TLS-GD2
Product Selection
Type
|
Contacts
|
Solenoid
|
Actuator Type
|
Cat. No.
|
Safety
|
Auxiliary
|
Contacts
|
Voltage
|
Conduit
|
Connector§
|
M20
|
1/2 inch NPT Adaptor
|
12-Pin M23
|
8-Pin Micro (M12)§
|
TLS-1 GD2 Power to Release
|
2 N.C.
|
1 N.O.
|
1 N.C. & 1 N.O.
|
24V AC/DC
|
—
|
440G-T27121
|
—
|
440G-T27233
|
440G-T2NBBPH-1R
|
GD2 Standard
|
440G-T27251
|
440G-T27169
|
440G-T27234
|
—
|
Fully Flex
|
440G-T27252
|
440G-T27171
|
440G-T27235
|
—
|
110V AC/DC
|
—
|
440G-T27124
|
—
|
—
|
—
|
GD2 Standard
|
440G-T27253
|
440G-T27172
|
—
|
—
|
Fully Flex
|
440G-T27254
|
440G-T27174
|
—
|
—
|
230V AC/DC
|
—
|
440G-T27123
|
—
|
—
|
—
|
TLS-2 GD2
Power to Lock
|
2 N.C.
|
1 N.O.
|
1 N.C. & 1 N.O.
|
24V AC/DC
|
—
|
440G-T27127
|
—
|
440G-T27239
|
440G-T2NBBPH-1L
|
GD2 Standard
|
440G-T27255
|
440G-T27175
|
440G-T27240
|
—
|
Fully Flex
|
440G-T27256
|
440G-T27177
|
440G-T27241
|
—
|
110V AC/DC
|
—
|
440G-T27132
|
—
|
—
|
—
|
GD2 Standard
|
440G-T27257
|
440G-T27178
|
—
|
—
|
Fully Flex
|
440G-T27258
|
440G-T27180
|
—
|
—
|
230V AC/DC
|
—
|
440G-T27129
|
—
|
—
|
—
|
TLS-3 GD2
Power to
Release
|
2 N.C.
|
1 N.O.
|
2 N.C.
|
24V AC/DC
|
—
|
440G-T27134
|
—
|
440G-T27245
|
440G-T2NBBPH-2R
|
GD2 Standard
|
440G-T27259
|
440G-T27181
|
440G-T27246
|
—
|
Fully Flex
|
440G-T27260
|
440G-T27183
|
440G-T27247
|
—
|
110V AC/DC
|
—
|
440G-T27138
|
—
|
—
|
—
|
GD2 Standard
|
440G-T27261
|
440G-T27184
|
—
|
—
|
Fully Flex
|
440G-T27262
|
440G-T27186
|
—
|
—
|
230V AC/DC
|
—
|
440G-T27136
|
—
|
—
|
—
|
TLS-1
GD2 Power to Release with
Escape Release
|
2 N.C.
|
1 N.O.
|
1 N.C. & 1 N.O.
|
24V AC/DC
|
—
|
440G-T21BNPM-1B
|
440G-T21BNPT-1B
|
440G-T21BNPL-1B
|
440G-T2NBNPH-1B
|
GD2 Standard
|
440G-T21BGPM-1B
|
440G-T21BGPT-1B
|
440G-T21BGPL-1B
|
—
|
110V AC/DC
|
—
|
440G-T21BNPM-4B
|
440G-T21BNPT-4B
|
—
|
—
|
GD2 Standard
|
440G-T21BGPM-4B
|
440G-T21BGPT-4B
|
—
|
—
|
TLS-3 GD2
Power to Release with
Escape
Release
|
2 N.C.
|
1 N.O.
|
2 N.C.
|
24V AC/DC
|
—
|
440G-T21BNPM-2B
|
440G-T21BNPT-2B
|
440G-T21BNPL-2B
|
440G-T2NBNPH-2B
|
GD2 Standard
|
440G-T21BGPM-2B
|
440G-T21BGPT-2B
|
440G-T21BGPL-2B
|
—
|
110V AC/DC
|
—
|
440G-T21BNPM-5B
|
440G-T21BNPT-5B
|
—
|
—
|
GD2 Standard
|
440G-T21BGPM-5B
|
440G-T21BGPT-5B
|
—
|
—
|
|
Recommended Logic Interfaces
Description
|
Safety Outputs
|
Auxiliary Outputs
|
Time Delay
|
Terminals
|
Reset Type
|
Power Supply
|
Cat. Page No.
|
Cat. No.
|
Single-Function Safety Relays
|
MSR127RP
|
3 N.O.
|
1 N.C.
|
—
|
Removable (Screw)
|
Monitored Manual
|
24V AC/DC
|
|
440R-N23135
|
MSR127TP
|
3 N.O.
|
1 N.C.
|
—
|
Removable (Screw)
|
Auto./Manual
|
24V AC/DC
|
|
440R-N23132
|
MSR126T
|
2 N.O.
|
None
|
—
|
Fixed
|
Auto./Manual
|
24V AC/DC
|
|
440R-N23117
|
MSR30RT
|
2 N.O. Solid State
|
1 N.O. Solid State
|
—
|
Removable
|
Auto./Manual or Monitored Manual
|
24V DC
|
|
440R-N23198
|
Specialty Safety Relays
|
MSR178
|
3 N.O.
|
2 N.C.
|
1.5 s…30 min
|
Removable
|
Automatic
|
24V AC/DC, 115V AC or 230V AC
|
|
440R-M23227
|
CU2
|
2 N.O.
|
1 N.C.
|
0.1 s…40 min
|
Fixed
|
—
|
24V AC/DC
|
|
440R-S07281
|
CU3
|
2 N.O.
|
1 N.C.
|
—
|
Fixed
|
Automatic/Manual
|
110V AC
|
|
440R-S35002
|
Modular Safety Relays
|
MSR210P Base
2 N.C. only
|
2 N.O.
|
1 N.C. and 2 PNP Solid State
|
—
|
Removable
|
Auto./Manual or Monitored Manual
|
24V DC from the base unit
|
|
440R-H23176
|
MSR220P Input Module
|
—
|
—
|
—
|
Removable
|
—
|
24V DC
|
|
440R-H23178
|
MSR310P Base
|
MSR300 Series Output Modules
|
3 PNP Solid State
|
—
|
Removable
|
Auto./Manual Monitored Manual
|
24V DC
|
|
440R-W23219
|
MSR320P Input Module
|
—
|
2 PNP Solid State
|
—
|
Removable
|
—
|
24V DC from the base unit
|
|
440R-W23218
|
|
Connection Systems
Description
|
8-Pin Micro (M12)
|
12-Wire,
12-Pin M23
|
9-Wire,
12-Pin M23§
|
Cordset
|
889D-F8AB-¬
|
889M-F12AH
|
889M-F12X9AE-¬
|
Patchcord
|
889D-F8ABDM-T
|
889M-F12AHMU
|
—
|
|
¬ Replace symbol with 2 (2 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
T Replace symbol with 1 (1 m), 2 (2 m), 3 (3 m), 5 (5 m), or 10 (10 m) for standard cable lengths.
‡ Replace symbol with 0M3, (0.3 m), 0M6 (0.6 m), 1 (1 m), 2 (2 m) or 3 (3 m) for standard lengths.
§ The 9-wire cordset can be used only with the TLS3 versions.
Note: For additional information, see Safety Connection Systems.
ML LockML Lock description a robust radial disc tumbler lock, the building block of the fortress range, offering in...