 2A)
|
Printer
|
Thermal type, 20 digit, 58mm wide
|
Out-of-paper
signal
|
Front panel LED, RS-232C,
Relay contact(1a-contact, AC250V Resistance load 2A)
|
Timing function
|
Year/Month/Date and Hour/Minute
|
Battery back-up
|
Back-up the counter value, timing, etc.
|
Communication
|
RS-232C interface (Baud rate:300 - 19200bps)
|
Power supply
|
AC100 - 240V Free power supply 50/60Hz, less than 8VA
|
Outside
dimention
|
144(W) * 144(H) * 191(D)[mm]
|
Weight
|
2.8kg
|
Ambient condition
|
Temperature:0 - 45 degree centigrage, Humidity:35 - 85%RH(No condensation)
|
Type
|
Printer for LASER DIAMETER
|
model
|
RS-PRINTER
|
Printer
|
Thermal type, 20 digit, 58mm wide
|
Corresponding Model
|
Connected by TAKIKAWA's LASER DIAMETER
LDM-110A110EXA210A210CA1000A1000EX
|
Communication rate
|
Difference depending on the model. An initial value is 9600bps.
|
Power supply
|
AC100 - 240V Free power supply 50/60Hz, less than 8VA
|
Outside
dimention
|
180(W)×90(H)×210(D)[mm]
|
Ambient condition
|
Temperature:0 - 45 degree centigrage, Humidity:35 - 85%RH(No condensation)
|
Type
|
LASER DIAMETER MEASUREMENT SYSTEM
|
model
|
LDM-PC EX
|
PC/OS to be used.
|
Meet the forrowing requirement.
|
IBM PC compatible (DOS/V machine): CD-ROM should be able to be used.
Indispensable, and recommends CPU clock 300MHz or more
USB port or a parallel port is installed in the main body, and operate.
|
Microsoft@Windows98AMeA2000(sp4 or more)AXp
|
Corresponding Model
|
Connected by TAKIKAWA's LASER DIAMETER
LDM-110A110EXA210A210CA1000A1000EXA100A100XY(100EX)
|
Communication rate
|
Difference depending on the model. An initial value is 9600bps.
|
DataBitLength
|
‚Wbits
|
StopBitLength
|
‚Pbit
|
ParityBit
|
None
|
Function
|
Measurement Value Display,Peak value displayAMeasurement value state display
Data writeing , Graph Drawing and printing function
|
Elastoring/Spray Marker
Outside Dia. Control System
- These units are to control diameter by outputting feed-back signals to extruding machine or winding machine in continuous extruding molding production line.
- Among the range, there are DAC-76A(Step delay control type), DAC-86B(PI control type) and DAC+88(Automatic starting-up type).
- There is LDM-210C that builds the control unit into the measuring instrument of the LASER DIAMETER. @
- Among the range, there is deformed material extruding control system for keeping shape of profile constant of extruding plastic or resin
Outside Dia. Control System
Model |
DAC-86B |
DAC-76A |
DAC+88 |
LDM-210C
(Dia.Control Part) |
Control
method |
P/I/SPEED
Control |
Step delay
Control |
Parameter
Control |
Selected
P/I Control or Step delay Control |
Automatic
starting-up |
NG |
NG |
OK |
NG |
Applicable
Micrometers |
All devices which have
Analog deviation output |
Only LDM-Series |
Included LDM |
Input kinds |
Error input,
Line speed input |
Error input, |
Extruder input,
Capstan input |
Line speed input |
Input isolation |
OK |
OK |
OK |
OK |
Input range
[DCV] |
Error: +/-10V
Line speed: +10V |
Error: +/-10V |
Extruder: +10V
Capstan: +10V |
Line speed: +10V |
Input impedance |
200k ohm |
200k ohm |
200k ohm |
200k ohm |
Error
gain setting |
NG |
10um/V-10mm/V
(decade steps) |
NG |
NG |
Output kinds |
Control output |
Control output |
Extruder output,
Capstan output |
Control output |
Output method |
Deviation control |
Deviation control |
Absolute control |
Deviation control |
Output isolation |
OK |
OK |
OK |
OK |
Output range |
DC+/-10V |
DC+/-10V |
DC+/-10V |
DC+10V
(Ext./Cap. each) |
Max. current |
DC+/-20mA |
DC+/-20mA |
DC+10mA
(Ext./Cap. each) |
DC+/-20mA |
Output impedance |
less than 6 ohm |
less than 6 ohm |
less than 10 ohm
(Ext./Cap. each) |
less than 6 ohm |
Output limit
setting |
OK |
OK |
OK |
OK |
Setting items |
P,I |
Alarm,P |
System data(11items)[*1]
Work data(12items) |
P,I or
P,Speed voltage,Distance |
Programing
function |
NG |
NG |
OK
(100 kinds) |
NG |
Operation button |
MANU/AUTO
/RESET |
MANU/AUTO
/RESET |
MANU/AUTO/UP/DOWN |
MANU/AUTO |
External remote input |
OK |
OK |
OK |
OK |
Pulse signal
of length |
Unnecessary |
Necessary |
Unnecessary |
Unnecessary |
Main display |
Output display
by LED bargraph |
Output display
by analog meter |
Operation state
display by LCD |
Output display
by LED bargraph |
RS-232C |
OK |
NG |
OK |
OK |
Tacho-generator
input |
NG |
OK |
NG |
NG |
Power supply |
AC100-240V 50/60Hz Free power supply |
Power
consumption |
less than 8VA |
less than 15VA |
less than 10VA |
less than 20VA |
Ambient condition |
Temperature:0-45 degree centigrade,
Humidity:30-85%(No condensation) |
Outside dimension
W * H * D[mm] |
144 * 72 * 191 |
350 * 99 * 331 |
144 * 72 * 191 |
144 * 72 * 241 |
Weight |
Approx. 1.5kg |
Approx. 3kg |
Approx. 1.7kg |
Approx. 1.8kg |
- [*1]Those data are backed up by battery, and not necessary to set for each product.
