100 to 240VAC(50/60Hz)(Voltage fluctuation range 85 to 264VAC)
|
|
|
|
Max. -10 to +10VDC ±0.1% 10mA(output impedance 100Ω) 2pcs(each sensor head)
|
|
Object-existing(DETECTION)
|
1C photo-mos relay, Voff≤AC/DC 250V, lo≤AC/DC 100mA 2pcs(each camera)
|
Light-receiving amount lowering(LOW)
|
Photo-coupler, Vce≤DC 80V, lc≤DC 50mA 1pce(OR output for each camera)
|
|
1a photo-mos relay, Voff≤AC/DC 250V, lo≤DC 250V, lo≤AC/DC 100mA 1pce(OR output for each camera)
|
|
Light-receiving amount lowering(LOW)
|
|
Camera sensitivity changeover, photo-coupler 1 pce(common use for camera 1 & 2)
24VDC 50mA or less
|
|
6msec/12msec or less(changeover)
|
|
For communication: 9 pins D-sub connector
For sensor head: exclusive cable
|
|
7-segment LED, 4 digits × 2(analog output per camera)
Red LED 5 points(object-existing 2 points(each camera), signal-existing, light-receiving amount lowering, device trouble, each 1 point(OR per camera)
PC screen(analog, waveform, setting state etc.) available only when connecting PC
|
|
|
|
45 to 85%RH(not icing,not condensing)
|
|
20MΩ or more(between power/output contact and case by 500V megger)
|
|
AC1,500V, 1min.(between power/output contact and case)
|
|
Double amplitude 1.5mm, 10 to 55Hz, each 2 hour in X, Y and Z directions
|
|
500m/s2, each 10 times in X, Y and Z directions
|
|
|
|
|