Draw Wire
- Range 50 - 50000 mm
- Accuracy 0,05% - 0,25%
- Resolution 0,1 - 1 mm
- Output 10V, 4-20mA, A/B/Z, SSI, CAN, Par.
- Measurement through draw wire
|
|
|
Inductive Gauge LVDT
- Range 2 - 600 mm
- Accuracy 0,1% - 0,3%
- Resolution 5 - 200 µm
- Output 5V, 10V, bipolar, 4-20mA
- Measurement through free core, guided or sprung loaded push rod
|
|
|
Eddy Current Probe
- Range 0,5 - 8 mm
- Accuracy 0,25%
- Resolution 100 - 1000 nm
- Output 5V, 10V, bipolar, CAN
- Contactless measurement at metallic objects
|
|
|
Laser
- Range 0,5 - 800 mm
- Accuracy 2 - 2000 µm
- Resolution 1 - 100 µm
- Contactless through triangulation
|
|
|
Digital Magnetic Scale
- Range 50 mm - 50 m
- Accuracy 10 - 100 µm
- Resolution 0,1 - 5 µm
- Output A/B u. Ref., TTL, Vss
- Contactless through magnetic floater
|
|
|
Digital Gauge
- Range 5 - 205 mm
- Accuracy 1 - 10 µm
- Resolution 0,2 - 5 µm
- Output A/B u. Ref., TTL
- Measurement through sprung loaded push rod
|
|
|
Digital Ruler
- Range 15 - 2170 mm
- Accuracy 2 - 10 µm
- Resolution 0,1 - 5 µm
- Output A/B u. Ref., TTL, Vss
- Measurement through reading head
|
|
|
Linear Potentiometer
- Range 10 - 2000 mm
- Accuracy 0,05% - 0,2%
- Resolution k. A.
- Output potentiometrisch
- Measurement through guided/sprung loaded/slider/ring
|
|
|
Magnetostrictive
- Range 50 - 4000 mm
- Accuracy 0,02% - 0,1%
- Resolution 1 - 100 µm
- Output 10V, 4-20mA, Tacho, Start-Stop, PWM, Profibus
- Contactless through floating cursor or ring magnet
|
|
|
Ultrasonic
- Range 100 - 6000 mm
- Accuracy 0,7% - 1,5%
- Resolution 1 - 3 mm
- Output 5V, 10V, 4-20mA
- Contactless through ultrasonic sound reflection
|
|
|
Display + Control
- Multifunctional display
- Input analog/digital
- 1 - 10 channels
- Built in and external units (miller/lathe)
- Distance and velocity, comparator...
|
|
|
Angle Transmitter + Encoder
- Single and multiturn
- Analogue and digital transducer
- Solid shaft/hollow shaft
- Output A/B/Z, CAN, Profibus, 10V, 4-20mA, 1k
- Rotational measurement
|