Defromed material extruding control system Specificaion
Summary |
This system is for keeping shape of profile constant through direct compensation/control of extruding machine or drawing machine by measuring in Non-contact method a discrepancy from standard value of profile to be extruded with a detecting head to be set just behind extruding machine at the time when extruding plastic or resin. |
Edge sensor |
Sensing method |
Non-contact/Infrared optical fiber sensing |
PRF-10H
PRF-40H |
Measuring range |
1mm * 20mm(PRF-10H),
4mm * 20mm(PRF-40H) |
Resolution |
+/-1um |
Accuracy |
+/-5um |
Operation temperature |
Max. 300 degree centigrade |
Outside dimension |
360(W) * 45(H) * 20(D)[mm] |
Weight |
400g |
Controller |
Deviation indicator |
Analog meter
+/-0.5mm(PRF=10H), +/-2mm(PRF-40H) |
PRF-93 |
Deviation output |
DC voltage(Range: -4V to +4V)
4V/0.5mm(PRF-10H)A4V/2mm(PRF-40H) |
High/Low limit output |
Muti-level setting available, Contact output 250V 1A |
Power supply |
AC100`240V 50/60Hz 10VA |
Outside dimention |
144(W) * 72(H) * 191(D)[mm] |
Weight |
1.5kg |
Control unit |
DAC-86B(See Spec. of DAC-86B) |
Sensor mounting metals |
Option |
PRF-93@@@@ |
PRF-10H@@@ |
PEF-40H@@@ |
TRAVERSE CONTROLLER
TRAVERSE CONTROLLER (TRC-10)
This is a device to control Traverse motion of Winding drum.
This device is to output Traverse speed voltage in proportion to its pulse
frequency number through receiving a rotation pulse of winding drum
Specifications
Type |
Traverse Controller |
Model |
TRC-10 |
Summary |
This controller can control traverse motion when widing up
cables to cable drum. Control output is proportional voltage to
widing up speed. |
Display |
Position/Setting, State(RUN/WAIT), Direction |
Data setting |
Drum width, Pitch, Stop angle, Max. speed,
Pulse rate, Output fine adjustment |
Volume setting |
Wide movement value, Frame movement value |
Pulse input |
A/B Phase(0.01 - 50kHz), Single phase pulse available,
DC+12V[Max.40mA] Power supply avaelable |
Extrenal input |
Quick feed, Wide movement, Position reset, Frame movement,
Emergency stop, Turn, Normal traverse, Reverse traverse start |
Traverse output |
Max.+/-10VDC(Resolution : 12 bits) |
Fixed voltage
output |
+/-10VDC 2 channel, DC0 - +10V 2 channel
(Adjustable by volume at rear panel) |
Contact output |
A direction, B direction
AC250V/DC30V 10A DC30V (Resistance load) |
Power supply |
AC100 - 240V 50/60Hz 5VA |
Ambient
condition |
Temperature:0 - 45degree centigrade,
Humidity:35 - 85%RH(No condensation) |
Outside
dimension |
144(W) * 72(H) * 191(D)[mm] |
Weight |
Approx. 1.5kg |
PRESET CONTROL COUNTER
Preset Control Counter (PR-06)
PR-06 is 6-digit up/down counter for production line that is
available to set Preset-1(Forecasted value) as deviation from
full value, and Preset-1 value can be controled by line speed
Specifications
Type |
Preset Control Counter |
Model |
PR-06 |
Summary |
PR-06 is 6-digit up/down counter for production line that is
available to set Preset-1(Forecasted value) as deviation from
full value, and Preset-1 value can be controled by line speed. |
Method |
Double preset type up/down counter |
Display |
6-digt 7-segment LED, Zero suppressed |
Preset-1 |
Forecasted value:4-digit setting(Setting deviation from full value), Contact/Non-contact output available |
Preset-2 |
Full value:4-digit setting, Contact/Non-contact output available |
Contact output |
DC30V/AC250V 1A(Resistance load),
Delay:Less than 20msec |
Non-contact output |
Open-collector output(Max.35V 50mA Negativ logic),
Delay:Less than 10msec |
Output function |
One shot or Hold(Cancel by reset) |
Pulse input |
A/B phase, Single phase pulse available,
Driving current:More than 5mA,
DC+12V(50mA) Power supply available |
Max. frequency |
30cps/2kcps(alternative), Duty 1:1 |
Manual reset |
From push switch on front panel(More than 50msec) |
External reset |
Short-circuited terminal(More than 50msec) |
Inhibit input |
Short-circuited terminal or 'L' level input to terminal
(Recovery time: Less than 590usec) |
Power supply |
AC100V/200V 50/60Hz 10VA |
Ambient condition |
Temperature:-10 - 45degree centigrade,
Humidity:35 - 85%RH(No condensation) |
Outside dimension |
144(W) * 72(H) * 138(D)[mm] |
Weight |
Approx. 1kg |
Reverse Detector OM Series
Reverse Detector (OM-01)
This detector can output alarm by detecting reverse motion of winding direction in winding system and can be installed on DIN rail.
