Fuses & Fuse Holders
Drip Shield
Item Number
|
Description
|
H-J Family of Companies
CM70382457
|
CT Bushing - 37 Leads
|
H-J Family of Companies
CM70382458
|
CT Bushing - 45 Leads
|
H-J Family of Companies
CM70382402
|
CT Bushings - Small
|
Fuses and Fuse Holders
Current Limiting Fuse Centered Mounting Block
Current Limiting Fuse Holder
Expulsion Fuses and Expulsion Fuse Holders
Item Number
|
Description
|
H-J Family of Companies CM7035
|
Weak Link Fuse Series
|
H-J Family of Companies CM7038
|
Fuse Holder Series
|
H-J Family of Companies CM7038
|
Terminal Block Series
|
Bayonet Fuse Links
Bushing Anti-Tracking Kit for use on Distribution Transformer high voltage bushings in contaminated areas.
Item Number : EC7590ZA0199
Dry-Well Fuse Holders for Current Limiting Bushings
Dry-Well Fuseholders for Current Limiting Fuses
Item Number
|
KV
|
BIL
|
Description
|
H-J Family of Companies EC7559ZC8599
|
8.3
|
95
|
Non-Loadbreak
|
H-J Family of Companies EC7559ZC8499
|
15
|
125
|
Non-Loadbreak
|
H-J Family of Companies EC7559ZC8399
|
21
|
125
|
Non-Loadbreak
|
H-J Family of Companies EC7559ZC2599
|
21
|
150
|
Non-Loadbreak
|
H-J Family of Companies EC7559ZB8299
|
8.3
|
95
|
Loadbreak
|
H-J Family of Companies EC7559ZB8499
|
8.3
|
95
|
Loadbreak
|
H-J Family of Companies EC7559ZB8799
|
8.3
|
95
|
Loadbreak
|
H-J Family of Companies EC7559ZB8399
|
15
|
125
|
Loadbreak
|
H-J Family of Companies EC7559ZB8899
|
8.3
|
95
|
Loadbreak
|
H-J Family of Companies EC7509ZE0199
|
8.3
|
95
|
Submersible Non-Loadbreak
|
H-J Family of Companies EC7509ZE0299
|
15
|
125
|
Submersible Non-Loadbreak
|
H-J Family of Companies EC7509ZE0399
|
21
|
125
|
Submersible Non-Loadbreak
|
H-J Family of Companies EC7559ZE1199
|
8.3
|
95
|
Submersible Non-Loadbreak
|
H-J Family of Companies EC7559ZE1299
|
15
|
125
|
Submersible Non-Loadbreak
|
H-J Family of Companies EC7559ZE1399
|
21
|
125
|
Submersible Non-Loadbreak
|
H-J Family of Companies Expulsion Fuses
Isolation Links
Item Number
|
Description
|
EC7580ZB0299
|
Isolation Link
|
EC7580ZB0399
|
Isolation Link
|
EC7580ZB0499
|
Isolation Link
|
EC7580ZB0599
|
Isolation Link
|
EC7580ZB0699
|
Isolation Link
|
Current Limiting Fuses
- Oil Submersible Back Up Current Limiting Fuses
- Sure Guard ETP Fuses
Fuse Block Assembly
ITEM NUMBER
|
MAX RATING kV
|
CURRENT RATING rms
|
DIM. A (IN.)
|
DIM. B (IN.)
|
DIM. C (IN.)
|
GE9F59TBC040-A
|
8.3
|
40A
|
2.2
|
11.2
|
10
|
GE9F59TBC050-A
|
8.3
|
50A
|
2.2
|
11.2
|
10
|
GE9F59TBC065-A
|
8.3
|
65A
|
2.2
|
11.2
|
10
|
GE9F59TBC080-A
|
8.3
|
80A
|
2.2
|
11.2
|
10
|
GE9F59TBC100-A
|
8.3
|
100A
|
2.2
|
11.2
|
10
|
GE9F59TCC125-A
|
8.3
|
125A
|
3.3
|
11.2
|
10
|
GE9F59TCC150-A
|
8.3
|
150A
|
3.3
|
11.2
|
10
|
GE9F59TCC200-A
|
8.3
|
200A
|
3.3
|
11.2
|
10
|
GE9F59TBD040-A
|
15.5
|
40A
|
2.2
|
16.62
|
15.42
|
GE9F59TBD050-A
|
15.5
|
50A
|
2.2
|
16.62
|
15.42
|
GE9F59TBD065-A
|
15.5
|
65A
|
2.2
|
16.62
|
15.42
|
GE9F59TBD080-A
|
15.5
|
80A
|
2.2
|
16.62
|
15.42
|
GE9F59TCD100-A
|
15.5
|
100A
|
3.3
|
16.62
|
15.42
|
GE9F59TCD125-A
|
15.5
|
125A
|
3.3
|
16.62
|
15.42
|
GE9F59TCD150-A
|
15.5
|
150A
|
3.3
|
16.62
|
15.42
|
GE9F59TBE040-A
|
23
|
40A
|
2.2
|
16.62
|
15.42
|
GE9F59TBE050-A
|
23
|
50A
|
2.2
|
16.62
|
15.42
|
GE9F59TBE065-A
|
23
|
65A
|
2.2
|
16.62
|
15.42
|
*GE9F59VBD040-A
|
15.5
|
40A
|
2.2
|
11.42
|
10
|
*GE9F59VCE030-A
|
23
|
30A
|
3.3
|
11.42
|
10
|
Fuse Mounting Board Assembly
ITEM NUMBER
|
MAX RATING kV
|
CURRENT RATING rms
|
DIM. A (IN.)
