Pavone Sistemi Load Cells Compressio CC3
- The CC-3 load cell has been designed to meet the requirements of a wide range of applications for industrial weighing
- ATEX (option)
- Double bridge version, exit 8-conductor shielded cable (option)
- The low profile pattern and small-size dimensions require a very contained mounting space
- Good characteristics of precision and sturdiness
- The CC-3 is made of stainless steel to ensure maximum impact and overload resistance
- Temperatura compensation up to 120°C on request
- The CC-3 load cell has been designed to meet the requirements of a wide range of applications for industrial weighing
- ATEX (option)
- Double bridge version, exit 8-conductor shielded cable (option)
- The low profile pattern and small-size dimensions require a very contained mounting space
- Good characteristics of precision and sturdiness
- The CC-3 is made of stainless steel to ensure maximum impact and overload resistance
- Temperatura compensation up to 120°C on request
CAPACITY |
ØA |
B |
C |
ØD |
ØE |
F |
G |
0.1÷10t |
82 |
44 |
32 |
22 |
70 |
22 |
M8x15 |
15÷20t |
100 |
48 |
35 |
28 |
80 |
22 |
M10x15 |
25÷35t |
126 |
54 |
40 |
35 |
105 |
22 |
M12x20 |
50÷100t |
165 |
85 |
60 |
60 |
130 |
22 |
M16x20 |
200t |
200 |
85 |
60 |
85 |
165 |
22 |
M16x20 |
Electrical Connections |
+Excitation |
Red |
-Excitation |
Black |
+Signal |
Green |
-Signal |
White |
Shield |
Cable Shield |
TECHNICAL CHARACTERISTICS CC3
Rated load (RL): |
0.1÷10, 15, 20, 25, 35, 50, 100, 200 t |
Combined error: |
< ±0.05% of R.O. |
Repeatability: |
< ±0.02% of R.O. |
Creep (20 minutes): |
< ±0.02% of R.O. |
Safe overload: |
150% of R.L. |
Ultimate overload: |
300 % of R.L. |
Recommended input: |
5÷15 Vdc/Vac |
Input resistance: |
700 ±10 Ohm |
Output resistance: |
700 ±3 Ohm |
Insulation resistance: |
> 2000 M Ohm |
Rated output (R.O.): |
2.0 mV/V |
Zero balance: |
< ±1% of R.O. |
Temperature range: |
-20 ÷ +70 °C |
Compensated temperature range: |
-10 ÷ +50 °C |
Temp. effect (-10° to +50°C) on zero balance: |
0.003% of R.O./°C |
Temp. effect (-10°C to +50°C) on output: |
0.002% on output/°C |
Electrical connection: |
4 conductors shielded cable; length 5 m |
Protection Degree |
IP 68 |
CAPACITY |
A |
B |
C |
D |
E |
F |
G |
H |
0.1÷10t |
175 |
95 |
115 |
10 |
- |
150 |
14 |
M12 |
15÷20t |
200 |
102 |
160 |
10 |
35 |
12 |
17 |
M12 |
25÷35t |
250 |
132 |
185 |
12.5 |
61 |
12 |
20 |
M18 |
50÷100t |
320 |
155 |
250 |
15 |
70 |
15 |
23 |
M20 |