A/B Phase Divider (OM-02)
This device is to obtain 1/10 and 1/100 deviding output of single phase or A/B phase input pulse and can be installed on DIN rail.
2-Channels Distributor (OM-03)
This device has 2 channel input and 5 output for each pulse input and can be installed on DIN rail.
Specifications
Type |
Reverse Detector |
Model |
OM-01 |
Summary |
This detector can output alarm by detecting reverse motion of winding direction in winding system and can be installed on DIN rail. |
Power supply |
DC+12V/0.5A(Changeable by option) |
Reverse count Setting |
3-digit digital switch |
Contact output |
1-a contact, 590ms one shot, AC240V 1A(Resistance load) |
Pulse input |
A/B phase pulse |
Max. frequency |
5kHz(Changeable by option) |
Display |
Power on LED and Reverse detecting LED |
Inhibit input |
Short-circuited terminal or 'L' level input to terminal
(DC5V/CMOS level) |
Outside dimension |
100(W) * 70(H) * 112(D)[mm], Installing on DIN rail available |
Type |
A/B Phase Divider |
Model |
OM-02 |
Summary |
This device is to obtain 1/10 and 1/100 deviding output of single phase or A/B phase input pulse and can be installed on DIN rail. |
Power supply |
DC+12V/0.5A(Changeable by option) |
Dividing ratio |
1/10 and 1/100 |
Output |
Open collector output |
Pulse input |
A/B phase pulse |
Max. frequency |
10kHz(Changeable by option) |
Single/2 phase changing |
Changing by jumper on internal PCB |
Outside dimension |
100(W) * 70(H) * 112(D)[mm], Installing on DIN rail available |
Type |
2-Channels Distributor |
Model |
OM-03 |
Summary |
This device has 2 channel input and 5 output for each pulse input and can be installed on DIN rail. |
Power supply |
DC+12V/0.5A(Changeable by option) |
Input |
2 channels(Pulled-up by 4.7kohm resistances) |
Output |
5-outputs/1-channel(Open collector output) |
Max. frequency |
10kHz(Changeable by option) |
Outside dimension |
100(W) * 70(H) * 112(D)[mm], Installing on DIN rail available |
Changeable Constant Current Source
Changeable Constant Current Source (VI-101,102)
Special power source to control brake or clutch by input voltage in production line.
Type |
Changeable Constant Current Source |
Model |
VI-101 |
VI-102 |
Summary |
Special power source to control brake or clutch by input voltage in production line. |
Input voltage |
DC 0 - +10V |
Output current |
DC0 - 1A(Changeable range:0.1 - 1A), Ripple:Max. 0.5% |
DC0 - 2A(Changeable range:0.2 - 2A), Ripple:Max. 0.5% |
Max. output voltage |
DC+25V |
DC+28V |
Withstand voltage
(in-out) |
+/-2000Vp |
Circuit type |
Serial CMOS Power transistors circuit |
Power supply |
AC200V(AC100V available by option) 50/60Hz 30VA |
AC200V(AC100V available by option) 50/60Hz 60VA |
Operation temperature |
-5 - 50 degree centigrade |
Outside dimension |
130(W) * 85(H) * 102(D)[mm] |
180(W) * 144(H) * 84(D)[mm] |
Weight |
1.0kg |
1.5kg |
Takikawa Engineering
Measuring instruments
Laser Micrometer
Scanning Units
- There are three different types of Laser Micrometers as standard type, such as Scanning Units for Single axis measuring , Orthogonal dual axes measuring and Swing type all circumference measuring.
- For measuring large diameter work pieces of more than 300mm, it can be measured by combination of 2 units of Single axis Scanning Unit.
- For applications to install emitters and receivers separately or widen their distance, Separate type can be used. Also Multi-axis measuring more than Double axes can be made by combination of Separate type Scanning Units.
- No influence to the measured value by ambient light such as the sunlight, etc.
- Measurement of high temperature objects with up to 2000 degrees centigrade is available by minor modification of the Scanning Unit.