|
DIM. B (IN.)
|
DIM. C (IN.)
|
GE9F59TBC040-A3
|
8.3
|
40A
|
2.2
|
11.2
|
10
|
GE9F59TBC050-A3
|
8.3
|
50A
|
2.2
|
11.2
|
10
|
GE9F59TBC065-A3
|
8.3
|
65A
|
2.2
|
11.2
|
10
|
GE9F59TBC080-A3
|
8.3
|
80A
|
2.2
|
11.2
|
10
|
GE9F59TBC100-A3
|
8.3
|
100A
|
2.2
|
11.2
|
10
|
GE9F59TCC125-A3
|
8.3
|
125A
|
3.3
|
11.2
|
10
|
GE9F59TCC150-A3
|
8.3
|
150A
|
3.3
|
11.2
|
10
|
GE9F59TCC200-A3
|
8.3
|
200A
|
3.3
|
11.2
|
10
|
GE9F59TBD040-A3
|
15.5
|
40A
|
2.2
|
16.62
|
15.42
|
GE9F59TBD050-A3
|
15.5
|
50A
|
2.2
|
16.62
|
15.42
|
GE9F59TBD065-A3
|
15.5
|
65A
|
2.2
|
16.62
|
15.42
|
GE9F59TBD080-A3
|
15.5
|
80A
|
2.2
|
16.62
|
15.42
|
GE9F59TCD100-A3
|
15.5
|
100A
|
3.3
|
16.62
|
15.42
|
GE9F59TCD125-A3
|
15.5
|
125A
|
3.3
|
16.62
|
15.42
|
GE9F59TCD150-A3
|
15.5
|
150A
|
3.3
|
16.62
|
15.42
|
GE9F59TBE040-A3
|
23
|
40A
|
2.2
|
16.62
|
15.42
|
GE9F59TBE050-A3
|
23
|
50A
|
2.2
|
16.62
|
15.42
|
GE9F59TBE065-A3
|
23
|
65A
|
2.2
|
16.62
|
15.42
|
*GE9F59VBD040-A3
|
15.5
|
40A
|
2.2
|
11.42
|
10
|
*GE9F59VCE030-A3
|
23
|
30A
|
3.3
|
11.42
|
10
|
Other Fuses
1. Capacitor Fuses
Capacitor - EJ-5/EJO-5 9F60
Description :
Backup Capacitor current-limiting fuses are designed for individual capacitor protection. The EJ-5 is designed for use indoors or inside an enclosure only. The EJO-5 can be used in any location (indoor or outdoor). The major purposes of such fusing are: (a) to protect the systems from failed capacitor units, and (b) to prevent damage to adjacent capacitors and associated equipment.
Features and Benefits :
• High interrupting capacity.
• Noiseless operation.
• Fast current-limiting operation.
• No vents or special reinforced compartments required.
Product Scope :
- From 5.5 to 9.52kV
- From 8 to 80A
2. Fuse Disconnect Switch
Fuse Disconnect Switches - EK-3/EKO-3 9F61
Description :
These devices have the additional feature of serving as disconnecting switches to isolate the equipment they protect. It should be noted that the disconnecting switches are not loadbreaking devices, therefore the circuit must be open prior to the fuse disconnection. The EKO-3 models are designed to be installed outdoors.
Product Scope :
• Indoor and outdoor models.
• From 2.75 to 38kV
• From 60 to 200 BIL (kV)
3. Fuse Supports
Fuse Supports - EK-1/EKO-1 9F61
Description :
Mountings of the non-disconnecting type are available. They are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Fuse supports can be mounted vertically or horizontally. The EKO-1 models are designed to be installed outdoors.
Product Scope :
• Indoor and outdoor models.
• From 2.75 to 38kV
• From 60 to 200 BIL (kV)
4. General Purpose Fuses
General Purpose - EJO-1 9F62
Description :
General Purpose current-limiting fuses are designed to interrupt the high-fault currents and also the low-fault currents down to approximately 1.6 times their continuous current rating. This fuse is defined in the IEEE Std C37.40 -1993 (3.1.57) as "A f capable of interrupting all currents from the rated interrupting current down to the current that causes melting of the fusible element in no less than one hour." These fuses can be used outdoors without any protecting enclosure.
