440G-L07247 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 230V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 1/2 in NPT Adapter
440G-L07248 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 110V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 1/2 in NPT Adapter
440G-L07249 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 24V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 1/2 in NPT Adapter
440G-L07253 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 230V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: M20 Conduit
440G-L07254 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 110V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: M20 Conduit
440G-L07255 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 24V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: M20 Conduit
440G-L07256 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 230V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 1/2 in NPT Adapter
440G-L07257 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 110V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 1/2 in NPT Adapter
440G-L07258 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 24V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 1/2 in NPT Adapter
440G-L07262 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 230V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: M20 Conduit
440G-L07263 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 110V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: M20 Conduit
440G-L07264 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 24V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: M20 Conduit
440G-L07298 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 24V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 12-Pin M23
440G-L07301 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 24V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 12-Pin M23
440G-L2NNSDH-38 Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 24V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 8-Pin Micro (M12)
440G-L2NNSDH-3N Guard Locking Switch - 440G Atlas 5: Solenoid Voltage: 24V AC/DC, Contacts(Safety and Aux): 2 Normally Closed, 1 Normally Open, Actuator: Standard, Conduit Entry: 8-Pin Micro (M12)