Takikawa Engineering Common specifications |
Measuring system |
Non-contact laser scanning system |
Light source |
Semiconductor laser diode(Max. output 1mW), Red(670nm), Continuous wave class 2 |
Structure of Unit protection |
Dust protection(IP-64) |
Ambient condition |
Temperature:0-45degree centigrade,
Humidity:35-85%RH(No condensation) |
Takikawa Engineering Individual specifications |
Model |
Measuring
range
(mm) [*1] |
Measuring
accuracy
[*2] |
Resolution |
Weight |
Single axis measuring Standard type |
LDM-301H |
0.02~1 |
+/- 1um |
+/- 0.1um |
1kg |
LDM-302H |
0.05~5 |
+/-1um |
+/-0.1um |
1kg |
LDM-303H |
0.3~30 |
+/-2um |
+/-0.1um |
1kg |
LDM-304H |
0.5~90 |
+/-5um |
+/-1um |
3.5kg |
LDM-305H |
1~180 |
+/-10um |
+/-1um |
15kg |
LDM-306H |
2~300[*2] |
+/-30um |
+/-1um |
34kg |
Single axis measuring Separate type |
LDM-302H-SP |
0.05~5 |
+/-1um |
+/-0.1um |
1kg |
LDM-303H-SP |
0.3~30 |
+/-2um |
+/-0.1um |
0.9kg |
LDM-304H-SP |
0.5~90 |
+/-5um |
+/-1um |
2.5kg |
LDM-305H-SP |
1~180 |
+/-10um |
+/-1um |
11kg |
LDM-306H-SP |
2~300*2 |
+/-30um |
+/-1um |
28kg |
Orthogonal Dual axes measuring type |
LDM-302H-XY |
0.05~5 |
+/-1um |
+/-0.1um |
2kg |
LDM-303H-XY |
0.3~30 |
+/-2um |
+/-0.1um |
2kg |
LDM-304H-XY |
0.5~`90 |
+/-5um |
+/-1um |
14kg |
LDM-305H-XY |
1~180 |
+/-10um |
+/-1um |
50kg |
LDM-306H-XY |
2~300 |
+/-30um |
+/-1um |
70kg |
Swing type all circumference measuring[*3] |
LDM-303H-SP
LDM-703A |
0.3~30 |
+/-2um |
+/-0.1um |
9kg[*4] |
LDM-304H
LDM-704A |
0.5~90 |
+/-5um |
+/-1um |
27kg[*4] |
LDM-305H
LDM-705 |
1~180 |
+/-10um |
+/-1um |
60kg[*4] |
[*1]Measurement of large diameter more than several meters can be made by using 2 units of Scanning Unit
[*2]Measuring accuracy is stated on the conditions of average time more than 400 times and measurement within special measuring area.
[*3]LDM-703, LDM-704A and LDM-705 are Model No. only for Swing Mechanisms.
[*4]These weights are only for Swing Mechanisms. |
High Speed Scanning Type
Takikawa Engineering Common specifications |
Measuring system |
Non-contact laser scanning system(2000time/sec) |
Light source |
Semiconductor laser diode(Max. output 1mW), Red(670nm), Continuous wave class 2 |
Structure of Unit protection |
Dust protection(IP-64) |
Ambient condition |
Temperature:0-45degree centigrade,
Humidity:35-85%RH(No condensation) |
Takikawa Engineering Individual specifications |
Model |
Measuring
range
(mm) |
Measuring
accuracy
[*1] |
Resolution |
Weight |
Single axis measuring Standard type |
LDM-301HS |
0.03~1 |
+/-1um |
+/-0.1um |
1kg |
LDM-302HS |
0.07~5 |
+/-1um |
+/-0.1um |
1kg |
LDM-303HS |
0.3~30 |
+/-2um |
+/-0.1um |
1kg |
LDM-304HS |
0.5~90 |
+/-5um |
+/-1um |
3.5kg |
Single axis measuring Separate type |
LDM-303HS-SP |
0.3~30 |
+/-2um |
+/-0.1um |
0.9kg |
LDM-304HS-SP |
0.5~90 |
+/-5um |
+/-1um |
2.5kg |
[*1]Measuring accuracy is stated on the conditions of average time more than 400 times and measurement within special measuring area. |
- Distance between transmitter and receiver ( Separate model )
LDM-302H-SP --- 20mm Max.
LDM-303H-SP --- 400mm Max.
LDM-304H-SP --- 1000mm Max.
LDM-305H-SP --- 3500mm Max.
LDM-306H-SP --- 4000mm Max.
- High temperature measuring object - Optional remodel (Up to about 1200Ž Max. )
- transparent measuring object---Standard function of display unit
- tranceparent film width---optional remodel
|
- Cable Extention Adaptor (LDM-201,-202), to be used in case distance between a Scanning Unit and a Display Unit exceeds 30 meters.
- Dividing Adaptor (LDM-205,-206), which divides output signals from Scanning Unit.
|
Display Units
A lot of applications are available by various functions of Display Units.
- Real time measurment and Max./Min. value, Average value Display for a period.
