The HC200 is the first designed multiple channel heat control. The HC 200 controls multiple 230V constant resistive heaters such as quartz, ceramic, incoloy and tungsten.
This high end controller has the diagnostic feature, open heater detection, if using single or multiple heaters in a zone. The HC200 measures each zone wattage and compares this to the expected or known wattage of the zone. If the measured wattage does not equal the expected wattage an alarm is triggered. This provides the operator with critical information of single heater status or failure.
The power switch (triac) of each channel output is protected against short circuit by a super fast blow fuse located in a fuse holder. The fuse holder is located on the front of the HC block for quick accessed and exchange with out opening the HC block. This feature reduces failures, increases uptime and overall production
Custom ID code:200.102
HC200-HN-12
• 24 power outputs, 100...1000 W each (max. 2000 Watts/fuse)
• 12 fuses, FF 10 A
• 230 V phase-neutral
Custom ID code:200.302
HC200-HN-12-DI
• 24 power outputs, 100...1000 W each (max. 2000 Watts/fuse)
• 12 fuses, FF 10 A
• 230 V phase-neutral
• 4 digital control inputs (24 V dc) and 2 relay status outputs
Custom ID code:200-502
HC200-HN-12-N
• 24 power outputs, 100...1000 W each (max. 2000 Watts/fuse)
• 12 fuses, FF 10 A
• 230 V phase-neutral
• 3 screw able plug-type connectors with 4 neutral (N) clamping points each
Custom ID code:200.111
HC200-HN-24
• 24 power outputs, 100...1000 W (max. 2000 Watts/fuse
and 9100 Watts/Phase)
• 24 fuses, FF 6,3 A
• 230 V phase-neutral
Custom ID code:205.102
HC205-HN-12
• 24 power outputs, 100...1000 W each and max. 1500 W each fuse
• 12 fuses, FF 10 A
• 230 V phase-neutral
• softstart for short wave lamps
• internal inductances
• no triac protection against voltage peaks
Custom ID code:205.302
HC205-HN-12-DI
• 24 power outputs, 100...1000 W each and max. 1500 W each fuse
• 12 fuses, FF 10 A
• 230 V phase-neutral
• 4 digital control inputs (24 V dc) and 2 relay status outputs
• softstart for short wave lamps
• internal inductances
• no triac protection against voltage peaks
Custom ID code:205.502
HC205-HN-12-N
• 24 power outputs, 100...1000 W each and max. 1500 W each fuse
• 12 fuses, FF 10 A
• 230 V phase-neutral
• 3 screw able plug-type connectors with 4 neutral (N) clamping points each
• softstart for short wave lamps
• internal inductances
• no triac protection against voltage peaks
Custom ID code:205.111
HC205-HN-24
• 24 power outputs, 100...1100 W each
• 24 fuses. FF 10 A
• 230 V phase-neutral
• softstart for short wave lamps
• no internal inductances
• no triac protection against voltage pea