Features and Benefits :
• Compact sizes
• High interrupting capacity
• Noiseless operation
• UL Listed
• Fast current-limiting operation
• No vents or special reinforced compartments required
Product Scope :
• From 5.5 to 15.5kV
• From 20 to 900A
5. Power Fuses
Power - EJ-1/EJO-1 9F60
Description :
Backup power distribution current-limiting fuses are designed not only to interrupt the high-fault currents but currents down to approximately 3 times their continuous rating. The EJO-1 models can be used outdoors without any protecting enclosure.
Features and Benefits :
- High interrupting capacity
- Noiseless operation
- Fast current-limiting operation
- No vents or special reinforced compartments required
Product Scope :
- From 0.625 to 38kV
- From 0.5 to 200A
Wildlife guards
Item Number : CM7038
Description : Wildlife Guard Series
LV circuit breakers
Low Voltage Circuit Breakers
Internal, Oil-immersed Secondary Circuit Breakers
Transformers subjected to overloading or applied on lines without overload protection should be self-protected. Self-protected distribution transformers offer a complete, unified system of overload protection. The primary means of protecting the transformer is the circuit breaker, which is designed to give adequate protection from short circuits and severe overloads
Options:
Signal Light - One of the features of the self-protected pole-type transformer is the signal light. When the transformer is thermally overloaded, the signal light will light, serving as visual evidence that an unusual overload has occurred on the transformer.
Emergency Overload - Through the use of the emergency overload lever, self-protected transformers are able to carry overloads in excess of those normally permitted by the circuit breakers. If a transformer circuit breaker has tripped and the bimetals are still at trip temperature, the use of the emergency overload lever may allow the operator to close the circuit breaker to restore service
Overload Indicator Assembly
Item Number
|
Signal Light
|
Description
|
EC7591ZB1099
|
Yes
|
Overload Switch Assembly
|
EC7591ZB1399
|
No
|
Overload Switch Assembly
|
Signal Lights
Item Number :EC7591ZE9399
Description :Signal Light Assembly
Arresters
- Low Voltage Distribution Class MOV Surge Arrester
Item Number : EC9F96DA480
Distribution Low Voltage Arresters
Distribution Under-Oil Arresters
Polymer Distribution and Riser Pole Arresters
Part Number List DOWNLOAD BROCHURE PDF
Level indicators
LIQUID LEVEL GAGES
Item Number
|
DESCRIPTION
|
INT005-001
|
STANDARD
|
INT005-004
|
SPANISH FACE PLATE
|
PRESSURE-VACUUM GAUGES
Item Number
|
FIGURE
|
DESCRIPTION
|
INT001-001K (Old #)
|
1
|
10 PSIG
|
INT001-001K-SS (New #)
|
1
|
10 PSIG
|
INT001-003K
|
2
|
75 kPa
|
INT001-001K-01
|
N/A
|
REPLACEMENT LENS
|
THERMOMETERS AND WELLS
ITEM NUMBER
|
DIM. (A)
|
DIM. (B)
|
THREAD SIZE
|
INT002-002
|
7"
|
6 13/16"
|
7/8" - 14
|
INT002-003
|
5 11/16"
|
5 1/2"
|
3/8" - 18 NPT
|
INT002-003L
|
7"
|
6 13/16"
|
3/8" - 18 NPT
|
#INT002-006
|
7"
|
6 13/16"
|
7/8" - 14
|
ITEM NUMBER
|
DIM. (A)
|
DIM. (B)
|
THREAD SIZE
|
INT003-002
|
5 1/2"
|
3 11/16"
|
3/8" - 18 NPT
|
Liquid Level Gauges
Item Number
|
DESCRIPTION
|
INT005-001
|
STANDARD
|
INT005-004
|
SPANISH FACE PLATE
|
Pressure Vacuum Gauges
Item Number
|
FIGURE
|
DESCRIPTION
|
INT001-001K (Old #)
|
1
|
10 PSIG
|
INT001-001K-SS (New #)
|
1
|
10 PSIG
|
INT001-003K
|
2
|
75 kPa
|
INT001-001K-01
|
N/A
|
REPLACEMENT LENS
|
H-J Family of Companies Thermometers and Wells
- H-J Family of Companies THERMOMETERS
ITEM NUMBER
|
DIM. (A)
|
DIM. (B)
|
THREAD SIZE
|
INT002-002
|
7"
|
6 13/16"
|
7/8" - 14
|
INT002-003
|
5 11/16"
|
5 1/2"
|
3/8" - 18 NPT
|
INT002-003L
|
7"
|
6 13/16"
|
3/8" - 18 NPT
|
#INT002-006
|
7"
|
6 13/16"
|
7/8" - 14
|
ITEM NUMBER
|
DIM. (A)
|
DIM. (B)
|
THREAD SIZE
|
INT003-002
|
5 1/2"
|
3 11/16"
|
3/8" - 18 NPT
|
Temperature indicators & controls
Oil Temperature Indicators (pdf)
Thermometers with Contacts
Thermostats (pdf)
Winding Temperature Indicators (pdf)
Protection relays
Buchholz Relays
Dehydrating air breathers
Breathers (pdf)
Pressure relief devices
Pressure Relief Valves
Seal Nut