- Average,Difference,Sum,Ratio,Flatness calculation of Multi-axis measurement
- Large diameter/Long width measuring
- Film thickness measuring
- IC-Pin Pitches measuring
- Total Control of Multi-production lines
- Cable cover(wall) thickness measuring
- Outside Diameter Control is available by Control Units
- Others
|
LDM-110 |
LDM-110EX |
LDM-1000 |
LDM-1000EX |
LDM-210 |
LDM-210C |
No. of Axes |
For Single |
Max. 2 |
Max. 5 |
Max. 3 |
For Single |
Scanning cycle |
400 times/sec |
400 times/sec |
400 times/sec |
400 times/sec |
2000 times/sec |
No. of
Averaging time |
1-2048
(16 steps) |
1-2048
(8 steps) |
1-2048(22 steps) at LDM-1000LS
1-1024(19 steps) at LDM-1000XY |
1-2048
(12 steps) |
Measuring mode |
16 kinds |
8 kinds
(X,Y axis each) |
16 kinds + Optional edges measurement
per each axis |
Optional edges measurement
per each axis |
Processing
function |
NG |
Average, Difference, Large dia. measurement, etc. |
NG |
Cable cover(Wall)
thickness
processing |
NG |
NG |
OK(by LDM-1000XY) |
NG |
Display device |
7 segment LED |
Graphic LCD |
7 segment LED |
7 segment LED |
No. of Display digit |
4-5 digits |
4-5 digits |
3-6 digits |
3-6 digits |
4-5 digits |
Processing
contents monitor |
NG |
NG |
OK |
OK |
NG |
Center position
monitor |
LED(8pcs) |
LED(8pcs)
(X,Y axis each) |
Graphic bargraph
per each axis |
LED(8pcs) per each axis |
LED(8pcs) |
LED(15pcs) |
No. of channel of
Recorder output |
1 |
1 |
1 channel per board(LDM-1000LS/XY) |
1 |
Recorder output
performance |
Max.+/-10V, Resolution 12bits(=approx.10mV/1bit),
Output impedance 100ohm(approx.),
Deviation/Absolute value switch over available |
Recorder output
gain |
1μm-1m/V(decade steps) |
0.1μm`1m/V(decade steps) |
1μm-1m/V(decade steps) |
Digital dia.
controller
connection |
OK |
OK |
NG |
NG |
OK |
NG
(Built-in Dia.Controller) |
Center value
setting |
5 digits |
5 digits |
6 digits |
6 digits |
5 digits |
High/Lo limit
tolerance setting |
4 digits |
4 digits |
6 digits |
5 digits |
5 digits |
High/Low limit
contact output |
1a contact(*2) |
1a contact(*2) per board(LDM-1000LS/XY) |
1a contact(*2) |
Contact rating: AC250V 2A(Resistance load) |
Error
contact output |
1b contact(Close when power OFF) |
1b contact(Close when power OFF)(Combined use by each board) |
1b contact(Close when power OFF) |
Contact rating: AC250V 2A(Resistance load) |
Laser remote
terminal |
OK |
OK
(X,Y common) |
OK(each LDM-1000LS board) |
OK |
Hold terminal |
OK |
OK
(X,Y,P common) |
OK(each LDM-1000LS/XY board) |
OK |
Edge monitoring
function |
OK |
OK |
OK |
OK |
OK |
Self-diagnosis
mode |
OK |
OK |
OK |
OK |
OK |
Multi-point
calibration
function |
OK |
NG |
NG |
NG |
OK |
Trigger function
(Max. meas.,
Deviation meas.,
etc.) |
NG |
NG |
OK |
OK |
NG |
Offset
function |
NG |
NG |
OK |
OK |
NG |
Zero set
function |
OK |
NG |
OK |
OK |
OK |
mm/inch
changeover
function |
NG |
NG |
OK |
OK |
NG |
Programing
function |
NG |
NG |
OK(30 kinds) |
OK(9 kinds) |
NG |
Graph display |
NG |
NG |
OK |
NG |
NG |
Serial port |
OK |
OK |
OK |
OK |
OK |
OK |
BCD output |
Option |
OK(by LDM-1000BCD) |
Option |
Cable length |
Standard 5 meters, Max. 30 meters (Extensible to 120m.max. as option) |
Power supply |
AC100-240V Free power supply 50/60Hz |
Power
consumption |
less than 11VA |
less than 14VA |
less than 15VA(only display unit)
less than 8VA(each board) |
less than 15VA |
less than 20VA |
Ambient
condition |
Temperature:0-45 degree centigrade, Humidity:35`85%RH(no condensation) |
Outside
dimension |
144(W) * 72(H) * 191(D)[mm] |
216(W) * 144(H) * 225(D)[mm] |
144(W) * 72(H) * 191(D)[mm] |
144(W) * 72(H) * 241(D)[mm] |
Weight |
Approx. 1.5kg |
Approx. 1.6kg |
Approx. 4kg (only display unit)
Approx. 280g (each board) |
Approx. 1.5kg |
Approx. 1.8kg |
- Cable Extention Adaptor (LDM-201,-202), to be used in case distance between a Scanning Unit and a Display Unit exceeds 30 meters.
- Dividing Adaptor (LDM-205,-206), which divides output signals from Scanning Unit.
