Level Measurements
Ultrasonic Level Measurements (Compact)
Specification
Transducer: |
PVDF, PU/PC |
Housing: |
Aluminium, Plastic PBT-FR |
ViewPoint Window on Housing: |
Polycarbonate |
Standard Version: |
15...36 VDC |
Intrinsic Safety Version: |
15…30 VDC |
Power Consumption: |
Max. 22.5 mA |
Output Signal: |
4…20 mA/HART |
4-Wire Voltage: |
24 VDC ±10%, 220 VAC ±10% |
Power Consumption: |
Max. 4 VA, 2.1 W |
|
|
Download: |
|
|
|
Introduction
● Level Measurement in various Industrial Fields (especially Water Treatment Industry)
● Measurement Range: 0.25…4 m (Liquid Version)
● Process Connection: G11/2A
● Material for Transducer Housing: PVDF, PU/PC
● Process Temperature: -40…+70°C
● Process Pressure: -0.2…1bar
● Signal Output: 2/4-Wire 4…20mA/HART
Ultrasonic Level Measurements (Separate)
Specification
Display/ Programming: |
Echo Curves displayed on Lattice LCD directly, CH/ENG Menu available |
Signal Input: |
LM-USL-51X (2 Pairs) |
Output Current: |
4...20 mA(2) |
Power Supply: |
110/220 VAC ±10% 50 Hz |
Alarm Relay: |
6 Single-pole Double Throw Relays, Contact Rating |
Ambient Temperature: |
-20...+60°C |
Download: |
|
|
|
Introduction
● Level Measurements in various Industrial Fields
(especially Water Treatment Industry, Solid/ Liquid Level Measurement, Measurement of Levels,
Level Difference, Average Levels and Open Channel Flow of Solid Levels)
● Measurement Range: Liquids: 0.4…10m, 0.6...20m, 0.8...40m, 1.2...80m, 1.6...100m
Solids: 0.8...20m, 1.2...40m, 1.6...60m)
● Process Connection: G1A, M105×2
● Material for Transducer Housing: PU/PC
● Process Temperature: -40...+80°C
● Process Pressure: -0.2...1bar
● Approval (Explosion proof): Exm II T6
6.3G Radar Level Measurements
Specification
Antenna: |
PTFE, PP |
Housing: |
Aluminium, Stainless Seteel, PBT-FR |
ViewPoint Window on Housing: |
Polycarbonate |
Intrinsic Safe Version: |
24 VDC |
Standard Version: |
15…36 V DC |
4-Wire/ 2-Chamber: |
24 VDC ±10%, 220 VAC ±10% |
Power Consumption: |
< 4 VA, 2.1 W |
Output Signal: |
4...20 mA/HART |
Download: |
|
|
|
Introduction
● Level Measurement in Liquids (especially strong Erosive Liquids)
● Under easy Process Conditions and certain Temperature/ Pressure Limits
● Storage/ Process Vessels under hazardous Working Conditions
● Max Measurement Range: 30 m/ 35 m/ 70 m
● Measurement Accuracy: ±10 mm/ ±20 mm
● Antenna Material: Stainless Steel 316 L/PTFE
● Process Connection: G11/2A, PTFE Loose Flange with Stud End, Flange 316L
● Process Temperature: -40...+120°C, -40...+150°C, -40...+200°C
● Process Pressure: -1.0-3.0 bar, -1.0-16 bar, -1.0-40.0 bar
● Frequency Range: 6.3 GHz
● Signal Output: 4-20 mA/HART,2-Wire/ 4-Wire
26G Radar Level Measurements
Specification
Housing: |
Aluminium, Stainless Steel, PBT-FR |
ViewPoint Window on Housing: |
Polycarbonate |
Standard Version: |
15...36 VDC |
Intrinsic Safe Version: |
24 VDC |
4-Wire/ 2-Chamber: |
24 VDC ±10%, 220 VAC ±10% |
Power Consumption: |
< 4 VA, 2.1 W |
Output Signal: |
4...20 mA/HART |
Resolution: |
1.6 μA |
Download: |
|
|
|
Introduction
● Level Measurement in Liquids (especially Erosive Liquids)
● Under Easy Process Conditions (Solid/ Storage/ Process Vessels under Dust/ Crystallization/
Condensation)
● Measurement Range: 10 m/ 15 m/ 30 m/ 70 m
● Measurement Accuracy: ±5 mm/ ±3 mm/ ±15 mm
● Antenna Material: Stainless Steel/ PVDF/ PTFE
● Process Connection: G11/2A, G11/2A/11/2NPT, Thread, Flange and Universal Joint
● Process Temperature: -40...+130°C
● Process Pressure: -1.0-3.0 bar, -1.0-40 bar, -1.0-1.6 bar, Standard Atmosphere
● Frequency Range: 26 GHz
● Signal Output: 2-Wire/ 4-Wire 4…20 mA/HART
Level MeasurementsElco industrial automation,Level Measurements,Ultrasonic Level Measurements,Radar Level Measurements
Electronic Flow SensorsElco industrial automation,Electronic Flow Sensors FS602,flow-sensors-fs604,Electronic Flow Sensors
Sensors,Safety Products,Encoders,Linear Position Sensors,Sensors,System Products,Relays,Barriers,Level Measurements,Process Sensors