- LDM-210/LDM-210C uses the detection part of the exclusive use because the scan time is different from the conventional model.
|
Takikawa Engineering Eccentricity Monitor
|
EM-303A |
EM-304A |
Components |
Measurement unit
(EM-303A) |
Measurement unit
(EM-304A) |
HF Power supply
(EM-200R-4) |
Display unit (EM-PC) |
Condition
of
objects
mesured |
Objects |
Electric cable/wire, whose core conductor shall be round and insulated. |
Finished diameter (mm) |
0.3`15[*1] |
0.8`30 |
Core diameter
(mm) |
0.1`10[*2] |
0.5`20 |
Measuring
accuracy[*3] |
Diameter : +/-0.002mm[*4]
Eccentricity : +/-0.010mm[*5] |
Diameter : +/-0.005mm
Eccentricity : +/-0.020mm[*5] |
Ambient condition |
Temperature |
5 - 40 degree centigrade |
Temperature
change
(undertaking
accuracy) |
less than 10 degrees |
Humidity |
35 - 85%RH (No condensation) |
Output |
Analog output |
Diameter deviation(Ave.,X,Y), Eccentricity(X,Y) are
-10V to +10VDC
Diameter(Ave.), Eccentricity, Eccentric angle are
0V to +10V |
RS-232C Communication |
Baud rate 1200/2400/4800/9600/19200/38400 bps |
Alarm output |
Upper and Lower limit of Diameter, Eccentricity over (MOS relay output) |
Data save |
Saving data into HDD is available |
Power
supply |
Supply voltage |
AC100V +/-10V |
Supply frequency |
50/60Hz |
Power consumption |
less than 120VA |
Earthing resistance |
less than 100 ohm |
Outside dimension
[mm] |
Measurement unit |
386(W) * 386(H) * 314(D) |
526(W) * 530(H) * 348(D) |
HF Power supply |
121(W) * 117(H) * 280(D) |
Display unit |
346(W) * 287(H) * 173(D) |
Weight |
Measurement unit |
21‚‹‚‡ |
38‚‹‚‡ |
HF Power supply |
4.5‚‹‚‡ |
Display unit |
7‚‹‚‡ |
[*1]Available upto 20mm in a specific condition.
[*2]Available upto 15mm in a specific condition.
[*3]This condition shall be applied to X-axis and Y-axis respectively.
[*4]This measuring accuracy is guaranteed when the condition that the diameter is less than 10mm and the cable/wire position shall be locating at the place within +/-10mm of its center are satisfied.
[*5]This measuring accuracy is guaranteed when the condition that the diameter is less than 10mm and the cable/wire position shall be locating at the place within +/-3mm of its center are satisfied. |
Cable Capacitance Monitor / Calibration Capacitor
- This monitor can continuously measure capacitance of a covered cable in on-line water bath, which is manufacutured by continuous extruding machine.
- Cable capacitance control is available by outputting control voltage.
- Cablibration for Cable Capacitance Monitor is available by Calibration Capacitor (Option).
Display unit |
Model |
CPM-401 |
Measuring range |
0 - 400pF/m (Expansible by option) |
Measuring accuracy |
Either larger value of +/-0.2% of reading value or +/-0.2pF/m |
Resolution |
0.1pF/m |
Sampling time |
500 times/sec |
Capacitance display |
4-digit 7-segment LED (Green) |
Deviation display |
4-digit 7-segment LED (Red)
LED Bargraph.(F.S.=selectable +/- 10 or 100pF/m) |
Target value setting |
4-digit digital switch |
High/Low limit
setting |
3-digit digital switch |
Average |
Moving average(1 - 5000 times, 1/2/5 steps) |
Zero adjustment |
Push ZERO switch on front panel and adjust at automatic |
Analog output |
Output capacitor/deviation(selectable) within +/-10VDC,
Selectable gain, Isoration type. |
High/Low limit
contact output |
Display in Red LED, 1a-contact (AC250V resistance load 2A) |
BCD output |
Option |
External
communication |
RS-232C interface |
Control method |
Proportional control |
Control output |
Max. +/-10VDC, Isoration type |
Line speed |
Max. 3000m/min |
Power supply |
AC100 - 240V Free power supply 50/60Hz 10VA |
Ambient condition |
Temperature:0 - 45 degree centigrade,
Humidity:35 -85%RH(No condensation) |
Outside dimension |
144(W) * 72(H) * 191(D)[mm] |
Weight |
Approx. 1.7kg |
Repeater unit |
Model |
CPM-101 |
Construction |
Alminium diecast (Dust & Water proof) |
Ambient temperature |
0 - 45 degree centigrade |
Outside dimension |
80(W) * 125(H) * 57(D)[mm] |
Weight |
Approx. 1.7kg |
Sensor unit |
Model |
CP-05 |
CP-09 |
CP-15 |
CP-26 |
Outside dimension |
28 * 226mm |
40 * 386mm |
60 * 656mm |
80 * 900mm |
Weight |
0.5kg |
1kg |
3kg |
6kg |
Water conductivity |
1mS/cm or less (It depends on water temperature and dissolved materials. Recommendable to use water with conductivity of 0.5mS/cm or less) |
- After purchase, tracability is available by option.
- Calibration Capacitor for CP-15/CP-26 can be prepared by option.
- Please feel free to contact us about calibration for other Capacitance Monitors.
- Please feel free to contact us about measuring method of Calibration Capacitor.@
Takikawa Engineering Running Metalwire Thermometer
name |
Runnning MetalWire Thermometer |
model |
RMT-01 |
Features |
- A portable thermometer with compact size, light weight and dry batteries used for power.
- Applicable for even small diameter of less than 0.1mm by using k-type thermocouple with small heat capacity to measure temparature of small metal wires.
- As for the maximum measurement diameter, even Φ10mm is possible.
- Accurate measurement is available due to small heat capacity of the thermocouple and small rotation friction of the pulley.
- Free from thouble of short circuit to the thermocouple caused by copper dust or the like.
- Non-contact power supply and data passing to the pulley that makes the pulley's rotation friction so small and rotation so smooth.
- A high-performance thermometer by making full use of CPU and the latest electronic technology.
- Accurate calibration is available by using a calibrator for K-type thermocouple.
|
Detection Sensor |
K-type(Alumel-chromel) thermocouple |
Temparature Measuring range |
10 ~ 250℃ |
Display |
7 segment LCD 4digits |
Display Time |
1/Sec. (once a second) |
Power |
A dry battery (size AA) x 4 and AC Adaptor |
Power
Consumption |
6V 0.4A(dry battery)
5V 0.5A(rechargeable battery)
Durable for 4 hour constant use of dry batteries
and a rechageable battery made by SANYO Electric Co.,Ltd. |
Ambient Temperature,Humidity |
0~45℃,35~85%RH(No condensation) |
Outside Demension |
Machine body : 70(W)×157.4(H)×34.5(D)[mm]
Pulley : 100mm diameter. |
Weight |
Approx.0.7kgiincluding batteriesj |
Takikawa Engineering LENGTH MEASURING COUNTERS
- * LC-2500 satisfy the cable manufacturer's demand of
pursuing accurate cable length.
- * This tester variously applied to wide speed range and conductor diameter, have belt driving unit and here not any slippage.
- * This tester is suitable device for demanding high performance and reliability at cable length measuring parts.
MODEL |
LC-1000 |
LC-2000H |
LC-2500H |
LC-3000H |
LC-3500R |
Line Center |
1000±150mm |
1000±250mm |
1000±160mm |
1000±120mm |
Machine adhesion |
Roller |
Hard Coating |
Coating Belt |
Timing Belt +Ceramic |
Coating Belt |
Measure |
Digital pulse input |
Max. Diameter |
Φ5 - 150mm |
Φ10 - 200mm |
Φ5 - 100mm |
Φ2 - 20mm |
Φ10 - 80mm |
Max. Line Speed |
100m/m |
50m/m |
100m/m |
200m/m |
40m/m |
Display |
6digits LED display |
Contact Output |
2reset contact 250V 5A resitive load |
Meter Pulse Out |
1pulse /1m x 3EA |
ACCURACY |
0.05% |
Resolution |
0.02%(1pulse 50um) |
Power Supply |
100 - 240VAC 50/60Hz |
Detector
Surface Variation Detector
- TM-series Surface Variation Detectors were designed to monitor surface variations in an object by means of emitting light to the object and detecting a difference of interrupted light volume which is affected by the variation.
- Those TM-series detectors can be used in production lines of all products, such as optical fibers, enamel, vinyl wires, communication and power cables, metal and glass rods, plastic tubes, pipes, hose, etc., which are required to detect surface variations.
- Non-contact type detection & reliable, continuous high speed detection.
- Easy operation and simple maintenance.
For Fine wire/cable |
Model |
TM-503W |
TM-1100XY |
TM-1003W |
TM-1104W |
Detecting derection |
3 |
2 |
3 |
4 |
Measuring method |
Double-slit, infrared LED projection type |
Measuring range |
0.02 - 3mm |
0.02 - 5mm |
Detecting sensitivity |
0.01 - 1mm |
Detecting accuracy |
+/-1% of max. set value |
Slit length |
6mm |
18mm |
12mm |
18mm |
Slit width |
0.1mm |
0.5mm |
Line speed[*1] |
5m/min - 2000m/min |
1m/min - 1500m/min |
Recorder output |
+/-0.2V/0.1mm |
+/-1V/0.1mm |
+/-0.5V/0.1mm |
+/-1V/0.1mm |
Alarm output |
Red LED turns on,
Relay contact output(AC250V 2A Resistance load) |
Alarm time[*2] |
0.1 sec |
0.5 sec |
0.1 sec |
0.5 sec |
Ambient temperature |
-5 - 50 degree centigrade(No condensation) |
Power supply[*3] |
DC+/-15V |
AC100V 50/60Hz |
DC+/-15V |
AC100V 50/60Hz |
Power consumption |
5VA |
10VA |
5VA |
10VA |
Outside demension
(W * H * D[mm]) |
150 * 140 * 40 |
260 * 265 * 60 |
150 * 140 * 40 |
350 * 280 * 55 |
Weight |
0.8kg |
2.5kg |
1kg |
5kg |
|
for Middle dia. wire/cable |
Model |
TM-3001W |
TM-3002W |
TM-3004W |
TM-3008W |
TM-3016W |
Detecting derection |
1 |
2 |
4 |
8 |
16 |
Detecting method |
Double-slit, infrared LED projection type |
Measuring range |
0.1 - 35mm |
Detecting sensitivity |
0.05 - 10mm |
Detecting accuracy |
+/-1% of max. set value |
Slit length |
48mm |
Slit width |
1mm |
Line speed[*1] |
1m/min - 1500m/min |
Recorder output |
+/-0.1V/0.1mm(on each axis) |
Alarm output |
Red LED turns on,
Relay contact output(AC250V 2A Resistance load) |
Alarm time[*2] |
0.5 sec |
Ambient temperature |
-5 - 50 degree centigrade(No condensation) |
Power supply[*3] |
AC100V 50/60Hz |
Power consumption |
5VA |
10VA |
10VA |
20VA |
40VA |
Outside demension
(W * H * D) |
260 * 90
* 41mm |
260 * 260
* 60mm |
370 * 335
* 60mm |
370 * 335
* 120mm |
370 * 335
* 240mm |
Weight |
1.5kg |
3kg |
6kg |
12kg |
24kg |
|
for Large dia. wire/cable/pipe |
Model |
TM-4001 |
TM-4002 |
TM-4004 |
TM-4008 |
TM-4016 |
Detecting derection |
1 |
2 |
4 |
8 |
16 |
Detecting method |
Single-slit, white tungsten lamp projection type |
Measuring range |
0.1 - 60mm |
Detecting sensitivity |
0.15 - 10mm |
Detecting accuracy |
+/-2% of max. set value |
Slit length |
70mm |
Slit width |
1.5mm |
Line speed[*1] |
1m/min - 1000m/min |
Recorder output |
+/-0.1V/0.1mm(on each axis) |
Alarm output |
Yellow or Red LED turns on |
Relay contact output (AC250V 2A Resistance load) |
Alarm time[*2] |
0.5 sec |
Ambient temperature |
-5 - 50 degree centigrade(No condensation) |
Power supply[*3] |
AC100V 50/60Hz |
Power consumption |
10VA |
20VA |
30VA |
60VA |
120VA |
Outside demension
(W * H * D) |
540 * 160
* 100mm |
630 * 560
* 160mm |
807 * 674
* 136mm |
807 * 674
* 272mm |
807 * 680
* 424mm |
Weight |
7kg |
25kg |
38kg |
76kg |
152kg |
|
For Extra. large dia. wire/cable/pipe |
Model |
TM-6004 |
TM-6008 |
TM-7003 |
TM-7009 |
TM-7012 |
Detecting derection |
4 |
8 |
3 |
9 |
12 |
Detecting method |
Single-slit, white tungsten lamp projection type |
Measuring range |
1 - 80mm |
1 - 130mm |
Detecting sensitivity |
0.2 - 10mm |
Detecting accuracy |
+/-2% of max. set value |
Slit length |
90mm |
140mm |
Slit width |
2mm |
Line speed[*1] |
0.3m/min - 500m/min |
Recorder output |
+/-0.1V/0.1mm(on each axis) |
Alarm output |
Yellow or Red LED turns on |
Relay contact output (AC250V 2A Resistance load) |
Alarm time[*2] |
0.5 sec |
Ambient temperature |
-5 - 50 degree centigrade(No condensation) |
Power supply[*3] |
AC100V 50/60Hz |
Power consumption |
30VA |
60VA |
30VA |
90VA |
120VA |
Outside demension
(W * H * D) |
720 * 660
* 153mm |
720 * 660
* 306mm |
990 * 930
* 125mm |
990 * 930
* 375mm |
990 * 930
* 500mm |
Weight |
38kg |
76kg |
40kg |
120kg |
160kg |
[*1]Applicable Line speed range varies by variation height.
[*2]HOLD output is available. (Option)
[*3]AC200V Power supply type is available. (Option)
In addition, other models for more detecting directions such as TM-6020(20 axes), and TM-7012(12 axes) and for parallel multiple line such as TM-1000S-8ch are also available |
Surface Variation Detector
TMS-1104W/TMS-01
DETECTOR |
Display unit |
Model |
TMS-1104W |
Model |
TMS-01 |
dxf format
CAD file |
Go |
dxf format
CAD file |
Go |
Detecting derection |
4 axis |
Sampling Friquency |
75KHz(4axis) |
Detection Method |
Double-slit, infrared LED projection type |
Main Display |
7segmentLED 5digit |
Detectable Outside Diameter |
φ0.02~5mm |
Sub Display |
7segmentLED 2digit |
Detecting Sensitivity |
0.02~0.999mm |
Recorder Output |
0.1mm/V |
Detecting Accuracy |
+/-10μm. set value |
Length Measurement input |
encorder input |
Slit length |
18mm |
Length Measurement power output |
DC12V Max50mA |
Slit width |
0.5mm |
Alarm Output |
Relay contact output(AC250V 2A Resistance load) |
Feeding speed[*1] |
1m/min~1000m/min |
Outside Contact input |
Reset input |
Response |
3Hz~10KHz |
RS-232C interface |
OK |
|
|
Cable length
( Between Sensor/Display ) |
5m |
|
|
Alarm Time |
0.01~0.999Sec |
Ambient Temperature |
-5 - 50 degree centigrade
(No condensation) |
Power Source |
AC90~240V 50/60Hz |
|
|
Power Consumption |
17VA |
Outside Dimension
(W×H×D[mm]) |
350×280×55 |
Outside Dimension
(W×H×D[mm]) |
144×144×210 |
Weight |
3.5kg |
Weight |
3kg |